Power supply SPD AFD-S series-AFD-S12A-L
Power supply SPD AFD-S series-AFD-S12A-LN
Power supply SPD AFD-S series-AFD-S14A-L
Power supply SPD AFD-S series-AFD-S14A-LN
Power supply SPD AFD-S series-AFD-S12A-LN (when combined)
Power supply SPD AFD-S series-AFD-S12A-LL
Power supply SPD AFD-S series-AFD-S12A-LLN
Power supply SPD AFD-S series-Showden Co., Ltd.

Power supply SPD AFD-S series
Showden Co., Ltd.


About This Product

■Built-in separator saves space and reduces wiring man-hours SPD Separator (Current Fuse) No external SPD separator required. This saves space and reduces wiring man-hours. ■Safety plug-in that allows safe SPD plug replacement The plug removal lever allows you to safely remove the SPD plug without having to bring your hands near the live parts. It also provides IP20 electric shock protection even when the plug is removed. ■Reduction of wiring man-hours with screw-up terminal block The use of a screw-up terminal block with a fall-prevention mechanism that eliminates the need to remove the terminal cover reduces wiring work. If screw terminal marking is required, this can be done by removing the transparent cover. ■Fault display, alarm contact output Fault indicators and fault contacts are reliable mechanical types. The fault contact outputs when the SPD fails and when the SPD plug is not installed. ■Safety considering Japan's TOV (temporary overvoltage) In addition to the TOV values ​​specified in JIS C 5381-11, we also conduct tests using TOV values ​​that occur due to accidents in Japan's power supply system to confirm safety. This Japanese TOV will be added at the next JIS revision. ■Adopts advanced safety shutoff technology SITS® The newly designed thermal separator built into the SPD has significantly improved heat isolation performance due to the heat generated when the protective component (MOV: varistor) fails. This makes it possible to separate the MOV from the main power supply line when the temperature rises before the MOV suffers a short-circuit failure (deterioration state) in "additional tests to simulate SPD failure modes" stipulated in JIS C 5381-11. is. In addition, by cooperating with the built-in SPD separator (current fuse with high breaking capacity) and thermal separator, the SPD alone can interrupt everything from leakage currents to large short-circuit currents. This function eliminates the risk of fire in the event of SPD failure. ■Compliant with public building construction standard specifications and building equipment design standards This product complies with the Standard Specifications for Public Construction Works (Reiwa 4th Edition) and is compliant with "When a low-voltage SPD has a built-in separator" as stated in the Building Equipment Design Standards (Reiwa 3rd Edition). ■Notes ・JIS C 5381-11 (Compatible with Class I) - An earth bar is included with the union type. *Other model numbers are available.

  • Product

    Power supply SPD AFD-S series

Share this product


670+ people viewing

Last viewed: 7 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Power supply SPD AFD-S series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Alarm contact Applicable circuit Applicable voltage Earth bar (for SPD connection) Format Impulse current Iimp Maximum continuous working voltage Uc Nominal discharge current In Protection mode Rated short circuit current ISCCR Temporary overvoltage caused by a failure in the low-voltage system Temporary overvoltage caused by a fault in the high-voltage system Test standards Total discharge current ITotal Voltage protection level up
Power supply SPD AFD-S series-Part Number-AFD-S12A-L

AFD-S12A-L

Available upon quote - - For AC100V/200V - Single format - - - L-E - - - - - -
Power supply SPD AFD-S series-Part Number-AFD-S12A-LN

AFD-S12A-LN

Available upon quote - - For AC100V/200V - Single format - - - L-E, N-E - - - - - -
Power supply SPD AFD-S series-Part Number-AFD-S14A-L

AFD-S14A-L

Available upon quote - - For AC400V - Single format - - - L-E - - - - - -
Power supply SPD AFD-S series-Part Number-AFD-S14A-LN

AFD-S14A-LN

Available upon quote - - For AC400V - Single format - - - L-E, N-E - - - - - -
Power supply SPD AFD-S series-Part Number-AFD-S12A-LN (when combined)

AFD-S12A-LN (when combined)

Available upon quote Yes Single phase 2 wire 100V (grounded phase included) - - Format when combined 12.5kA L-L: AC280V L-E: AC250V N-E: AC255V 20kA Between L-E, between N-E AC440V 100kA L-E: Withstands AC330V, L-N: Withstands AC330V L-E: Withstands AC820V, L-N: Withstands AC600V JIS C 5381-11 25kA L-E: 1.4kV or less, N-E: 1.4kV or less
Power supply SPD AFD-S series-Part Number-AFD-S12A-LL

AFD-S12A-LL

Available upon quote Yes Single-phase 2-wire 100V, 200V (grounding phase not specified and non-grounding) - For 2 poles Format when combined 12.5kA L-L: AC280V L-E: AC250V N-E: AC255V 20kA Between L-E AC440V 100kA L-E: Withstands AC330V L-E: Withstands AC820V JIS C 5381-11 25kA L-E: 1.4kV or less
Power supply SPD AFD-S series-Part Number-AFD-S12A-LLN

AFD-S12A-LLN

Available upon quote Yes Single-phase 3-wire 100V/200V (neutral phase grounding), 3-phase 3-wire 200V (1-phase grounding) - For 2 poles Format when combined 12.5kA L-L: AC280V L-E: AC250V N-E: AC255V 20kA Between L-E, between N-E AC440V 100kA L-E: Withstands AC330V, L-N: Withstands AC330V L-E: Withstands AC820V, L-N: Withstands AC600V JIS C 5381-11 37.5kA L-E: 1.4kV or less, N-E: 1.4kV or less
Power supply SPD AFD-S series-Part Number-AFD-S12A-LLL

AFD-S12A-LLL

Available upon quote Yes 3-phase 3-wire 200V (grounded phase not specified and ungrounded) - For 3 poles Format when combined 12.5kA L-L: AC280V L-E: AC250V N-E: AC255V 20kA Between L-E AC440V 100kA L-E: Withstands AC330V L-E: Withstands AC820V JIS C 5381-11 37.5kA L-E: 1.4kV or less
Power supply SPD AFD-S series-Part Number-AFD-S12A-LLLN

AFD-S12A-LLLN

Available upon quote Yes Three-phase 4-wire 100V/173V (neutral phase grounding) - For 3 poles Format when combined 12.5kA L-L: AC280V L-E: AC250V N-E: AC255V 20kA Between L-E, between N-E AC440V 100kA L-E: Withstands AC330V, L-N: Withstands AC330V L-E: Withstands AC820V, L-N: Withstands AC600V JIS C 5381-11 50kA L-E: 1.4kV or less, N-E: 1.4kV or less
Power supply SPD AFD-S series-Part Number-AFD-S14A-LLL

AFD-S14A-LLL

Available upon quote Yes 3-phase 3-wire 400V (neutral phase grounded and ungrounded) - For 3 poles Format when combined 12.5kA L-L: AC600V L-E: AC350V N-E: AC255V 20kA Between L-E AC440V 100kA L-E: Withstands AC600V L-E: AC885V safe failure JIS C 5381-11 37.5kA L-E: 1.8kV or less

Click on the part number for more information about each product