All Categories
History
Response Rate
100.0%
Response Time
139.2hours
Product
Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)Handling Company
Front Co., Ltd.Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Explosion-proof | Piping connections | Mass | Setting pressure gauge | Number of mixed components | Mixed gas components | Flow control needle valve | Flow rate accuracy | Operation axis rotation speed display | Exterior structure | Pressure gauge | Flow rate setting range for each flow path (N2 gas) | Stop valve for each flow path | Inlet pressure | Operating temperature range | Float type flow meter | Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
LMX2-J-A2 |
Available upon quote |
Not explosion-proof (It is treated as a safety device for explosion-proof purposes.) |
Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.) |
Approx. 1.5kg (1 channel) |
200kPa full scale (recommended set pressure: 50~150kPa) |
Individual (flow rate setting) ~desired number |
Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed |
Our company's needle valve Super Needle (SNPA series equivalent) |
When using a float flowmeter: ±2% (full scale) |
Yes |
Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment) |
- |
Approx. 1mL/min~Maximum approx. 50L/min (at 100kPa setting) |
PISCO ball valve |
Max 0.8MPa |
5℃~50℃ |
Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.) |
LMX2 series atmospheric pressure/analog pressure gauge type |
![]() |
LMX2-N-A2 |
Available upon quote |
Not explosion-proof (It is treated as a safety device for explosion-proof purposes.) |
Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.) |
Approx. 1.5kg (1 channel) |
200kPa full scale (recommended set pressure: 50~150kPa) |
Individual (flow rate setting) ~desired number |
Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed |
Our company's needle valve Super Needle (SNPA series equivalent) |
When using a float flowmeter: ±2% (full scale) |
Nothing |
Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment) |
- |
Approx. 1mL/min~Maximum approx. 50L/min (at 100kPa setting) |
PISCO ball valve |
Max 0.8MPa |
5℃~50℃ |
Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.) |
LMX2 series atmospheric pressure/analog pressure gauge type |
![]() |
LMX2-J-A4 |
Available upon quote |
Not explosion-proof (It is treated as a safety device for explosion-proof purposes.) |
Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.) |
Approx. 1.5kg (1 channel) |
400kPa full scale (recommended set pressure: 100~300kPa) |
Individual (flow rate setting) ~desired number |
Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed |
Our company's needle valve Super Needle (SNPA series equivalent) |
When using a float flowmeter: ±2% (full scale) |
Yes |
Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment) |
- |
Approx. 1mL/min~Maximum approx. 50L/min (at 100kPa setting) |
PISCO ball valve |
Max 0.8MPa |
5℃~50℃ |
Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.) |
LMX2 series atmospheric pressure/analog pressure gauge type |
![]() |
LMX2-N-A4 |
Available upon quote |
Not explosion-proof (It is treated as a safety device for explosion-proof purposes.) |
Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.) |
Approx. 1.5kg (1 channel) |
400kPa full scale (recommended set pressure: 100~300kPa) |
Individual (flow rate setting) ~desired number |
Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed |
Our company's needle valve Super Needle (SNPA series equivalent) |
When using a float flowmeter: ±2% (full scale) |
Nothing |
Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment) |
- |
Approx. 1mL/min~Maximum approx. 50L/min (at 100kPa setting) |
PISCO ball valve |
Max 0.8MPa |
5℃~50℃ |
Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.) |
LMX2 series atmospheric pressure/analog pressure gauge type |
![]() |
LMX2-J-A7 |
Available upon quote |
Not explosion-proof (It is treated as a safety device for explosion-proof purposes.) |
Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.) |
Approx. 1.5kg (1 channel) |
700kPa full scale (recommended set pressure: 200~500kPa) |
Individual (flow rate setting) ~desired number |
Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed |
Our company's needle valve Super Needle (SNPA series equivalent) |
When using a float flowmeter: ±2% (full scale) |
Yes |
Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment) |
- |
Approx. 2mL/min~Maximum approx. 50L/min (at 200kPa setting) |
PISCO ball valve |
Max 0.8MPa |
5℃~50℃ |
Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.) |
LMX2 series atmospheric pressure/analog pressure gauge type |
![]() |
LMX2-N-A7 |
Available upon quote |
Not explosion-proof (It is treated as a safety device for explosion-proof purposes.) |
Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.) |
Approx. 1.5kg (1 channel) |
700kPa full scale (recommended set pressure: 200~500kPa) |
Individual (flow rate setting) ~desired number |
Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed |
Our company's needle valve Super Needle (SNPA series equivalent) |
When using a float flowmeter: ±2% (full scale) |
Nothing |
Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment) |
- |
Approx. 2mL/min~Maximum approx. 50L/min (at 200kPa setting) |
PISCO ball valve |
Max 0.8MPa |
5℃~50℃ |
Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.) |
LMX2 series atmospheric pressure/analog pressure gauge type |
![]() |
LMX2-J-D2 |
Available upon quote |
Not compatible (Please use in non-explosion-proof areas.) |
Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.) |
Approx. 1.5kg (1 channel) |
30kPa~99.9kPa (The display limit of the pressure gauge is 99.9kPa.) |
Individual (flow rate setting) ~desired number |
Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed |
Our company's needle valve Super Needle (SNPA series equivalent) |
When using a float flowmeter: ±2% (full scale) |
Yes |
Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment) |
Panasonic Electric Works SUNX DP-101Z |
At 90kPa setting: Approx. 1mL/min ~ Maximum approx. 50L/min |
PISCO ball valve |
Max 0.8MPa |
5℃~50℃ |
Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.) |
LMX2 series Atmospheric pressure/digital pressure gauge type |
![]() |
LMX2-N-D2 |
Available upon quote |
Not compatible (Please use in non-explosion-proof areas.) |
Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.) |
Approx. 1.5kg (1 channel) |
30kPa~99.9kPa (The display limit of the pressure gauge is 99.9kPa.) |
Individual (flow rate setting) ~desired number |
Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed |
Our company's needle valve Super Needle (SNPA series equivalent) |
When using a float flowmeter: ±2% (full scale) |
Nothing |
Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment) |
Panasonic Electric Works SUNX DP-101Z |
At 90kPa setting: Approx. 1mL/min ~ Maximum approx. 50L/min |
PISCO ball valve |
Max 0.8MPa |
5℃~50℃ |
Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.) |
LMX2 series Atmospheric pressure/digital pressure gauge type |
![]() |
LMX2-J-P2 |
Available upon quote |
Not compatible (Please use in non-explosion-proof areas.) |
Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.) |
Approx. 1.5kg (1 channel) |
50kPa~150kPa |
Individual (flow rate setting) ~desired number |
Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed |
Our company's needle valve Super Needle (SNPA series equivalent) |
When using a float flowmeter: ±2% (full scale) |
Yes |
Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment) |
Manufactured by Panasonic Electric Works SUNX DP-102Z |
When set to 50kPa: approx. 1mL/min ~ maximum approx. 40L/min |
PISCO ball valve |
Max 0.8MPa |
5℃~50℃ |
Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.) |
LMX2 series Atmospheric pressure/digital pressure gauge type |
![]() |
LMX2-N-P2 |
Available upon quote |
Not compatible (Please use in non-explosion-proof areas.) |
Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.) |
Approx. 1.5kg (1 channel) |
50kPa~150kPa |
Individual (flow rate setting) ~desired number |
Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed |
Our company's needle valve Super Needle (SNPA series equivalent) |
When using a float flowmeter: ±2% (full scale) |
Nothing |
Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment) |
Manufactured by Panasonic Electric Works SUNX DP-102Z |
When set to 50kPa: approx. 1mL/min ~ maximum approx. 40L/min |
PISCO ball valve |
Max 0.8MPa |
5℃~50℃ |
Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.) |
LMX2 series Atmospheric pressure/digital pressure gauge type |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
139.2hrs