Power supply SPD VAL-MS seriesHandling Company
Showden Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Voltage protection level Up N-PE | Voltage protection level Up L-N | Protection mode | Applicable wire | No alarm contact | With alarm contact | Test standards | Exam class | Temperature/humidity | Structure | Maximum continuous working voltage Uc | Maximum discharge current Imax N-PE | Maximum discharge current Imax L-N | Failure display | Recommended wire | Connection terminal | Specified SPD separator Short circuit current 100kA or less | Specified SPD separator Required quantity | Rated voltage | External dimensions (mm) | Installation location | Installation method | Nominal discharge current In N-PE | Nominal discharge current In L-N |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VAL-MS 60ST |
Available upon quote |
0.55kV |
0.55kV |
For 1 pole |
3.5mm2~14mm2 |
VAL-MS-BE |
VAL-MS-BE/FM |
JIS C 5381-11 |
Class II |
Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less |
Plugin |
AC75V (DC100V) |
40kA |
40kA |
Normal: No display During failure: Red |
Line side 5.5mm2 or more Ground side 8mm2 or more |
Plug-in terminal |
FDS-20kA-NB (φ14x51mm) /485201 |
1 set |
AC60V (DC80V) |
17.5×90×66 |
Indoors or inside the panel |
Rail mounting (35mm width) |
15kA |
15kA |
|
VAL-MS 120ST |
Available upon quote |
0.9kV |
0.9kV |
For 1 pole |
3.5mm2~14mm2 |
VAL-MS-BE |
VAL-MS-BE/FM |
JIS C 5381-11 |
Class II |
Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less |
Plugin |
AC150V (DC205V) |
40kA |
40kA |
Normal: No display During failure: Red |
Line side 5.5mm2 or more Ground side 8mm2 or more |
Plug-in terminal |
FDS-20kA-NB (φ14x51mm) /485201 |
1 set |
AC120V |
17.5×90×66 |
Indoors or inside the panel |
Rail mounting (35mm width) |
20kA |
20kA |
|
VAL-MS 230ST |
Available upon quote |
1.35kV |
1.35kV |
For 1 pole |
3.5mm2~14mm2 |
VAL-MS-BE |
VAL-MS-BE/FM |
JIS C 5381-11 |
Class II |
Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less |
Plugin |
AC275V (DC355V) |
40kA |
40kA |
Normal: No display During failure: Red |
Line side 5.5mm2 or more Ground side 8mm2 or more |
Plug-in terminal |
FDS-20kA-NB (φ14x51mm) /485201 |
1 set |
AC230V |
17.5×90×66 |
Indoors or inside the panel |
Rail mounting (35mm width) |
20kA |
20kA |
|
VAL-MS 400ST |
Available upon quote |
2.2kV |
2.2kV |
For 1 pole |
3.5mm2~14mm2 |
VAL-MS-BE |
VAL-MS-BE/FM |
JIS C 5381-11 |
Class II |
Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less |
Plugin |
AC440V (DC585V) |
40kA |
40kA |
Normal: No display During failure: Red |
Line side 5.5mm2 or more Ground side 8mm2 or more |
Plug-in terminal |
BLA060, Pa60, AFa60 |
1 set |
AC400V |
17.5×90×66 |
Indoors or inside the panel |
Rail mounting (35mm width) |
20kA |
20kA |
|
VAL-MS 500ST |
Available upon quote |
2.8kV |
2.8kV |
For 1 pole |
3.5mm2~14mm2 |
VAL-MS-BE |
VAL-MS-BE/FM |
JIS C 5381-11 |
Class II |
Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less |
Plugin |
AC600V (DC600V) |
30kA |
30kA |
Normal: No display During failure: Red |
Line side 5.5mm2 or more Ground side 8mm2 or more |
Plug-in terminal |
BLA060, Pa60, AFa60 |
1 set |
AC500V |
17.5×90×66 |
Indoors or inside the panel |
Rail mounting (35mm width) |
15kA |
15kA |