All Categories

History

Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-LMX2-J-A2
Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-Front Co., Ltd.

Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)
Front Co., Ltd.

Front Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

139.2hours


About This Product

Various gas mixing equipment for research and development purposes such as welding, food packaging, He leak, CO2 incubator, etc. We respond to the various needs of our customers.

■Super needle technology makes it incredibly easy to use

The gas adjustment/mixing device ``Logmix'' utilizes Front Co., Ltd.'s ``Super Needle'' technology to realize multi-gas and multi-range operation. It can be used for a variety of applications such as bio research, food manufacturing equipment, semiconductor/thin film research, and welding gas.

■Wide valve flow rate adjustment range

Logmix has a built-in "super needle", so it is possible to adjust the gas flow rate over a very wide range with one unit. For example, in the case of nitrogen gas (set pressure 100kPa), the gas flow rate can be easily adjusted over a very wide range of 1mL/min to 30,000mL/min in any range. A flow rate range approximately 30,000 times larger can be adjusted with one unit (one flow path). The variable range of conventional products is about 10 to 20 times the readable range of float type flowmeters. Even with expensive mass flow controllers, the variable range is about 100 times greater. By using LogMix, you can freely mix from ppm level to %.

■Change the gas type and range by replacing the flow meter

Gas flow meters can be easily replaced. Even if the type of gas used or the flow rate (range) of the gas used changes, you can respond by simply replacing the flow meter. The flowmeter has 7 types of gases and 18 types of flow rate ranges, allowing you to choose from over 100 types. Replacement flowmeters can be purchased starting from 1 piece. Even if the flow rate of the gas actually used changes or the type of gas used changes after the installation of the device, this can be done by simply replacing the flow meter, so this can be done at the lowest possible cost. . Unlike general gas equipment, there is no need to replace the entire device.

■Compact and flexible design

It has been designed with a thorough focus on scalability, maintainability, and ease of operation. There is no limit to the number of channels, and any number of channels can be added. You can decide the number of units and connect them as needed. It can be used alone, and additional channels can be added after purchase. The piping fits into the step on the back of the top of the main unit. Wall mounting brackets (optional) allow for easy wall mounting. *Other model numbers are available.

  • Product

    Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)

Share this product


510+ people viewing

Last viewed: 9 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

10 Models of Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Explosion-proof Piping connections Mass Setting pressure gauge Number of mixed components Mixed gas components Flow control needle valve Flow rate accuracy Operation axis rotation speed display Exterior structure Pressure gauge Flow rate setting range for each flow path (N2 gas) Stop valve for each flow path Inlet pressure Operating temperature range Float type flow meter Type
Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-Part Number-LMX2-J-A2

LMX2-J-A2

Available upon quote

Not explosion-proof (It is treated as a safety device for explosion-proof purposes.)
*Excluding types with optional solenoid valve

Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.)

Approx. 1.5kg (1 channel)
* Approximately 2 kg (1 flow path) with solenoid valve

200kPa full scale (recommended set pressure: 50~150kPa)

Individual (flow rate setting) ~desired number
Upper limit for unit (can be easily connected) is 4 channels
For 5 or more channels, use a combination of units with 1 to 4 channels.

Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed

Our company's needle valve Super Needle (SNPA series equivalent)

When using a float flowmeter: ±2% (full scale)
When using flow rate characteristic data: ±5% (setting value)

Yes

Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment)
Optional: Waterproof/dustproof case (Body: ASS resin, Cover: Polycarbonate) Storage

-

Approx. 1mL/min~Maximum approx. 50L/min (at 100kPa setting)

PISCO ball valve

Max 0.8MPa

5℃~50℃

Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.)

LMX2 series atmospheric pressure/analog pressure gauge type

Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-Part Number-LMX2-N-A2

LMX2-N-A2

Available upon quote

Not explosion-proof (It is treated as a safety device for explosion-proof purposes.)
*Excluding types with optional solenoid valve

Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.)

Approx. 1.5kg (1 channel)
* Approximately 2 kg (1 flow path) with solenoid valve

200kPa full scale (recommended set pressure: 50~150kPa)

Individual (flow rate setting) ~desired number
Upper limit for unit (can be easily connected) is 4 channels
For 5 or more channels, use a combination of units with 1 to 4 channels.

Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed

Our company's needle valve Super Needle (SNPA series equivalent)

When using a float flowmeter: ±2% (full scale)
When using flow rate characteristic data: ±5% (setting value)

Nothing

Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment)
Optional: Waterproof/dustproof case (Body: ASS resin, Cover: Polycarbonate) Storage

-

Approx. 1mL/min~Maximum approx. 50L/min (at 100kPa setting)

PISCO ball valve

Max 0.8MPa

5℃~50℃

Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.)

LMX2 series atmospheric pressure/analog pressure gauge type

Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-Part Number-LMX2-J-A4

LMX2-J-A4

Available upon quote

Not explosion-proof (It is treated as a safety device for explosion-proof purposes.)
*Excluding types with optional solenoid valve

Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.)

Approx. 1.5kg (1 channel)
* Approximately 2 kg (1 flow path) with solenoid valve

400kPa full scale (recommended set pressure: 100~300kPa)

Individual (flow rate setting) ~desired number
Upper limit for unit (can be easily connected) is 4 channels
For 5 or more channels, use a combination of units with 1 to 4 channels.

Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed

Our company's needle valve Super Needle (SNPA series equivalent)

When using a float flowmeter: ±2% (full scale)
When using flow rate characteristic data: ±5% (setting value)

Yes

Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment)
Optional: Waterproof/dustproof case (Body: ASS resin, Cover: Polycarbonate) Storage

-

Approx. 1mL/min~Maximum approx. 50L/min (at 100kPa setting)

PISCO ball valve

Max 0.8MPa

5℃~50℃

Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.)

LMX2 series atmospheric pressure/analog pressure gauge type

Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-Part Number-LMX2-N-A4

LMX2-N-A4

Available upon quote

Not explosion-proof (It is treated as a safety device for explosion-proof purposes.)
*Excluding types with optional solenoid valve

Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.)

Approx. 1.5kg (1 channel)
* Approximately 2 kg (1 flow path) with solenoid valve

400kPa full scale (recommended set pressure: 100~300kPa)

Individual (flow rate setting) ~desired number
Upper limit for unit (can be easily connected) is 4 channels
For 5 or more channels, use a combination of units with 1 to 4 channels.

Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed

Our company's needle valve Super Needle (SNPA series equivalent)

When using a float flowmeter: ±2% (full scale)
When using flow rate characteristic data: ±5% (setting value)

Nothing

Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment)
Optional: Waterproof/dustproof case (Body: ASS resin, Cover: Polycarbonate) Storage

-

Approx. 1mL/min~Maximum approx. 50L/min (at 100kPa setting)

PISCO ball valve

Max 0.8MPa

5℃~50℃

Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.)

LMX2 series atmospheric pressure/analog pressure gauge type

Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-Part Number-LMX2-J-A7

LMX2-J-A7

Available upon quote

Not explosion-proof (It is treated as a safety device for explosion-proof purposes.)
*Excluding types with optional solenoid valve

Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.)

Approx. 1.5kg (1 channel)
* Approximately 2 kg (1 flow path) with solenoid valve

700kPa full scale (recommended set pressure: 200~500kPa)
*Maximum set pressure 500kPa

Individual (flow rate setting) ~desired number
Upper limit for unit (can be easily connected) is 4 channels
For 5 or more channels, use a combination of units with 1 to 4 channels.

Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed

Our company's needle valve Super Needle (SNPA series equivalent)

When using a float flowmeter: ±2% (full scale)
When using flow rate characteristic data: ±5% (setting value)

Yes

Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment)
Optional: Waterproof/dustproof case (Body: ASS resin, Cover: Polycarbonate) Storage

-

Approx. 2mL/min~Maximum approx. 50L/min (at 200kPa setting)

PISCO ball valve

Max 0.8MPa

5℃~50℃

Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.)

LMX2 series atmospheric pressure/analog pressure gauge type

Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-Part Number-LMX2-N-A7

LMX2-N-A7

Available upon quote

Not explosion-proof (It is treated as a safety device for explosion-proof purposes.)
*Excluding types with optional solenoid valve

Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.)

Approx. 1.5kg (1 channel)
* Approximately 2 kg (1 flow path) with solenoid valve

700kPa full scale (recommended set pressure: 200~500kPa)
*Maximum set pressure 500kPa

Individual (flow rate setting) ~desired number
Upper limit for unit (can be easily connected) is 4 channels
For 5 or more channels, use a combination of units with 1 to 4 channels.

Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed

Our company's needle valve Super Needle (SNPA series equivalent)

When using a float flowmeter: ±2% (full scale)
When using flow rate characteristic data: ±5% (setting value)

Nothing

Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment)
Optional: Waterproof/dustproof case (Body: ASS resin, Cover: Polycarbonate) Storage

-

Approx. 2mL/min~Maximum approx. 50L/min (at 200kPa setting)

PISCO ball valve

Max 0.8MPa

5℃~50℃

Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.)

LMX2 series atmospheric pressure/analog pressure gauge type

Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-Part Number-LMX2-J-D2

LMX2-J-D2

Available upon quote

Not compatible (Please use in non-explosion-proof areas.)

Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.)

Approx. 1.5kg (1 channel)
* Approximately 2 kg (1 flow path) with solenoid valve

30kPa~99.9kPa (The display limit of the pressure gauge is 99.9kPa.)

Individual (flow rate setting) ~desired number
Upper limit for unit (can be easily connected) is 4 channels
For 5 or more channels, use a combination of units with 1 to 4 channels.

Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed

Our company's needle valve Super Needle (SNPA series equivalent)

When using a float flowmeter: ±2% (full scale)
When using flow rate characteristic data: ±5% (setting value)

Yes

Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment)
Optional: Waterproof/dustproof case (Body: ASS resin, Cover: Polycarbonate) Storage

Panasonic Electric Works SUNX DP-101Z

At 90kPa setting: Approx. 1mL/min ~ Maximum approx. 50L/min
At 30kPa setting: 0.6mL/min~maximum 25L/min

PISCO ball valve

Max 0.8MPa

5℃~50℃

Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.)

LMX2 series Atmospheric pressure/digital pressure gauge type

Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-Part Number-LMX2-N-D2

LMX2-N-D2

Available upon quote

Not compatible (Please use in non-explosion-proof areas.)

Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.)

Approx. 1.5kg (1 channel)
* Approximately 2 kg (1 flow path) with solenoid valve

30kPa~99.9kPa (The display limit of the pressure gauge is 99.9kPa.)

Individual (flow rate setting) ~desired number
Upper limit for unit (can be easily connected) is 4 channels
For 5 or more channels, use a combination of units with 1 to 4 channels.

Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed

Our company's needle valve Super Needle (SNPA series equivalent)

When using a float flowmeter: ±2% (full scale)
When using flow rate characteristic data: ±5% (setting value)

Nothing

Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment)
Optional: Waterproof/dustproof case (Body: ASS resin, Cover: Polycarbonate) Storage

Panasonic Electric Works SUNX DP-101Z

At 90kPa setting: Approx. 1mL/min ~ Maximum approx. 50L/min
At 30kPa setting: 0.6mL/min~maximum 25L/min

PISCO ball valve

Max 0.8MPa

5℃~50℃

Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.)

LMX2 series Atmospheric pressure/digital pressure gauge type

Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-Part Number-LMX2-J-P2

LMX2-J-P2

Available upon quote

Not compatible (Please use in non-explosion-proof areas.)

Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.)

Approx. 1.5kg (1 channel)
* Approximately 2 kg (1 flow path) with solenoid valve

50kPa~150kPa

Individual (flow rate setting) ~desired number
Upper limit for unit (can be easily connected) is 4 channels
For 5 or more channels, use a combination of units with 1 to 4 channels.

Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed

Our company's needle valve Super Needle (SNPA series equivalent)

When using a float flowmeter: ±2% (full scale)
When using flow rate characteristic data: ±5% (setting value)

Yes

Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment)
Optional: Waterproof/dustproof case (Body: ASS resin, Cover: Polycarbonate) Storage

Manufactured by Panasonic Electric Works SUNX DP-102Z

When set to 50kPa: approx. 1mL/min ~ maximum approx. 40L/min
When set to 150kPa: approx. 2mL/min ~ maximum approx. 50L/min

PISCO ball valve

Max 0.8MPa

5℃~50℃

Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.)

LMX2 series Atmospheric pressure/digital pressure gauge type

Multi-gas/multi-range compatible gas flow control device/gas mixing device LogMIX (Log Mix)-Part Number-LMX2-N-P2

LMX2-N-P2

Available upon quote

Not compatible (Please use in non-explosion-proof areas.)

Φ6 one-touch fitting (also available for Rc1/4inch, Rc1/8inch, etc.)

Approx. 1.5kg (1 channel)
* Approximately 2 kg (1 flow path) with solenoid valve

50kPa~150kPa

Individual (flow rate setting) ~desired number
Upper limit for unit (can be easily connected) is 4 channels
For 5 or more channels, use a combination of units with 1 to 4 channels.

Inert gas, non-corrosive gas, non-toxic gas, non-strongly adsorbent gas, and other gases whose safety has been confirmed

Our company's needle valve Super Needle (SNPA series equivalent)

When using a float flowmeter: ±2% (full scale)
When using flow rate characteristic data: ±5% (setting value)

Nothing

Basic: For indoor use (corrosion-resistant aluminum alloy alumite treatment)
Optional: Waterproof/dustproof case (Body: ASS resin, Cover: Polycarbonate) Storage

Manufactured by Panasonic Electric Works SUNX DP-102Z

When set to 50kPa: approx. 1mL/min ~ maximum approx. 40L/min
When set to 150kPa: approx. 2mL/min ~ maximum approx. 50L/min

PISCO ball valve

Max 0.8MPa

5℃~50℃

Choose from 7 types of gas and 17 to 18 types of ranges (The flow meter is structured so that it can be easily replaced, and you can purchase from 1 flow meter.)

LMX2 series Atmospheric pressure/digital pressure gauge type

Click on the part number for more information about each product

Other products of Front Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Front Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

139.2hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree