Non-invasive cholesterol/glucose measuring device CLE-110-CLE-110
Non-invasive cholesterol/glucose measuring device CLE-110-Photoscience Co., Ltd.

Non-invasive cholesterol/glucose measuring device CLE-110
Photoscience Co., Ltd.

Photoscience Co., Ltd.'s Response Status

Response Rate

100.0%

Response Time

2.2hours

Very Fast Response


About This Product

■Summary

This system non-invasively measures cholesterol ester and glucose concentrations in human skin, and measures total cholesterol, LDL, and blood sugar levels in the blood.

■System configuration

This system consists of the following devices. 1) Infrared light source section 2) Measuring part (ATR sensor part) 3) Irradiation optical system 4) Measurement optical system 5) Rotating filter unit 6) Detection part 7) Measurement control and data processing software 8) PC for control and data processing

■Specifications and functions of each part

1. Infrared light source The light source is a small infrared light source that efficiently emits light in the infrared region and has a small overall heat capacity to prevent overheating of the sensor unit. 2. Measuring part (ATR sensor part) ATR prism is an element that measures the absorbance of a sample by generating near-field light on its surface. 3. Irradiation optical system We will build an optical system that collects infrared light from a light source and irradiates it to the ATR prism. Brightness: F=1.0 Spherical mirror M1 converges the source light onto the ATR prism. 4. Measurement optical system This optical system efficiently collects the light emitted from the ATR prism, passes it through a filter, and then focuses it on the sensor. 5. Rotating filter unit This is a mechanism that sequentially inserts filters that separate the ATR output light (measurement light) into the light beam. 6. Detector Since the measurement wavelength spans a wide range in the infrared region (approximately 2 μm to 9 μm), - is limited. Among these, we adopted the following pyroelectric infrared sensor unit due to its good sensitivity and time response. 7. Chopper Pyroelectric sensors need to be used with intermittent light (alternating current), so a chopper is used. Since fluctuations in the chopping frequency affect the stability of the data, it is necessary that the rotation speed be precisely and precisely controlled. 8. Film sample holder In order to check the accuracy and concentration linearity of the measured values, it is necessary to measure a standard sample with a known absorption spectrum. Therefore, a mechanism is provided to set a film-like standard sample in the optical path.

  • Product

    Non-invasive cholesterol/glucose measuring device CLE-110

Share this product


210+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Non-invasive cholesterol/glucose measuring device CLE-110

Image Part Number Price (excluding tax) Electrical system separate case Equipment height Width Depth ATR Prism Long ATR prism
Non-invasive cholesterol/glucose measuring device CLE-110-Part Number-CLE-110

CLE-110

Available upon quote

Approximately 5,300cm3

260mm

350mm

250mm

10×44×t2

10 (or5) ×24×t2

Other products of Photoscience Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Photoscience Co., Ltd.

About Company Handling This Product

Response Rate

100.0%


Response Time

2.2hrs

  • Japan

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree