Product
OIL COOLING UNIT Oil con series (oil cooling circulation type)Handling Company
Nippon Mekuman Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Circuit voltage (operating circuit) | Compressor (totally hermetic DC swing type) | Condenser | Cooling capacity 50/60Hz (kW) | Evaporator | Exterior color | External dimensions H×W×D (mm) | Heater (kW) | Maximum power consumption/maximum current consumption (when cooling) | Maximum power consumption/maximum current consumption (when heating) | Oil conditioner equivalent horsepower (HP) | Oil pump discharge amount (L/min) | Oil pump electric motor | Oil pump opening pressure (MPa) | Propeller fan (electric motor) | Protection device | Protection function | Refrigerant CO2 equivalent amount (tCO2eq) | Refrigerant charge amount (kg) | Refrigerant control | Supply power circuit voltage (main circuit) | Temperature control Fixed type Controlled object | Temperature control Synchronized type Controlled object | Temperature control Tuning type Tuning range (K) | Temperature control fixed type range (℃) | Temperature control synchronized type standard | Type | Usage range Inlet oil temperature (℃) | Usage range Oil viscosity (mm2/s) | Usage range Product external pressure loss | Usage range Room temperature (℃) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AKZ14A-500 |
Available upon quote | DC12/24V | Equivalent to 0.4kW | Cross fin coil type | 1.3/1.4 | Cross fin coil type | Ivory white | 650×360×440 | - |
・380V 50/60Hz: 1.01kW/2.3A ・400V 50/60Hz: 1.02kW/2.2A ・415V 50/60Hz: 1.03kW/2.2A |
- | 0.5 | 12/14.4 | 0.4kW-4P | 0.5 | Φ240,54W | Overcurrent relay (for pump motor) - Reverse phase protection device - Low room temperature protection thermostat - High oil temperature protection thermostat - Low oil temperature protection thermostat - Discharge pipe temperature thermostat - Condenser temperature thermostat - Inverter protection device set - Compressor protection thermostat | Restart prevention timer/refrigerant leak detection | 1.13 | 0.54 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC380/400/415V 50/60Hz | Inlet oil temperature or outlet oil temperature | Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | - | 5~50 | 1.4~200 (ISO VG2~32) |
・Discharge side: 0.5MPa or less ・Suction side: within -30.7kPa |
5~45 | |
AKZ14A-500-B |
Available upon quote | DC12/24V | Equivalent to 0.4kW | Cross fin coil type | 1.3/1.4 | Cross fin coil type | Ivory white | 650×360×440 | - |
・380V 50/60Hz: 1.01kW/2.3A ・400V 50/60Hz: 1.02kW/2.2A ・415V 50/60Hz: 1.03kW/2.2A |
- | 0.5 | 12/14.4 | 0.4kW-4P | 0.5 | Φ240,54W | Equipped with standard equipment + hardwired circuit breaker | Restart prevention timer/refrigerant leak detection | 1.13 | 0.54 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC380/400/415V 50/60Hz | Inlet oil temperature or outlet oil temperature | Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | With breaker | 5~50 | 1.4~200 (ISO VG2~32) |
・Discharge side: 0.5MPa or less ・Suction side: within -30.7kPa |
5~45 | |
AKZ14A-500-C |
Available upon quote | DC12/24V | Equivalent to 0.4kW | Cross fin coil type | 1.3/1.4 | Cross fin coil type | Ivory white | 650×360×440 | - |
・380V 50/60Hz: 1.01kW/2.3A ・400V 50/60Hz: 1.02kW/2.2A ・415V 50/60Hz: 1.03kW/2.2A |
- | 0.5 | 12/14.4 | 0.4kW-4P | 0.5 | Φ240,54W | Equipped with standard equipment + high pressure switch | Restart prevention timer/refrigerant leak detection | 1.13 | 0.54 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC380/400/415V 50/60Hz | Inlet oil temperature or outlet oil temperature | Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | CE compatible | 5~50 | 1.4~200 (ISO VG2~32) |
・Discharge side: 0.5MPa or less ・Suction side: within -30.7kPa |
5~45 | |
AKZ14A-500-H |
Available upon quote | DC12/24V | Equivalent to 0.4kW | Cross fin coil type | 1.3/1.4 | Cross fin coil type | Ivory white | 950×360×440 | 1 |
・380V 50/60Hz: 1.01kW/2.3A ・400V 50/60Hz: 1.02kW/2.2A ・415V 50/60Hz: 1.03kW/2.2A |
・380V 50/60Hz: 1.70kW/2.7A ・400V 50/60Hz: 1.80kW/2.7A ・415V 50/60Hz: 1.91kW/2.8A |
0.5 | 12/14.4 | 0.4kW-4P | 0.5 | Φ240,54W | Equipped with standard equipment + overheating prevention thermostat and dry firing prevention switch | Restart prevention timer/refrigerant leak detection | 1.13 | 0.54 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC380/400/415V 50/60Hz | Inlet oil temperature or outlet oil temperature | Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | With heater | 5~50 | 1.4~200 (ISO VG2~32) |
・Discharge side: 0.5MPa or less ・Suction side: within -30.7kPa |
5~45 | |
AKZ14A-500-T |
Available upon quote | DC12/24V | Equivalent to 0.4kW | Cross fin coil type | 1.3/1.4 | Cross fin coil type | Ivory white | 810×360×535 | - |
・380V 50/60Hz: 1.01kW/2.3A ・400V 50/60Hz: 1.02kW/2.2A ・415V 50/60Hz: 1.03kW/2.2A |
- | 0.5 | 12/14.4 | 0.4kW-4P | 0.5 | Φ240,54W | Overcurrent relay (for pump motor) - Reverse phase protection device - Low room temperature protection thermostat - High oil temperature protection thermostat - Low oil temperature protection thermostat - Discharge pipe temperature thermostat - Condenser temperature thermostat - Inverter protection device set | Restart prevention timer/refrigerant leak detection | 1.13 | 0.54 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC380/400/415V 50/60Hz | Inlet oil temperature or outlet oil temperature | Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | With tank | 5~50 | 1.4~200 (ISO VG2~32) |
・Discharge side: 0.5MPa or less ・Suction side: within -30.7kPa |
5~45 | |
AKZ32A-500 |
Available upon quote | DC12/24V | Equivalent to 0.75kW | Cross fin coil type | 2.8/3.2 | Cross fin coil type | Ivory white | 775×360×440 | - |
・380V 50/60Hz: 1.59kW/3.1A ・400V 50/60Hz: 1.60kW/3.0A ・415V 50/60Hz: 1.60kW/2.9A |
- | 1.2 | 24/28.8 | 0.4kW-4P | 0.6 | Φ300,54W | Overcurrent relay (for pump motor) - Reverse phase protection device - Low room temperature protection thermostat - High oil temperature protection thermostat - Low oil temperature protection thermostat - Discharge pipe temperature thermostat - Condenser temperature thermostat - Inverter protection device set | Restart prevention timer/refrigerant leak detection | 1.7 | 0.81 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC380/400/415V 50/60Hz | Inlet oil temperature or outlet oil temperature | Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | - | 5~50 | 1.4~200 (ISO VG2~32) |
・Discharge side: 0.5MPa or less ・Suction side: within -30.7kPa |
5~45 | |
AKZ32A-500-B |
Available upon quote | DC12/24V | Equivalent to 0.75kW | Cross fin coil type | 2.8/3.2 | Cross fin coil type | Ivory white | 775×360×440 | - |
・380V 50/60Hz: 1.59kW/3.1A ・400V 50/60Hz: 1.60kW/3.0A ・415V 50/60Hz: 1.60kW/2.9A |
- | 1.2 | 24/28.8 | 0.4kW-4P | 0.6 | Φ300,54W | Equipped with standard equipment + hardwired circuit breaker | Restart prevention timer/refrigerant leak detection | 1.7 | 0.81 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC380/400/415V 50/60Hz | Inlet oil temperature or outlet oil temperature | Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | With breaker | 5~50 | 1.4~200 (ISO VG2~32) |
・Discharge side: 0.5MPa or less ・Suction side: within -30.7kPa |
5~45 | |
AKZ32A-500-C |
Available upon quote | DC12/24V | Equivalent to 0.75kW | Cross fin coil type | 2.8/3.2 | Cross fin coil type | Ivory white | 775×360×440 | - |
・380V 50/60Hz: 1.59kW/3.1A ・400V 50/60Hz: 1.60kW/3.0A ・415V 50/60Hz: 1.60kW/2.9A |
- | 1.2 | 24/28.8 | 0.4kW-4P | 0.6 | Φ300,54W | Equipped with standard equipment + high pressure switch | Restart prevention timer/refrigerant leak detection | 1.7 | 0.81 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC380/400/415V 50/60Hz | Inlet oil temperature or outlet oil temperature | Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | CE compatible | 5~50 | 1.4~200 (ISO VG2~32) |
・Discharge side: 0.5MPa or less ・Suction side: within -30.7kPa |
5~45 | |
AKZ32A-500-H |
Available upon quote | DC12/24V | Equivalent to 0.75kW | Cross fin coil type | 2.8/3.2 | Cross fin coil type | Ivory white | 1,075×360×440 | 1 |
・380V 50/60Hz: 1.59kW/3.1A ・400V 50/60Hz: 1.60kW/3.0A ・415V 50/60Hz: 1.60kW/2.9A |
・380V 50/60Hz: 1.75kW/2.8A ・400V 50/60Hz: 1.85kW/2.8A ・415V 50/60Hz: 1.96kW/2.9A |
1.2 | 24/28.8 | 0.4kW-4P | 0.6 | Φ300,54W | Equipped with standard equipment + overheating prevention thermostat and dry firing prevention switch | Restart prevention timer/refrigerant leak detection | 1.7 | 0.81 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC380/400/415V 50/60Hz | Inlet oil temperature or outlet oil temperature | Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | With heater | 5~50 | 1.4~200 (ISO VG2~32) |
・Discharge side: 0.5MPa or less ・Suction side: within -30.7kPa |
5~45 | |
AKZ32A-500-T |
Available upon quote | DC12/24V | Equivalent to 0.75kW | Cross fin coil type | 2.8/3.2 | Cross fin coil type | Ivory white | 965×360×535 | - |
・380V 50/60Hz: 1.59kW/3.1A ・400V 50/60Hz: 1.60kW/3.0A ・415V 50/60Hz: 1.60kW/2.9A |
- | 1.2 | 24/28.8 | 0.4kW-4P | 0.6 | Φ300,54W | Overcurrent relay (for pump motor) - Reverse phase protection device - Low room temperature protection thermostat - High oil temperature protection thermostat - Low oil temperature protection thermostat - Discharge pipe temperature thermostat - Condenser temperature thermostat - Inverter protection device set | Restart prevention timer/refrigerant leak detection | 1.7 | 0.81 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC380/400/415V 50/60Hz | Inlet oil temperature or outlet oil temperature | Inlet oil temperature or outlet oil temperature (Factory setting is inlet oil temperature) | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | With tank | 5~50 | 1.4~200 (ISO VG2~32) |
・Discharge side: 0.5MPa or less ・Suction side: within -30.7kPa |
5~45 |