Power supply SPD AGN-2 series-AGN-222DA
Power supply SPD AGN-2 series-Showden Co., Ltd.

Power supply SPD AGN-2 series
Showden Co., Ltd.

Showden Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

117.8hours


About This Product

■Built-in SPD separator eliminates the need for external SPD separator

The AGN-2 series has a built-in SPD separator with a breaking rating of AC220V 80kA inside the SPD plug, eliminating the need for an external SPD separator. As a result, space can be saved.

■Features

・Compatible with low voltage SPD class II of public construction standard specifications ・With alarm contact

■Plug-in type with high maintainability

This is a plug-in type consisting of an SPD plug and a base. Equipped with a mechanism to prevent incorrect insertion of the SPD plug and a mechanism to prevent it from coming off, improving reliability.

■Can also be connected to the primary side of an earth leakage breaker

Annex K of JIS C 5381-12:2014 stipulates that in TT systems (including Japanese power distribution systems), when connecting an SPD to the primary side of an earth leakage breaker, a voltage switching element such as a spark gap, GDT, etc. It is described that it is implemented. The AGN-4 series can be connected to the primary side of an earth leakage breaker without any problems by mounting a GDT (gas-filled discharge tube) between N and E.

■Electrical failure display and electrical alarm contact

Fault indicators and alarm contacts are electrical. The LED (green) lights up when the failure is normal and turns off when the SPD fails or there is a power outage. For electrical fault indicators, the LED will also turn off when the specified SPD separator operates (fuse blows) or if you forget to insert the external SPD separator (fuse). The alarm contact is output from the alarm contact terminal (ALM), and between c and a is a contact output (normal: OPEN, abnormal: CLOSE), and between b and c is a b contact output (normal: CLOSE, abnormal: OPEN). The advantage of electrical alarm contacts is that they not only issue an alarm in the event of an SPD failure, but also provide alarm contact output even when the SPD plug is not installed. Therefore, in the unlikely event that the SPD is not installed, it is possible to remotely monitor the situation where the SPD's overvoltage limiting function cannot be achieved. Note that the above function will perform alarm contact output even when no voltage is applied to the SPD (during a power outage), so if you do not need the alarm contact output from the SPD that occurs during power outage work, you can use the alarm contact output from the SPD during power outage work. We recommend adding a circuit to disable the output.

  • Product

    Power supply SPD AGN-2 series

Share this product


300+ people viewing

Last viewed: 3 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

2 Models of Power supply SPD AGN-2 series

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Protection mode Test standards Exam class Structure Maximum continuous working voltage Uc Voltage switching device to ground (GDT) Single phase 3 wire neutral wire grounding 100V/200V TOV on low pressure side Three-phase 4-wire Y connection, neutral point grounding 100V/173V Three-phase three-wire delta connection one-wire grounding 200V SPD separator Single phase 2 wire neutral point grounding 200V Single phase 2 wire 1 wire grounding 200V Single phase 2 wire 1 wire grounding 100V
Power supply SPD AGN-2 series-Part Number-AGN-222DA

AGN-222DA

Available upon quote

L-L, L-E

JIS C 5381-11

Class II

Plugin

AC280V

Yes

-

Endure

- -

Built-in (AC220V 80kA)

Power supply SPD AGN-2 series-Part Number-AGN-223DA

AGN-223DA

Available upon quote

L-L, L-E

JIS C 5381-11

Class II

Plugin

AC280V

Yes

Endure

Built-in (AC220V 80kA)

- - -

Click on the part number for more information about each product

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Lightning Arresters Products

Other products of Showden Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Showden Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

117.8hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree