OIL COOLING UNIT Oil con series (oil cooling circulation type)Handling Company
Nippon Mekuman Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Evaporator | Temperature control fixed type range (℃) | Temperature control Fixed type Controlled object | Temperature control synchronized type standard | Temperature control Tuning type Tuning range (K) | Temperature control Synchronized type Controlled object | Maximum power consumption/maximum current consumption (when cooling) | Exterior color | External dimensions H×W×D (mm) | Compressor (totally hermetic DC swing type) | Circuit voltage (operating circuit) | Condenser | Refrigerant control | Refrigerant charge amount (kg) | Refrigerant CO2 equivalent amount (tCO2eq) | Cooling capacity 50/60Hz (kW) | Protection device | Protection function | Supply power circuit voltage (main circuit) | Usage range Product external pressure loss | Usage range Oil viscosity (mm2/s) | Usage range Room temperature (℃) | Usage range Inlet oil temperature (℃) | Propeller fan (electric motor) | Type | Oil pump electric motor | Oil pump opening pressure (MPa) | Oil pump discharge amount (L/min) | Oil conditioner equivalent horsepower (HP) | Maximum power consumption/maximum current consumption (when heating) | Heater (kW) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AKZ14A-500 |
Available upon quote |
Cross fin coil type |
5~50 |
Inlet oil temperature or outlet oil temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) |
・380V 50/60Hz: 1.01kW/2.3A |
Ivory white |
650×360×440 |
Equivalent to 0.4kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.54 |
1.13 |
1.3/1.4 |
Overcurrent relay (for pump motor) - Reverse phase protection device - Low room temperature protection thermostat - High oil temperature protection thermostat - Low oil temperature protection thermostat - Discharge pipe temperature thermostat - Condenser temperature thermostat - Inverter protection device set - Compressor protection thermostat |
Restart prevention timer/refrigerant leak detection |
3 phase AC380/400/415V 50/60Hz |
・Discharge side: 0.5MPa or less |
1.4~200 (ISO VG2~32) |
5~45 |
5~50 |
Φ240,54W |
- |
0.4kW-4P |
0.5 |
12/14.4 |
0.5 |
- | - | |
AKZ14A-500-B |
Available upon quote |
Cross fin coil type |
5~50 |
Inlet oil temperature or outlet oil temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) |
・380V 50/60Hz: 1.01kW/2.3A |
Ivory white |
650×360×440 |
Equivalent to 0.4kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.54 |
1.13 |
1.3/1.4 |
Equipped with standard equipment + hardwired circuit breaker |
Restart prevention timer/refrigerant leak detection |
3 phase AC380/400/415V 50/60Hz |
・Discharge side: 0.5MPa or less |
1.4~200 (ISO VG2~32) |
5~45 |
5~50 |
Φ240,54W |
With breaker |
0.4kW-4P |
0.5 |
12/14.4 |
0.5 |
- | - | |
AKZ14A-500-C |
Available upon quote |
Cross fin coil type |
5~50 |
Inlet oil temperature or outlet oil temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) |
・380V 50/60Hz: 1.01kW/2.3A |
Ivory white |
650×360×440 |
Equivalent to 0.4kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.54 |
1.13 |
1.3/1.4 |
Equipped with standard equipment + high pressure switch |
Restart prevention timer/refrigerant leak detection |
3 phase AC380/400/415V 50/60Hz |
・Discharge side: 0.5MPa or less |
1.4~200 (ISO VG2~32) |
5~45 |
5~50 |
Φ240,54W |
CE compatible |
0.4kW-4P |
0.5 |
12/14.4 |
0.5 |
- | - | |
AKZ14A-500-H |
Available upon quote |
Cross fin coil type |
5~50 |
Inlet oil temperature or outlet oil temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) |
・380V 50/60Hz: 1.01kW/2.3A |
Ivory white |
950×360×440 |
Equivalent to 0.4kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.54 |
1.13 |
1.3/1.4 |
Equipped with standard equipment + overheating prevention thermostat and dry firing prevention switch |
Restart prevention timer/refrigerant leak detection |
3 phase AC380/400/415V 50/60Hz |
・Discharge side: 0.5MPa or less |
1.4~200 (ISO VG2~32) |
5~45 |
5~50 |
Φ240,54W |
With heater |
0.4kW-4P |
0.5 |
12/14.4 |
0.5 |
・380V 50/60Hz: 1.70kW/2.7A |
1 |
|
AKZ14A-500-T |
Available upon quote |
Cross fin coil type |
5~50 |
Inlet oil temperature or outlet oil temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) |
・380V 50/60Hz: 1.01kW/2.3A |
Ivory white |
810×360×535 |
Equivalent to 0.4kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.54 |
1.13 |
1.3/1.4 |
Overcurrent relay (for pump motor) - Reverse phase protection device - Low room temperature protection thermostat - High oil temperature protection thermostat - Low oil temperature protection thermostat - Discharge pipe temperature thermostat - Condenser temperature thermostat - Inverter protection device set |
Restart prevention timer/refrigerant leak detection |
3 phase AC380/400/415V 50/60Hz |
・Discharge side: 0.5MPa or less |
1.4~200 (ISO VG2~32) |
5~45 |
5~50 |
Φ240,54W |
With tank |
0.4kW-4P |
0.5 |
12/14.4 |
0.5 |
- | - | |
AKZ32A-500 |
Available upon quote |
Cross fin coil type |
5~50 |
Inlet oil temperature or outlet oil temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) |
・380V 50/60Hz: 1.59kW/3.1A |
Ivory white |
775×360×440 |
Equivalent to 0.75kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.81 |
1.7 |
2.8/3.2 |
Overcurrent relay (for pump motor) - Reverse phase protection device - Low room temperature protection thermostat - High oil temperature protection thermostat - Low oil temperature protection thermostat - Discharge pipe temperature thermostat - Condenser temperature thermostat - Inverter protection device set |
Restart prevention timer/refrigerant leak detection |
3 phase AC380/400/415V 50/60Hz |
・Discharge side: 0.5MPa or less |
1.4~200 (ISO VG2~32) |
5~45 |
5~50 |
Φ300,54W |
- |
0.4kW-4P |
0.6 |
24/28.8 |
1.2 |
- | - | |
AKZ32A-500-B |
Available upon quote |
Cross fin coil type |
5~50 |
Inlet oil temperature or outlet oil temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) |
・380V 50/60Hz: 1.59kW/3.1A |
Ivory white |
775×360×440 |
Equivalent to 0.75kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.81 |
1.7 |
2.8/3.2 |
Equipped with standard equipment + hardwired circuit breaker |
Restart prevention timer/refrigerant leak detection |
3 phase AC380/400/415V 50/60Hz |
・Discharge side: 0.5MPa or less |
1.4~200 (ISO VG2~32) |
5~45 |
5~50 |
Φ300,54W |
With breaker |
0.4kW-4P |
0.6 |
24/28.8 |
1.2 |
- | - | |
AKZ32A-500-C |
Available upon quote |
Cross fin coil type |
5~50 |
Inlet oil temperature or outlet oil temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) |
・380V 50/60Hz: 1.59kW/3.1A |
Ivory white |
775×360×440 |
Equivalent to 0.75kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.81 |
1.7 |
2.8/3.2 |
Equipped with standard equipment + high pressure switch |
Restart prevention timer/refrigerant leak detection |
3 phase AC380/400/415V 50/60Hz |
・Discharge side: 0.5MPa or less |
1.4~200 (ISO VG2~32) |
5~45 |
5~50 |
Φ300,54W |
CE compatible |
0.4kW-4P |
0.6 |
24/28.8 |
1.2 |
- | - | |
AKZ32A-500-H |
Available upon quote |
Cross fin coil type |
5~50 |
Inlet oil temperature or outlet oil temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) |
・380V 50/60Hz: 1.59kW/3.1A |
Ivory white |
1,075×360×440 |
Equivalent to 0.75kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.81 |
1.7 |
2.8/3.2 |
Equipped with standard equipment + overheating prevention thermostat and dry firing prevention switch |
Restart prevention timer/refrigerant leak detection |
3 phase AC380/400/415V 50/60Hz |
・Discharge side: 0.5MPa or less |
1.4~200 (ISO VG2~32) |
5~45 |
5~50 |
Φ300,54W |
With heater |
0.4kW-4P |
0.6 |
24/28.8 |
1.2 |
・380V 50/60Hz: 1.75kW/2.8A |
1 |
|
AKZ32A-500-T |
Available upon quote |
Cross fin coil type |
5~50 |
Inlet oil temperature or outlet oil temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) |
・380V 50/60Hz: 1.59kW/3.1A |
Ivory white |
965×360×535 |
Equivalent to 0.75kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.81 |
1.7 |
2.8/3.2 |
Overcurrent relay (for pump motor) - Reverse phase protection device - Low room temperature protection thermostat - High oil temperature protection thermostat - Low oil temperature protection thermostat - Discharge pipe temperature thermostat - Condenser temperature thermostat - Inverter protection device set |
Restart prevention timer/refrigerant leak detection |
3 phase AC380/400/415V 50/60Hz |
・Discharge side: 0.5MPa or less |
1.4~200 (ISO VG2~32) |
5~45 |
5~50 |
Φ300,54W |
With tank |
0.4kW-4P |
0.6 |
24/28.8 |
1.2 |
- | - |
Click on the part number for more information about each product