All Categories
History
Product
OIL COOLING UNIT Oil conditioner AKC 9 series (circulation type)Handling Company
Nippon Mekuman Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Evaporator | Temperature control fixed type range (℃) | Temperature control Fixed type Controlled object | Temperature control synchronized type standard | Temperature control Tuning type Tuning range (K) | Temperature control Synchronized type Controlled object | Maximum power consumption/maximum current consumption | Connection piping Liquid inlet/liquid outlet | Exterior color | External dimensions H×W×D (mm) | Compressor (totally hermetic DC swing type) | Circuit voltage (operating circuit) | Condenser | Refrigerant control | Refrigerant charge amount (kg) | Cooling capacity 50/60Hz (kW) | Protection device | Protection function | Supply power circuit voltage (main circuit) | Usage range Withstand pressure (MPa) | Usage range Oil viscosity (mm2/s) | Usage range Circulation amount (L/min) | Usage range Room temperature (℃) | Usage range Rated circulation rate (L/min) | Usage range Inlet liquid temperature (℃) | Usable liquid | Pump | Propeller fan (electric motor) | Type | Oil conditioner equivalent horsepower (HP) | Heater (kW) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AKC359 |
Available upon quote |
Shell end coil type |
5~50 |
Inlet liquid temperature or outlet liquid temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet liquid temperature or outlet liquid temperature (Factory setting is inlet liquid temperature) |
・200V 50Hz: 1.17kW/4.2A |
Rc3/4 |
Ivory white |
995×450×560 |
Equivalent to 0.75kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.8 |
3.5/3.5 |
Overcurrent relay (for pump motor) - Discharge pipe temperature thermostat - Condenser temperature thermostat - Reverse phase protection device - Low room temperature protection thermostat - High liquid temperature protection thermostat - Low liquid temperature protection thermostat - Inverter protection device set - Circuit breaker |
Restart prevention timer, refrigerant leak detection, evaporator clogging detection (suction pipe temperature thermostat) |
3 phase AC200/200/220V 50/60Hz |
0.2 |
~200 (water soluble ~ISO VG32) |
15 or more |
5~45 |
35 |
5~50 |
Lubricating oil, hydraulic fluid, cutting oil, water-soluble coolant fluid, grinding fluid (please use clean fluid that can pass through a 40 mesh or higher filtration device) |
- |
Φ300,54W |
- |
1.2 |
- | |
AKC359-C |
Available upon quote |
Shell end coil type |
5~50 |
Inlet liquid temperature or outlet liquid temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet liquid temperature or outlet liquid temperature (Factory setting is inlet liquid temperature) |
・200V 50Hz: 1.17kW/4.2A |
Rc3/4 |
Ivory white |
995×450×560 |
Equivalent to 0.75kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.8 |
3.5/3.5 |
Equipped with standard equipment + high pressure switch/compressor protection thermostat |
Restart prevention timer, refrigerant leak detection, evaporator clogging detection (suction pipe temperature thermostat) |
3 phase AC200/200/220V 50/60Hz |
0.2 |
~200 (water soluble ~ISO VG32) |
15 or more |
5~45 |
35 |
5~50 |
Lubricating oil, hydraulic fluid, cutting oil, water-soluble coolant fluid, grinding fluid (please use clean fluid that can pass through a 40 mesh or higher filtration device) |
- |
Φ300,54W |
CE compatible |
1.2 |
- | |
AKC359-H |
Available upon quote |
Shell end coil type |
5~50 |
Inlet liquid temperature or outlet liquid temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet liquid temperature or outlet liquid temperature (Factory setting is inlet liquid temperature) |
・200V 50Hz: 1.17kW/4.2A |
Rc3/4 |
Ivory white |
995×450×560 |
Equivalent to 0.75kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.8 |
3.5/3.5 |
Equipped with standard equipment + thermal fuse/overheat prevention temperature switch |
Restart prevention timer, refrigerant leak detection, evaporator clogging detection (suction pipe temperature thermostat) |
3 phase AC200/200/220V 50/60Hz |
0.2 |
~200 (water soluble ~ISO VG32) |
15 or more |
5~45 |
35 |
5~50 |
Lubricating oil, hydraulic fluid, cutting oil, water-soluble coolant fluid, grinding fluid (please use clean fluid that can pass through a 40 mesh or higher filtration device) |
- |
Φ300,54W |
With heater |
1.2 |
1 |
|
AKC359-200 |
Available upon quote |
Shell end coil type |
5~50 |
Inlet liquid temperature or outlet liquid temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet liquid temperature or outlet liquid temperature (Factory setting is inlet liquid temperature) |
・200V 50Hz: 1.44kW/5.3A |
Rc3/4 |
Ivory white |
995×450×560 |
Equivalent to 0.75kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
0.8 |
3.2/3.2 |
Overcurrent relay (for pump motor) - Discharge pipe temperature thermostat - Condenser temperature thermostat - Reverse phase protection device - Low room temperature protection thermostat - High liquid temperature protection thermostat - Low liquid temperature protection thermostat - Inverter protection device set - Circuit breaker |
Restart prevention timer, refrigerant leak detection, evaporator clogging detection (suction pipe temperature thermostat) |
3 phase AC200/200/220V 50/60Hz |
0.2 |
~200 (water soluble ~ISO VG32) |
15 or more |
5~45 |
35 |
5~50 |
Lubricating oil, hydraulic fluid, cutting oil, water-soluble coolant fluid, grinding fluid (please use clean fluid that can pass through a 40 mesh or higher filtration device) |
・Electric motor: 0.4kW-2P |
Φ300,54W |
With pump |
1.2 |
- | |
AKC569 |
Available upon quote |
Shell end coil type |
5~50 |
Inlet liquid temperature or outlet liquid temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet liquid temperature or outlet liquid temperature (Factory setting is inlet liquid temperature) |
・200V 50Hz: 1.78kW/6.2A |
Rc3/4 |
Ivory white |
1,200×470×670 |
Equivalent to 1.5kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
1.25 |
5.6/5.6 |
Overcurrent relay (for pump motor) - Discharge pipe temperature thermostat - Condenser temperature thermostat - Reverse phase protection device - Low room temperature protection thermostat - High liquid temperature protection thermostat - Low liquid temperature protection thermostat - Inverter protection device set - Circuit breaker |
Restart prevention timer, refrigerant leak detection, evaporator clogging detection (suction pipe temperature thermostat) |
3 phase AC200/200/220V 50/60Hz |
0.2 |
~200 (water soluble ~ISO VG32) |
15 or more |
5~45 |
35 |
5~50 |
Lubricating oil, hydraulic fluid, cutting oil, water-soluble coolant fluid, grinding fluid (please use clean fluid that can pass through a 40 mesh or higher filtration device) |
- |
Φ400,100W |
- |
2 |
- | |
AKC569-C |
Available upon quote |
Shell end coil type |
5~50 |
Inlet liquid temperature or outlet liquid temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet liquid temperature or outlet liquid temperature (Factory setting is inlet liquid temperature) |
・200V 50Hz: 1.78kW/6.2A |
Rc3/4 |
Ivory white |
1,200×470×670 |
Equivalent to 1.5kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
1.25 |
5.6/5.6 |
Equipped with standard equipment + high pressure switch/compressor protection thermostat |
Restart prevention timer, refrigerant leak detection, evaporator clogging detection (suction pipe temperature thermostat) |
3 phase AC200/200/220V 50/60Hz |
0.2 |
~200 (water soluble ~ISO VG32) |
15 or more |
5~45 |
35 |
5~50 |
Lubricating oil, hydraulic fluid, cutting oil, water-soluble coolant fluid, grinding fluid (please use clean fluid that can pass through a 40 mesh or higher filtration device) |
- |
Φ400,100W |
CE compatible |
2 |
- | |
AKC569-H |
Available upon quote |
Shell end coil type |
5~50 |
Inlet liquid temperature or outlet liquid temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet liquid temperature or outlet liquid temperature (Factory setting is inlet liquid temperature) |
・200V 50Hz: 2.34kW/7.0A |
Rc3/4 |
Ivory white |
1,200×470×670 |
Equivalent to 1.5kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
1.25 |
5.6/5.6 |
Equipped with standard equipment + thermal fuse/overheat prevention temperature switch |
Restart prevention timer, refrigerant leak detection, evaporator clogging detection (suction pipe temperature thermostat) |
3 phase AC200/200/220V 50/60Hz |
0.2 |
~200 (water soluble ~ISO VG32) |
15 or more |
5~45 |
35 |
5~50 |
Lubricating oil, hydraulic fluid, cutting oil, water-soluble coolant fluid, grinding fluid (please use clean fluid that can pass through a 40 mesh or higher filtration device) |
- |
Φ400,100W |
With heater |
2 |
2 |
|
AKC569-200 |
Available upon quote |
Shell end coil type |
5~50 |
Inlet liquid temperature or outlet liquid temperature |
Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) |
-9.9~+9.9 relative to standard temperature (0.0 at factory shipment) |
Inlet liquid temperature or outlet liquid temperature (Factory setting is inlet liquid temperature) |
・200V 50Hz: 2.10kW/7.4A |
Rc3/4 |
Ivory white |
1,200×470×670 |
Equivalent to 1.5kW |
DC12/24V |
Cross fin coil type |
Compressor rotation speed + electronic expansion valve opening by inverter |
1.25 |
5.3/5.3 |
Overcurrent relay (for pump motor) - Discharge pipe temperature thermostat - Condenser temperature thermostat - Reverse phase protection device - Low room temperature protection thermostat - High liquid temperature protection thermostat - Low liquid temperature protection thermostat - Inverter protection device set - Circuit breaker |
Restart prevention timer, refrigerant leak detection, evaporator clogging detection (suction pipe temperature thermostat) |
3 phase AC200/200/220V 50/60Hz |
0.2 |
~200 (water soluble ~ISO VG32) |
15 or more |
5~45 |
35 |
5~50 |
Lubricating oil, hydraulic fluid, cutting oil, water-soluble coolant fluid, grinding fluid (please use clean fluid that can pass through a 40 mesh or higher filtration device) |
・Electric motor: 0.4kW-2P |
Φ400,100W |
With pump |
2 |
- |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.