Power conditioner for solar power generation (FRT compatible model) DISOLA POWERHandling Company
DAIHEN CorporationCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Noise (at rated output) | Remote output control function | Operable voltage range V | Grid protection element | DC input Rated input voltage V | Structure Insulation method | Structure Approximate mass kg | Structure Dimensions mm (WxDxH) | Structure Cooling method | External communication method | Islanding detection active method | Islanding detection passive method | Usage environment Altitude | Operating environment Ambient humidity | Operating environment Ambient temperature | Usage environment Usage location | AC output phase number | AC output Maximum conversion efficiency/Euro efficiency | AC output Rated conversion efficiency/Euro efficiency | AC output rated frequency (Hz) | AC output Rated output current | AC output Rated output voltage | AC output power factor setting range | AC output Rated output capacity | Recorder function | FRT requirements |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
P250JFL1-A01 |
Available upon quote |
76dB or less (1m away from the center of the front) [Reference value] |
Supported by microserver |
DC310~700 (When connected to negative terminal: DC310V~600V) |
Overvoltage (OV), Undervoltage (UV), Frequency rise (OF), Frequency fall (UF) |
DC350 |
Transformerless (requires a dedicated external isolation transformer) |
1,500 |
1,720x1,390x2,090 |
Forced air cooling |
Ethernet |
Frequency shift method |
Frequency change rate detection method |
Less than 1,000m |
30~90% (no condensation) |
-10~45℃ |
Indoor (for outdoor installation, an optional dedicated delivery cabinet is required) |
Three-phase three-wire system |
98.4% (excluding auxiliary equipment loss) /98.1% (excluding auxiliary equipment loss) |
97.3%/97.0% |
50/60 (grid-connected operation range within ±1%) |
AC687A |
AC210V (within grid-connected operation range +5%/-10%) |
0.85~1.00 (0.01 step, can be changed to 0.80~1.00 range upon request) |
250kW/294kVA (power factor 0.85, at rated voltage) [250kW/313kVA (power factor 0.80, at rated voltage) |
Yes |
Apply FRT requirements based on grid connection assumption (JEAC9701-2012) |
|
P333JFL1-A01 |
Available upon quote |
76dB or less (1m away from the center of the front) [Reference value] |
Supported by microserver |
DC310~700 (When connected to negative terminal: DC310V~600V) |
Overvoltage (OV), Undervoltage (UV), Frequency rise (OF), Frequency fall (UF) |
DC350 |
Transformerless (requires a dedicated external isolation transformer) |
1,500 |
1,720x1,390x2,090 |
Forced air cooling |
Ethernet |
Frequency shift method |
Frequency change rate detection method |
Less than 1,000m |
30~90% (no condensation) |
-10~45℃ |
Indoor (for outdoor installation, an optional dedicated delivery cabinet is required) |
Three-phase three-wire system |
98.4% (excluding auxiliary equipment loss) /98.1% (excluding auxiliary equipment loss) |
97.3%/97.0% |
50/60 (grid-connected operation range within ±1%) |
AC916A |
AC210V (within grid-connected operation range +5%/-10%) |
0.85~1.00 (0.01 step, can be changed to 0.80~1.00 range upon request) |
333kW |
Yes |
Apply FRT requirements based on grid connection assumption (JEAC9701-2012) |
|
P500JFL1-A02 |
Available upon quote |
76dB or less (1m away from the center of the front) [Reference value] |
Supported by microserver |
DC310~700 (When connected to negative terminal: DC310V~600V) |
Overvoltage (OV), Undervoltage (UV), Frequency rise (OF), Frequency fall (UF) |
DC350 |
Transformerless (requires a dedicated external isolation transformer) |
2,000 |
2,220x1,390x2,090 |
Forced air cooling |
Ethernet |
Frequency shift method |
Frequency change rate detection method |
Less than 1,000m |
30~90% (no condensation) |
-10~45℃ |
Indoor (for outdoor installation, an optional dedicated delivery cabinet is required) |
Three-phase three-wire system |
98.4% (excluding auxiliary equipment loss) /98.1% (excluding auxiliary equipment loss) |
97.5%/97.2% |
50/60 (grid-connected operation range within ±1%) |
AC1,375A |
AC210V (within grid-connected operation range +5%/-10%) |
0.85~1.00 (0.01 step, can be changed to 0.80~1.00 range upon request) |
500kW |
Yes |
Apply FRT requirements based on grid connection assumption (JEAC9701-2012) |