Product
Communication SPD (for communication/signal) Z seriesHandling Company
Showden Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Anti-ground noise countermeasures | DC operating voltage V1mA between ground | DC operating voltage V1mA line to line | DC resistance | Failure display | Impulse durability category C2 between ground | Impulse durability category C2 between lines | Impulse durability category D1 between ground | Impulse limit voltage between ground | Impulse limit voltage between lines | Insertion loss | Maximum continuous working voltage Uc | Number of protection hearts | Protection mode Shield-to-ground | Protection mode between ground | Protection mode between lines | Purpose | Rated current | Rated voltage | Relay contact control power supply (2A or less) DC110V | Relay contact control power supply (2A or less) DC12V | Relay contact control power supply (2A or less) DC24V | Relay contact control power supply AC100V 200V | Relay contact control power supply DC48V, AC24V | Speaker line AC100V 200V | Thermocouple/side temperature resistance potentiometer DC24V | Transmission frequency band (110Ω) | Voltage protection level (Up) between earth | Voltage protection level (Up) between lines | Voltage pulse Sensin pulse AC100V 200V |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ASG-Z12S |
Available upon quote | Compatible with noise-resistant connections | DC19V+10%-14% Noise-resistant connection: DC230V±20% | DC19V+10%-14% | 0.1Ω or less | Normal: LED (red) goes off Deterioration/failure: LED (red) lights up | 8/20μs 4kA | 8/20μs 4kA | 10/350μs 0.5kA | 90V or less | 100V or less | 1.0dB or less | DC14V | 4 cores + shield | Normal connection: between terminal 5 (shield) and terminal 6, noise-resistant connection: only supports grounding at both ends of the shield and connects to terminal 5 (ground) | Normal connection: between terminals 1, 2, 3, 4 to terminal 6 (ground), noise-resistant connection: between terminals 1, 2, 3, 4 and terminal 6 (common) to terminal 5 (ground) | Normal connection: between terminals 1, 2, 3, 4, noise-resistant connection: between terminals 1, 2, 3, 4 and terminal 6 (common) | DC12V or less Contact/control line | DC/AC 2A | DC12V | - | ◎ | - | - | - | - | - | DC~5MHz | 110V or less Noise-resistant connection: 500V or less | 150V or less | - | |
ASG-Z24S |
Available upon quote | Compatible with noise-resistant connections | DC40V+10%-14% Noise resistant connection: DC230V±20% | DC40V+10%-14% | 0.1Ω or less | Normal: LED (red) goes off Deterioration/failure: LED (red) lights up | 8/20μs 4kA | 8/20μs 4kA | 10/350μs 0.5kA | 150V or less | 160V or less | 1.0dB or less | DC31V | 4 cores + shield | Normal connection: between terminal 5 (shield) and terminal 6, noise-resistant connection: only supports grounding at both ends of the shield and connects to terminal 5 (ground) | Normal connection: between terminals 1, 2, 3, 4 to terminal 6 (ground), noise-resistant connection: between terminals 1, 2, 3, 4 and terminal 6 (common) to terminal 5 (ground) | Normal connection: between terminals 1, 2, 3, 4, noise-resistant connection: between terminals 1, 2, 3, 4 and terminal 6 (common) | DC24V or less Contact/control line | DC/AC 2A | DC24V | - | - | ◎ | - | - | - | - | DC~5MHz | 180V or less Noise-resistant connection: 500V or less | 220V or less | - | |
ASG-Z48S |
Available upon quote | Compatible with noise-resistant connections | DC82V+10%-14% Noise resistant connection: DC230V±20% | DC82V+10%-14% | 0.1Ω or less | Normal: LED (red) goes off Deterioration/failure: LED (red) lights up | 8/20μs 10kA | 8/20μs 4kA | 10/350μs 1kA | 200V or less | 200V or less | 1.0dB or less | DC60V | 4 cores + shield | Normal connection: between terminal 5 (shield) and terminal 6, noise-resistant connection: only supports grounding at both ends of the shield and connects to terminal 5 (ground) | Normal connection: between terminals 1, 2, 3, 4 to terminal 6 (ground), noise-resistant connection: between terminals 1, 2, 3, 4 and terminal 6 (common) to terminal 5 (ground) | Normal connection: between terminals 1, 2, 3, 4, noise-resistant connection: between terminals 1, 2, 3, 4 and terminal 6 (common) | DC48V, AC24V contacts/control wires, thermocouples, resistance temperature detectors for DC voltage signals, potentiometers | DC/AC 2A | DC48V | - | - | - | - | ◎ | - | ◎ | DC~5MHz | 300V or less Noise-resistant connection: 500V or less | 240V or less | - | |
ASG-Z100S |
Available upon quote | Compatible with noise-resistant connections | DC150V+10%-14% Noise resistant connection: DC230V±20% | DC150V+10%-14% | 0.1Ω or less | Normal: LED (red) goes off Deterioration/failure: LED (red) lights up | 8/20μs 10kA | 8/20μs 4kA | 10/350μs 1kA | 300V or less | 300V or less | 1.0dB or less | DC125V | 4 cores + shield | Normal connection: between terminal 5 (shield) and terminal 6, noise-resistant connection: only supports grounding at both ends of the shield and connects to terminal 5 (ground) | Normal connection: between terminals 1, 2, 3, 4 to terminal 6 (ground), noise-resistant connection: between terminals 1, 2, 3, 4 and terminal 6 (common) to terminal 5 (ground) | Normal connection: between terminals 1, 2, 3, 4, noise-resistant connection: between terminals 1, 2, 3, 4 and terminal 6 (common) | DC110V contact/control line | DC/AC 2A | DC110V | ◎ | - | - | - | - | - | - | DC~5MHz | 450V or less Noise-resistant connection: 500V or less | 360V or less | - | |
ASG-Z350S |
Available upon quote | Compatible with noise-resistant connections | DC470V+10%-14% Noise resistant connection: DC230V±20% | DC470V+10%-14% | 0.1Ω or less | Normal: LED (red) goes off Deterioration/failure: LED (red) lights up | 8/20μs 10kA | 8/20μs 4kA | 10/350μs 0.5kA | 900V or less | 900V or less | 1.0dB or less | AC275V DC350V *When making noise-resistant connections with ASG-Z350S, Uc should be AC140V/DC170V. (Noise-resistant connection is not possible when used at AC200V) | 4 cores + shield | Normal connection: between terminal 5 (shield) and terminal 6, noise-resistant connection: only supports grounding at both ends of the shield and connects to terminal 5 (ground) | Normal connection: between terminals 1, 2, 3, 4 to terminal 6 (ground), noise-resistant connection: between terminals 1, 2, 3, 4 and terminal 6 (common) to terminal 5 (ground) | Normal connection: between terminals 1, 2, 3, 4, noise-resistant connection: between terminals 1, 2, 3, 4 and terminal 6 (common) | AC100V/200V contacts/control wires for broadcasting (for speakers) | DC/AC 2A | AC100V AC200V *When making noise-resistant connections with ASG-Z350S, Uc should be AC140V/DC170V. (Noise-resistant connection is not possible when used at AC200V) | - | - | - | ◎ | - | ◎ | - | DC~5MHz | 1,200V or less Noise-resistant connection: 500V or less | 1,000V or less | ◎ |
Click on the part number for more information about each product