Product
Power supply SPD AFD-S seriesHandling Company
Showden Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Alarm contact | Applicable circuit | Applicable voltage | Earth bar (for SPD connection) | Format | Impulse current Iimp | Maximum continuous working voltage Uc | Nominal discharge current In | Protection mode | Rated short circuit current ISCCR | Temporary overvoltage caused by a failure in the low-voltage system | Temporary overvoltage caused by a fault in the high-voltage system | Test standards | Total discharge current ITotal | Voltage protection level up |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AFD-S12A-L |
Available upon quote | - | - | For AC100V/200V | - | Single format | - | - | - | L-E | - | - | - | - | - | - | |
AFD-S12A-LN |
Available upon quote | - | - | For AC100V/200V | - | Single format | - | - | - | L-E, N-E | - | - | - | - | - | - | |
AFD-S14A-L |
Available upon quote | - | - | For AC400V | - | Single format | - | - | - | L-E | - | - | - | - | - | - | |
AFD-S14A-LN |
Available upon quote | - | - | For AC400V | - | Single format | - | - | - | L-E, N-E | - | - | - | - | - | - | |
AFD-S12A-LN (when combined) |
Available upon quote | Yes | Single phase 2 wire 100V (grounded phase included) | - | - | Format when combined | 12.5kA | L-L: AC280V L-E: AC250V N-E: AC255V | 20kA | Between L-E, between N-E | AC440V 100kA | L-E: Withstands AC330V, L-N: Withstands AC330V | L-E: Withstands AC820V, L-N: Withstands AC600V | JIS C 5381-11 | 25kA | L-E: 1.4kV or less, N-E: 1.4kV or less | |
AFD-S12A-LL |
Available upon quote | Yes | Single-phase 2-wire 100V, 200V (grounding phase not specified and non-grounding) | - | For 2 poles | Format when combined | 12.5kA | L-L: AC280V L-E: AC250V N-E: AC255V | 20kA | Between L-E | AC440V 100kA | L-E: Withstands AC330V | L-E: Withstands AC820V | JIS C 5381-11 | 25kA | L-E: 1.4kV or less | |
AFD-S12A-LLN |
Available upon quote | Yes | Single-phase 3-wire 100V/200V (neutral phase grounding), 3-phase 3-wire 200V (1-phase grounding) | - | For 2 poles | Format when combined | 12.5kA | L-L: AC280V L-E: AC250V N-E: AC255V | 20kA | Between L-E, between N-E | AC440V 100kA | L-E: Withstands AC330V, L-N: Withstands AC330V | L-E: Withstands AC820V, L-N: Withstands AC600V | JIS C 5381-11 | 37.5kA | L-E: 1.4kV or less, N-E: 1.4kV or less | |
AFD-S12A-LLL |
Available upon quote | Yes | 3-phase 3-wire 200V (grounded phase not specified and ungrounded) | - | For 3 poles | Format when combined | 12.5kA | L-L: AC280V L-E: AC250V N-E: AC255V | 20kA | Between L-E | AC440V 100kA | L-E: Withstands AC330V | L-E: Withstands AC820V | JIS C 5381-11 | 37.5kA | L-E: 1.4kV or less | |
AFD-S12A-LLLN |
Available upon quote | Yes | Three-phase 4-wire 100V/173V (neutral phase grounding) | - | For 3 poles | Format when combined | 12.5kA | L-L: AC280V L-E: AC250V N-E: AC255V | 20kA | Between L-E, between N-E | AC440V 100kA | L-E: Withstands AC330V, L-N: Withstands AC330V | L-E: Withstands AC820V, L-N: Withstands AC600V | JIS C 5381-11 | 50kA | L-E: 1.4kV or less, N-E: 1.4kV or less | |
AFD-S14A-LLL |
Available upon quote | Yes | 3-phase 3-wire 400V (neutral phase grounded and ungrounded) | - | For 3 poles | Format when combined | 12.5kA | L-L: AC600V L-E: AC350V N-E: AC255V | 20kA | Between L-E | AC440V 100kA | L-E: Withstands AC600V | L-E: AC885V safe failure | JIS C 5381-11 | 37.5kA | L-E: 1.8kV or less |
Click on the part number for more information about each product