Product
Power supply SPD VAL-MS seriesHandling Company
Showden Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Applicable wire | Connection terminal | Exam class | External dimensions (mm) | Failure display | Installation location | Installation method | Maximum continuous working voltage Uc | Maximum discharge current Imax L-N | Maximum discharge current Imax N-PE | No alarm contact | Nominal discharge current In L-N | Nominal discharge current In N-PE | Protection mode | Rated voltage | Recommended wire | Specified SPD separator Required quantity | Specified SPD separator Short circuit current 100kA or less | Structure | Temperature/humidity | Test standards | Voltage protection level Up L-N | Voltage protection level Up N-PE | With alarm contact |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VAL-MS 60ST |
Available upon quote | 3.5mm2~14mm2 | Plug-in terminal | Class II | 17.5×90×66 | Normal: No display During failure: Red | Indoors or inside the panel | Rail mounting (35mm width) | AC75V (DC100V) | 40kA | 40kA | VAL-MS-BE | 15kA | 15kA | For 1 pole | AC60V (DC80V) | Line side 5.5mm2 or more Ground side 8mm2 or more | 1 set | FDS-20kA-NB (φ14x51mm) /485201 | Plugin | Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less | JIS C 5381-11 | 0.55kV | 0.55kV | VAL-MS-BE/FM | |
VAL-MS 120ST |
Available upon quote | 3.5mm2~14mm2 | Plug-in terminal | Class II | 17.5×90×66 | Normal: No display During failure: Red | Indoors or inside the panel | Rail mounting (35mm width) | AC150V (DC205V) | 40kA | 40kA | VAL-MS-BE | 20kA | 20kA | For 1 pole | AC120V | Line side 5.5mm2 or more Ground side 8mm2 or more | 1 set | FDS-20kA-NB (φ14x51mm) /485201 | Plugin | Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less | JIS C 5381-11 | 0.9kV | 0.9kV | VAL-MS-BE/FM | |
VAL-MS 230ST |
Available upon quote | 3.5mm2~14mm2 | Plug-in terminal | Class II | 17.5×90×66 | Normal: No display During failure: Red | Indoors or inside the panel | Rail mounting (35mm width) | AC275V (DC355V) | 40kA | 40kA | VAL-MS-BE | 20kA | 20kA | For 1 pole | AC230V | Line side 5.5mm2 or more Ground side 8mm2 or more | 1 set | FDS-20kA-NB (φ14x51mm) /485201 | Plugin | Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less | JIS C 5381-11 | 1.35kV | 1.35kV | VAL-MS-BE/FM | |
VAL-MS 400ST |
Available upon quote | 3.5mm2~14mm2 | Plug-in terminal | Class II | 17.5×90×66 | Normal: No display During failure: Red | Indoors or inside the panel | Rail mounting (35mm width) | AC440V (DC585V) | 40kA | 40kA | VAL-MS-BE | 20kA | 20kA | For 1 pole | AC400V | Line side 5.5mm2 or more Ground side 8mm2 or more | 1 set | BLA060, Pa60, AFa60 | Plugin | Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less | JIS C 5381-11 | 2.2kV | 2.2kV | VAL-MS-BE/FM | |
VAL-MS 500ST |
Available upon quote | 3.5mm2~14mm2 | Plug-in terminal | Class II | 17.5×90×66 | Normal: No display During failure: Red | Indoors or inside the panel | Rail mounting (35mm width) | AC600V (DC600V) | 30kA | 30kA | VAL-MS-BE | 15kA | 15kA | For 1 pole | AC500V | Line side 5.5mm2 or more Ground side 8mm2 or more | 1 set | BLA060, Pa60, AFa60 | Plugin | Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less | JIS C 5381-11 | 2.8kV | 2.8kV | VAL-MS-BE/FM |
Click on the part number for more information about each product