Communication SPD (for communication/signal) HF series-ASG-HF5S
Communication SPD (for communication/signal) HF series-Showden Co., Ltd.

Communication SPD (for communication/signal) HF series
Showden Co., Ltd.


About This Product

■Summary The ASG series is used in combination with an ASG-SPD unit with fault indication and a dedicated power supply unit/alarm unit (and surge counter unit). This is an SPD failure monitoring system that transmits the SPD failure status from the SPD installation location (on-site) to a remote monitoring system. ■Fault display function By connecting the dedicated power supply unit and alarm unit, the SPD failure status can be displayed on the front LED lamp. Additionally, faults can be output via contact and can be sent to a distant monitoring system. ■Excellent protection circuit mechanism We offer protection circuit types suitable for the circuits to be protected (communications, signals, instrumentation, etc.). In addition, the fault contact output circuit and power input circuit (alarm unit) are equipped with protection circuits as standard, so there is no need to install a separate SPD for the alarm circuit or SPD for the power circuit. ■Complete range of anti-ground noise countermeasure products ASZ-Z series (noise-resistant connection) and ASG-HF type are available as anti-ground noise countermeasure products. ■Features ・The number of protection fibers per SPD is large, contributing to space saving (4 to 5 cores) ・Compliant with JISC5381-21 categories C2 and D1 - Standard protection circuit for instrumentation and signal SPDs, suitable for weak current signals up to DC200mA. ・Equipped with GDT between grounding, ABD between lines, and line resistance, making it especially excellent for protection between lines. ・It has the feature of not allowing high frequency noise such as inverter noise generated between the signal line and the ground to pass through the line. ■Notes - If the withstand voltage to ground of the device to be protected is particularly low (for example, if there is a low voltage circuit such as an IC between the device and the ground), we recommend the HS series. ・If there is a risk of the SPD malfunctioning due to ground-to-ground noise occurring in the communication or signal line to be protected, we recommend the HF series. ■Failure display ・Normal: LED (red) off ・During deterioration/failure: LED (red) lights up ■Alarm contact output ・Contact terminal: ASG-AL terminal A, B, C ・Contact specifications: 1C contact ・Contact rating: AC220V 1A, DC110V 0.5A ■Connection terminal M3 screw terminal (for round crimp terminal M3 slim) Maximum width of compatible round crimp terminal: 6.0 mm or less ■Applicable wire ・Single wire: 0.35~1.82mm2 ・Twisted wire: 0.2~2.63mm2 ・AWG: 26 to 14 wires are crimped to M3 crimp terminals (M3 slim for stranded wire 2mm2) and wired.

  • Product

    Communication SPD (for communication/signal) HF series

Share this product


330+ people viewing

Last viewed: 7 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

4 Models of Communication SPD (for communication/signal) HF series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Anti-ground noise countermeasures DC operating voltage V1mA between ground DC operating voltage V1mA line to line DC resistance Impulse durability category C2 between ground Impulse durability category C2 between lines Insertion loss Instrumentation signal 4-20mA DC24V Instrumentation signal 4-20mA DC48V Instrumentation signal Anemometer AC35V or less Instrumentation signal Load cell DC24V Instrumentation signal Pyranometer DC10V or less Instrumentation signal Voltage pulse Sensin pulse DC24V Instrumentation signal Voltage pulse Sensin pulse DC48V Low voltage signal Semiconductor protection Photocoupler DC5V or less Low voltage signal semiconductor protection photocoupler DC12V Low voltage signal semiconductor protection photocoupler DC24V Maximum continuous working voltage Uc Number of protection hearts Protection mode Shield-to-ground Protection mode between ground Protection mode between lines Purpose Rated current Rated voltage Signal RS485/RS422 DC12V Signal RS485/RS422 DC5V Transmission frequency band (110Ω) Voltage protection level (Up) between earth Voltage protection level (Up) between lines
Communication SPD (for communication/signal) HF series-Part Number-ASG-HF5S

ASG-HF5S

Available upon quote Ground noise countermeasure product DC230V±20% DC10V±10% 4.7Ω±10% (1 wire) 8/20μs 10kA 8/20μs 4kA 1.0dB or less - - - - - - - - - DC5.5V 4 cores + shield Between terminal 5 (shield) and terminal 6 Between terminals 1, 2, 3, 4 and 6 (ground) Between terminals 1, 2, 3, 4 RS232C, RS485 (5V system), weak electric signal DC/AC 200mA DC5V - DC~5MHz 500V or less 70V or less
Communication SPD (for communication/signal) HF series-Part Number-ASG-HF12S

ASG-HF12S

Available upon quote Ground noise countermeasure product DC230V±20% DC19V±10% 4.7Ω±10% (1 wire) 8/20μs 10kA 8/20μs 4kA 1.0dB or less - - - - - - - - - DC13.5V 4 cores + shield Between terminal 5 (shield) and terminal 6 Between terminals 1, 2, 3, 4 and 6 (ground) Between terminals 1, 2, 3, 4 RS485 (12V system), weak electric signal DC/AC 200mA DC12V - DC~5MHz 500V or less 75V or less
Communication SPD (for communication/signal) HF series-Part Number-ASG-HF24S

ASG-HF24S

Available upon quote Ground noise countermeasure product DC230V±20% DC34V±10% 4.7Ω±10% (1 wire) 8/20μs 10kA 8/20μs 4kA 1.0dB or less - - - - - DC27V 4 cores + shield Between terminal 5 (shield) and terminal 6 Between terminals 1, 2, 3, 4 and 6 (ground) Between terminals 1, 2, 3, 4 4-20mA (24V system), weak electric signal DC/AC 200mA DC24V - - DC~5MHz 500V or less 90V or less
Communication SPD (for communication/signal) HF series-Part Number-ASG-HF48S

ASG-HF48S

Available upon quote Ground noise countermeasure product DC230V±20% DC67V±10% 4.7Ω±10% (1 wire) 8/20μs 10kA 8/20μs 4kA 1.0dB or less - - - - - - - DC54V 4 cores + shield Between terminal 5 (shield) and terminal 6 Between terminals 1, 2, 3, 4 and 6 (ground) Between terminals 1, 2, 3, 4 4-20mA (48V system), 10-50mA DC/AC 200mA DC48V - - DC~5MHz 500V or less 125V or less

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Showden Co., Ltd.


View more products of Showden Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree