Product
Power supply SPD AGN-4 seriesHandling Company
Showden Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Applicable circuit 3-phase 3-wire Y connection Neutral point grounding 415V | Applicable circuit 3-phase 3-wire Δ connection 1-wire grounding 200V | Applicable circuit Single phase 2 wire 1 wire grounding 100V | Applicable circuit Single phase 2 wire 1 wire grounding 200V | Applicable circuit Single phase 2 wire Neutral point grounding 200V | Applicable circuit Single phase 3 wire Neutral wire grounding 100V/200V | Exam class | Maximum continuous working voltage Uc | Protection mode | SPD separator | Structure | TOV on low pressure side | Test standards | Three-phase 4-wire Y connection, neutral point grounding 100V/173V | Three-phase 4-wire Y connection, neutral point grounding 240V/415V | Type | Voltage switching device to ground (GDT) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AGN-421SA |
Available upon quote | - | - | ○ | ○ | - | - | Class I Class II | AC280V | L-E, L-N, N~E | External | Plugin | Endure | JIS C 5381-11 | - | - | Single SPD / With alarm contact | Yes | |
AGN-422SA |
Available upon quote | - | ○ | ○*Applicable when the ground phase (N phase) is unknown. | ○*Applicable when the ground phase (N phase) is unknown. | ○ | ○ | Class I Class II | AC280V | L-E, L-N, N~E | External | Plugin | Endure | JIS C 5381-11 | - | - | Single SPD / With alarm contact | Yes | |
AGN-423SA |
Available upon quote | - | ○*The line is written as L, the ground phase as N, and the ground as E. | - | - | - | ○*Applicable when the ground phase (N phase) is unknown. | Class I Class II | AC280V | L-E, L-N, N~E | External | Plugin | Endure | JIS C 5381-11 | ○ | - | Single SPD / With alarm contact | Yes | |
AGN-444SA |
Available upon quote | ○ | - | - | - | - | - | Class I Class II | AC460V | L-E, L-N, N~E | External | Plugin | Endure | JIS C 5381-11 | - | ○ | Single SPD / With alarm contact | Yes | |
AGN-421S |
Available upon quote | - | - | ○ | ○ | - | - | Class I Class II | AC280V | L-E, L-N, N~E | External | Plugin | Endure | JIS C 5381-11 | - | - | Single SPD / No alarm contact | Yes | |
AGN-422S |
Available upon quote | - | ○ | ○*Applicable when the ground phase (N phase) is unknown. | ○*Applicable when the ground phase (N phase) is unknown. | ○ | ○ | Class I Class II | AC280V | L-E, L-N, N~E | External | Plugin | Endure | JIS C 5381-11 | - | - | Single SPD / No alarm contact | Yes | |
AGN-423S |
Available upon quote | - | ○*The line is written as L, the ground phase as N, and the ground as E. | - | - | - | ○*Applicable when the ground phase (N phase) is unknown. | Class I Class II | AC280V | L-E, L-N, N~E | External | Plugin | Endure | JIS C 5381-11 | ○ | - | Single SPD / No alarm contact | Yes | |
AGN-444S |
Available upon quote | ○ | - | - | - | - | - | Class I Class II | AC460V | L-E, L-N, N~E | External | Plugin | Endure | JIS C 5381-11 | - | ○ | Single SPD / No alarm contact | Yes | |
AGN-421SA-F |
Available upon quote | - | - | ○ | ○ | - | - | Class I Class II | AC280V | L-E, L-N, N~E | External | Plugin | Endure | JIS C 5381-11 | - | - | Set format of SPD and SPD separator / with alarm contact | Yes | |
AGN-422SA-F |
Available upon quote | - | ○ | ○*Applicable when the ground phase (N phase) is unknown. | ○*Applicable when the ground phase (N phase) is unknown. | ○ | ○ | Class I Class II | AC280V | L-E, L-N, N~E | External | Plugin | Endure | JIS C 5381-11 | - | - | Set format of SPD and SPD separator / with alarm contact | Yes |
Click on the part number for more information about each product