Product
OIL COOLING UNIT Oil conditioner AKJ 9 series (immersion type)Handling Company
Nippon Mekuman Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Capacity control range | Circuit voltage (operating circuit) | Compressor (totally hermetic DC swing type) | Condenser | Cooling capacity 50/60Hz (kW) | Evaporator | Exterior color | External dimensions H×W×D (mm) | Heater (kW) | Maximum power consumption/maximum current consumption (when cooling) | Maximum power consumption/maximum current consumption (when heating) | Oil conditioner equivalent horsepower (HP) | Oil temperature controller resolution | Propeller fan (electric motor) | Protection device | Protection function | Refrigerant charge amount (kg) | Refrigerant control | Stirrer (electric motor) | Supply power circuit voltage (main circuit) | Temperature control Fixed type Controlled object | Temperature control Synchronized type Controlled object | Temperature control Tuning type Tuning range (K) | Temperature control fixed type range (℃) | Temperature control synchronized type standard | Timer function | Transformer capacity | Type | Usage range Oil viscosity (mm2/s) | Usage range Room temperature (℃) | Usage range Tank liquid temperature (℃) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AKJ189 |
Available upon quote | 0~100% | DC12/24V | Equivalent to 0.4kW | Cross fin coil type | 1.6/1.8 | Open coil type | Ivory white | 920×360×440 | - |
・200V 50Hz: 0.82kW/3.3A ・200V 60Hz: 0.83kW/3.2A ・220V 60Hz: 0.83kW/3.0A |
- | 0.5 | ±0.1℃ | Φ250mm, 54W | Stirrer inner thermostat, discharge pipe temperature thermostat, condenser temperature thermostat, reverse phase protection device, low room temperature protection thermostat, high liquid temperature protection thermostat, low liquid temperature protection thermostat, inverter protection device set | Restart prevention timer/refrigerant leak detection | 0.55 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC, 60W, 4P | 3 phase AC200/200/220V 50/60Hz | Tank liquid temperature | Tank liquid temperature | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | ON timer: 1~999 hours (set in 1 hour increments) | - | - | 0.5~200 | 5~45 | 5~50 | |
AKJ189-B |
Available upon quote | 0~100% | DC12/24V | Equivalent to 0.4kW | Cross fin coil type | 1.6/1.8 | Open coil type | Ivory white | 920×360×440 | - |
・200V 50Hz: 0.82kW/3.3A ・200V 60Hz: 0.83kW/3.2A ・220V 60Hz: 0.83kW/3.0A |
- | 0.5 | ±0.1℃ | Φ250mm, 54W | Stirrer inner thermostat, discharge pipe temperature thermostat, condenser temperature thermostat, reverse phase protection device, low room temperature protection thermostat, high liquid temperature protection thermostat, low liquid temperature protection thermostat, inverter protection device set, circuit breaker | Restart prevention timer/refrigerant leak detection | 0.55 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC, 60W, 4P | 3 phase AC200/200/220V 50/60Hz | Tank liquid temperature | Tank liquid temperature | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | ON timer: 1~999 hours (set in 1 hour increments) | - | With breaker | 0.5~200 | 5~45 | 5~50 | |
AKJ189-C |
Available upon quote | 0~100% | DC12/24V | Equivalent to 0.4kW | Cross fin coil type | 1.6/1.8 | Open coil type | Ivory white | 920×360×440 | - |
・200V 50Hz: 0.82kW/3.3A ・200V 60Hz: 0.83kW/3.2A ・220V 60Hz: 0.83kW/3.0A |
- | 0.5 | ±0.1℃ | Φ250mm, 54W | Stirrer inner thermostat, discharge pipe temperature thermostat, condenser temperature thermostat, reverse phase protection device, low room temperature protection thermostat, high liquid temperature protection thermostat, low liquid temperature protection thermostat, inverter protection device set, high pressure switch, compressor protection thermostat | Restart prevention timer/refrigerant leak detection | 0.55 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC, 60W, 4P | 3 phase AC200/200/220V 50/60Hz | Tank liquid temperature | Tank liquid temperature | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | ON timer: 1~999 hours (set in 1 hour increments) | - | CE compatible | 0.5~200 | 5~45 | 5~50 | |
AKJ189-H |
Available upon quote | 0~100% | DC12/24V | Equivalent to 0.4kW | Cross fin coil type | 1.6/1.8 | Open coil type | Ivory white | 920×360×440 | 1 |
・200V 50Hz: 0.82kW/3.3A ・200V 60Hz: 0.83kW/3.2A ・220V 60Hz: 0.83kW/3.0A |
・200V 50Hz: 1.20kW/3.8A ・200V 60Hz: 1.20kW/3.8A ・220V 60Hz: 1.44kW/4.2A |
0.5 | ±0.1℃ | Φ250mm, 54W | Stirrer inner thermostat, discharge pipe temperature thermostat, condenser temperature thermostat, reverse phase protection device, low room temperature protection thermostat, high liquid temperature protection thermostat, low liquid temperature protection thermostat, inverter protection device set, heating prevention temperature switch, temperature fuse | Restart prevention timer/refrigerant leak detection | 0.55 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC, 60W, 4P | 3 phase AC200/200/220V 50/60Hz | Tank liquid temperature | Tank liquid temperature | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | ON timer: 1~999 hours (set in 1 hour increments) | - | With heater | 0.5~200 | 5~45 | 5~50 | |
AKJ189-Different voltage specifications |
Available upon quote | 0~100% | DC12/24V | Equivalent to 0.4kW | Cross fin coil type | 1.6/1.8 | Open coil type | Ivory white | 920×360×440 | - | Depends on option combination | - | 0.5 | ±0.1℃ | Φ250mm, 54W | Stirrer inner thermostat, discharge pipe temperature thermostat, condenser temperature thermostat, reverse phase protection device, low room temperature protection thermostat, high liquid temperature protection thermostat, low liquid temperature protection thermostat, inverter protection device set (depending on option combination) | Restart prevention timer/refrigerant leak detection | 0.55 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC, 60W, 4P | Depends on option combination | Tank liquid temperature | Tank liquid temperature | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | ON timer: 1~999 hours (set in 1 hour increments) | 2.14kVA | Different voltage | 0.5~200 | 5~45 | 5~50 | |
AKJ359 |
Available upon quote | 0~100% | DC12/24V | Equivalent to 0.75kW | Cross fin coil type | 3.2/3.5 | Open coil type | Ivory white | 1,045×360×440 | - |
・200V 50Hz: 1.37kW/5.2A ・200V 60Hz: 1.38kW/5.1A ・220V 60Hz: 1.39kW/4.8A |
- | 1.2 | ±0.1℃ | Φ300mm, 54W | Stirrer inner thermostat, discharge pipe temperature thermostat, condenser temperature thermostat, reverse phase protection device, low room temperature protection thermostat, high liquid temperature protection thermostat, low liquid temperature protection thermostat, inverter protection device set | Restart prevention timer/refrigerant leak detection | 0.76 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC, 60W, 4P | 3 phase AC200/200/220V 50/60Hz | Tank liquid temperature | Tank liquid temperature | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | ON timer: 1~999 hours (set in 1 hour increments) | - | - | 0.5~200 | 5~45 | 5~50 | |
AKJ359-B |
Available upon quote | 0~100% | DC12/24V | Equivalent to 0.75kW | Cross fin coil type | 3.2/3.5 | Open coil type | Ivory white | 1,045×360×440 | - |
・200V 50Hz: 1.37kW/5.2A ・200V 60Hz: 1.38kW/5.1A ・220V 60Hz: 1.39kW/4.8A |
- | 1.2 | ±0.1℃ | Φ300mm, 54W | Stirrer inner thermostat, discharge pipe temperature thermostat, condenser temperature thermostat, reverse phase protection device, low room temperature protection thermostat, high liquid temperature protection thermostat, low liquid temperature protection thermostat, inverter protection device set, circuit breaker | Restart prevention timer/refrigerant leak detection | 0.76 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC, 60W, 4P | 3 phase AC200/200/220V 50/60Hz | Tank liquid temperature | Tank liquid temperature | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | ON timer: 1~999 hours (set in 1 hour increments) | - | With breaker | 0.5~200 | 5~45 | 5~50 | |
AKJ359-C |
Available upon quote | 0~100% | DC12/24V | Equivalent to 0.75kW | Cross fin coil type | 3.2/3.5 | Open coil type | Ivory white | 1,045×360×440 | - |
・200V 50Hz: 1.37kW/5.2A ・200V 60Hz: 1.38kW/5.1A ・220V 60Hz: 1.39kW/4.8A |
- | 1.2 | ±0.1℃ | Φ300mm, 54W | Stirrer inner thermostat, discharge pipe temperature thermostat, condenser temperature thermostat, reverse phase protection device, low room temperature protection thermostat, high liquid temperature protection thermostat, low liquid temperature protection thermostat, inverter protection device set, high pressure switch, compressor protection thermostat | Restart prevention timer/refrigerant leak detection | 0.76 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC, 60W, 4P | 3 phase AC200/200/220V 50/60Hz | Tank liquid temperature | Tank liquid temperature | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | ON timer: 1~999 hours (set in 1 hour increments) | - | CE compatible | 0.5~200 | 5~45 | 5~50 | |
AKJ359-H |
Available upon quote | 0~100% | DC12/24V | Equivalent to 0.75kW | Cross fin coil type | 3.2/3.5 | Open coil type | Ivory white | 1,045×360×440 | 1 |
・200V 50Hz: 1.37kW/5.2A ・200V 60Hz: 1.38kW/5.1A ・220V 60Hz: 1.39kW/4.8A |
・200V 50Hz: 1.20kW/3.8A ・200V 60Hz: 1.20kW/3.8A ・220V 60Hz: 1.44kW/4.2A |
1.2 | ±0.1℃ | Φ300mm, 54W | Stirrer inner thermostat, discharge pipe temperature thermostat, condenser temperature thermostat, reverse phase protection device, low room temperature protection thermostat, high liquid temperature protection thermostat, low liquid temperature protection thermostat, inverter protection device set, heating prevention temperature switch, temperature fuse | Restart prevention timer/refrigerant leak detection | 0.76 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC, 60W, 4P | 3 phase AC200/200/220V 50/60Hz | Tank liquid temperature | Tank liquid temperature | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | ON timer: 1~999 hours (set in 1 hour increments) | - | With heater | 0.5~200 | 5~45 | 5~50 | |
AKJ359-Different voltage specifications |
Available upon quote | 0~100% | DC12/24V | Equivalent to 0.75kW | Cross fin coil type | 3.2/3.5 | Open coil type | Ivory white | 1,045×360×440 | - | Depends on option combination | - | 1.2 | ±0.1℃ | Φ300mm, 54W | Stirrer inner thermostat, discharge pipe temperature thermostat, condenser temperature thermostat, reverse phase protection device, low room temperature protection thermostat, high liquid temperature protection thermostat, low liquid temperature protection thermostat, inverter protection device set (depending on option combination) | Restart prevention timer/refrigerant leak detection | 0.76 | Compressor rotation speed + electronic expansion valve opening by inverter | 3 phase AC, 60W, 4P | Depends on option combination | Tank liquid temperature | Tank liquid temperature | -9.9~+9.9 relative to standard temperature (0.0 at factory shipment) | 5~50 | Room temperature or aircraft temperature (Factory setting is room temperature: Mode 3) | ON timer: 1~999 hours (set in 1 hour increments) | 2.14kVA | Different voltage | 0.5~200 | 5~45 | 5~50 |
Click on the part number for more information about each product