Product
High performance multi-function vector inverter VF-TS1 series 3-phase 200V seriesHandling Company
Daido Japan Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | AC power fluctuation range | Applicable motor capacity (kW) Heavy load | Applicable motor capacity (kW) Standard load | Box size code | Cooling method | Design compliant with safety regulations | Input current (A) Heavy load | Input current (A) Standard load | Output frequency range (Hz) | Power supply (V,Hz) | Protective structure | Rated output capacity (kVA) Heavy load | Rated output capacity (kVA) Standard load | Rated output current (A) Heavy load | Rated output current (A) Standard load | Rated output voltage (V) | Rated overload current (A) Heavy load | Rated overload current (A) Standard load | Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VF-TS1-20040B/N |
Available upon quote | 170~264V 50/60Hz / ±5% | 0.4 | 0.75 | Case2 | Natural cooling | UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 | 5 | 5 | 0.1~600.00Hz | Three phase 200~240V 50/60Hz | IP20 | 1.1 | 1.6 | 3 | 4.2 | Three-phase 200~240V (corresponds to input voltage) | 150%/1 minute | 120%/1 minute | 3 | |
VF-TS1-20075B/N |
Available upon quote | 170~264V 50/60Hz / ±5% | 0.75 | 1.5 | Case2 | Natural cooling | UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 | 6 | 8.8 | 0.1~600.00Hz | Three phase 200~240V 50/60Hz | IP20 | 1.9 | 2.9 | 5 | 7.5 | Three-phase 200~240V (corresponds to input voltage) | 150%/1 minute | 120%/1 minute | 3 | |
VF-TS1-20150B/N |
Available upon quote | 170~264V 50/60Hz / ±5% | 1.5 | 2.2 | Case2 | Forced air cooling | UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 | 10 | 12 | 0.1~600.00Hz | Three phase 200~240V 50/60Hz | IP20 | 3 | 3.8 | 8 | 10 | Three-phase 200~240V (corresponds to input voltage) | 150%/1 minute | 120%/1 minute | 3 | |
VF-TS1-20220B/N |
Available upon quote | 170~264V 50/60Hz / ±5% | 2.2 | 3.7 | Case2 | Forced air cooling | UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 | 14 | 18 | 0.1~600.00Hz | Three phase 200~240V 50/60Hz | IP20 | 4.2 | 5.8 | 11 | 15.2 | Three-phase 200~240V (corresponds to input voltage) | 150%/1 minute | 120%/1 minute | 3 | |
VF-TS1-20370B/N |
Available upon quote | 170~264V 50/60Hz / ±5% | 3.7 | 5.5 | Case2 | Forced air cooling | UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 | 18 | 26 | 0.1~600.00Hz | Three phase 200~240V 50/60Hz | IP20 | 6.5 | 8.4 | 17 | Twenty two | Three-phase 200~240V (corresponds to input voltage) | 150%/1 minute | 120%/1 minute | 3 | |
VF-TS1-20550B/N |
Available upon quote | 170~264V 50/60Hz / ±5% | 5.5 | 7.5 | Case2 | Forced air cooling | UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 | 30 | 41 | 0.1~600.00Hz | Three phase 200~240V 50/60Hz | IP20 | 9.5 | 12 | Twenty five | 31 | Three-phase 200~240V (corresponds to input voltage) | 150%/1 minute | 120%/1 minute | 3 | |
VF-TS1-20750B/N |
Available upon quote | 170~264V 50/60Hz / ±5% | 7.5 | 11 | Case3 | Forced air cooling | UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 | 40 | 55 | 0.1~600.00Hz | Three phase 200~240V 50/60Hz | IP20 | 13 | 16 | 33 | 41 | Three-phase 200~240V (corresponds to input voltage) | 150%/1 minute | 120%/1 minute | 5.4 | |
VF-TS1-21100B/N |
Available upon quote | 170~264V 50/60Hz / ±5% | 11 | 15 | Case3 | Forced air cooling | UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 | 60 | 66 | 0.1~600.00Hz | Three phase 200~240V 50/60Hz | IP20 | 18 | Twenty two | 46 | 58 | Three-phase 200~240V (corresponds to input voltage) | 150%/1 minute | 120%/1 minute | 5.7 | |
VF-TS1-21500B/N |
Available upon quote | 170~264V 50/60Hz / ±5% | 15 | 18.5 | Case4 | Forced air cooling | UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 | 69 | 85 | 0.1~600.00Hz | Three phase 200~240V 50/60Hz | IP20 | Twenty three | 28 | 60 | 74 | Three-phase 200~240V (corresponds to input voltage) | 150%/1 minute | 120%/1 minute | 12.4 | |
VF-TS1-201850B/N |
Available upon quote | 170~264V 50/60Hz / ±5% | 18.5 | Twenty two | Case4 | Forced air cooling | UL508C, CSA C22.2 No.14-05, EN61800-3, EN61800-5-1 | 85 | 103 | 0.1~600.00Hz | Three phase 200~240V 50/60Hz | IP20 | 28 | 34 | 74 | 90 | Three-phase 200~240V (corresponds to input voltage) | 150%/1 minute | 120%/1 minute | 13.1 |
Click on the part number for more information about each product