All Categories
History
Response Rate
100.0%
Response Time
117.8hours
Product
Power supply SPD FLT-SEC seriesHandling Company
Showden Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Voltage protection level Up N-PE | Voltage protection level Up L-PE | Voltage protection level Up L-N | Protection mode | Applicable wire | Alarm contact | Test standards | Exam class | Follow current breaking rating N-PE | Follow-on current breaking rating between L-N | Temperature/humidity | Structure | Maximum continuous working voltage Uc | Failure display | Recommended wire | Connection terminal | Specified SPD separator Short circuit current 100kA or less | Specified SPD separator Required quantity | Nominal discharge current In N-PE | Nominal discharge current In L-N | Three-phase 4-wire Y connection Neutral point grounding 240V/415V | Three-phase 4-wire Y connection, neutral point grounding 100V/173V | Three-phase three-wire Y connection, neutral point grounding 415V | Impulse discharge current between N-PE | Impulse discharge current between L-N | Single phase 3 wire neutral wire grounding 100V/200V | Single phase 2 wire neutral point grounding 200V | Three-phase three-wire delta connection one-wire grounding 200V | Single phase 2 wire 1 wire grounding 200V | Single phase 2 wire 1 wire grounding 100V |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FLT-SEC-P-T1-1C-350/25-FM |
Available upon quote | - | - |
1.5kV |
L-N |
5.5mm2~22mm2 |
Mechanical |
JIS C 5381-11 |
Class I/Class II |
100A |
50kA |
Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less |
Plugin |
AC350V |
Normal: Green When faulty: Red |
Line side 8mm2 Ground side 14mm2 or more |
Plug-in terminal |
S201312/US221M (with alarm contact) US221 (without alarm contact) |
1 set |
- |
25kA |
●3 units |
●3 units |
●3 units |
- |
25kA |
●2 units |
●2 units |
●2 units |
●1 unit |
●1 unit |
|
FLT-SEC-P-T1-1C-264/50-FM |
Available upon quote | - | - |
2.5kV |
L-N |
5.5mm2~22mm2 |
Mechanical |
JIS C 5381-11 |
Class I/Class II |
100A |
50kA |
Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less |
Plugin |
AC264V |
Normal: Green When faulty: Red |
Line side 8mm2 Ground side 14mm2 or more |
Plug-in terminal |
S201312/US221M (with alarm contact) US221 (without alarm contact) |
1 set |
- |
50kA |
- |
●3 units |
- | - |
50kA |
●2 units |
●2 units |
●2 units |
●1 unit |
●1 unit |
|
FLT-SEC-P-T1-N/PE-350/100-FM |
Available upon quote |
1.5kV |
- | - |
N-PE |
5.5mm2~22mm2 |
Mechanical |
JIS C 5381-11 |
Class I/Class II |
100A |
- |
Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less |
Plugin |
AC350V |
Normal: Green When faulty: Red |
Line side 8mm2 Ground side 14mm2 or more |
Plug-in terminal |
- | - |
100kA |
- |
●1 unit |
●1 unit |
●1 unit |
100kA |
- |
●1 unit |
●1 unit |
●1 unit |
●1 unit |
●1 unit |
|
FLT-SEC-T1+T2-1S-350/25-FM |
Available upon quote |
1.5kV |
2.2kV |
1.5kV |
L-N・N-PE・L-PE |
5.5mm2~22mm2 |
Mechanical |
JIS C 5381-11 |
Class I/Class II |
100A |
25kA |
Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less |
Plugin |
AC350V |
Normal: Green When faulty: Red |
Line side 8mm2 Ground side 14mm2 or more |
Plug-in terminal |
S201312/US221M (with alarm contact) US221 (without alarm contact) |
1 set |
100kA |
25kA |
●3 units |
●3 units |
●3 units |
100kA |
25kA |
- | - | - |
●1 unit |
●1 unit |
|
FLT-SEC-T1+T2-2S-350/25-FM |
Available upon quote |
1.5kV |
2.2kV |
1.5kV |
L-N・N-PE・L-PE |
5.5mm2~22mm2 |
Mechanical |
JIS C 5381-11 |
Class I/Class II |
100A |
25kA |
Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less |
Plugin |
AC350V |
Normal: Green When faulty: Red |
Line side 8mm2 Ground side 14mm2 or more |
Plug-in terminal |
S201312/US221M (with alarm contact) US221 (without alarm contact) |
2 sets |
100kA |
25kA |
- | - | - |
100kA |
25kA |
●1 unit |
●1 unit |
●1 unit |
- | - | |
FLT-SEC-T1+T2-3S-350/25-FM |
Available upon quote |
1.5kV |
2.2kV |
1.5kV |
L-N・N-PE・L-PE |
5.5mm2~22mm2 |
Mechanical |
JIS C 5381-11 |
Class I/Class II |
100A |
25kA |
Operating and storage temperature: -40℃~+80℃ Relative humidity: 95% or less |
Plugin |
AC350V |
Normal: Green When faulty: Red |
Line side 8mm2 Ground side 14mm2 or more |
Plug-in terminal |
S201312/US221M (with alarm contact) US221 (without alarm contact) |
3 sets |
100kA |
25kA |
●1 unit |
●1 unit |
●1 unit |
100kA |
25kA |
- | - | - | - | - |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time