SSH Console Serial Switch with Environmental MonitoringHandling Company
Wise Co., Ltd.Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Regulatory approval | Environment Operating temperature | Environment Relative humidity during operation and storage | Environment Storage temperature | Power consumption | Dimensions WxDxH (in) | Force | Internal sensor temperature | Internal sensor fan | Guarantee | Compatibility | Logging and buffering | Memory | Network interface | Serial interface signal | Serial interface modem control | Serial interface flow control | Serial interface data transfer rate | Serial Interface Serial Port Connector | Serial interface console port connector | Adapter | RJ45 sensor port | MTBF |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SERIMUX-S-8 |
Available upon quote |
CE, RoHS |
0 to 40℃ |
17~90%, non-condensing |
-30~60℃ |
10W |
16.20 x 9.00 x 1.75 (without included rack mount kit) |
Input voltage: AC 100~240 V, 50~60 Hz (country-specific power cable included) |
0~40℃ application |
- |
Compliant with 2 year manufacturer warranty |
Supports most devices with RS232 serial port |
System logs, user activity event logs, online data buffering |
32 MB flash memory |
Two 10/100 Base-T Ethernet ports with RJ45 Ethernet connectors |
RS232 CTS, DSR, RXD, GND, DCD, TXD, DTR, RTS |
DTR/DSR and RTS/CTS |
Hardware RTS/CTS |
Up to 115.2Kbps between two ports |
RJ45 EIA-232×8 |
RJ45 EIA-232×1 |
Male DB-25F to Female RJ45 |
Two RJ45 modular jacks for connecting NTI temperature/humidity sensors and liquid detection sensors |
43,306 hours |
|
SERIMUX-S-16 |
Available upon quote |
CE, RoHS |
0 to 40℃ |
17~90%, non-condensing |
-30~60℃ |
15W |
16.20 x 9.00 x 1.75 (without included rack mount kit) |
Input voltage: AC 100~240 V, 50~60 Hz (country-specific power cable included) |
0~40℃ application |
- |
Compliant with 2 year manufacturer warranty |
Supports most devices with RS232 serial port |
System logs, user activity event logs, online data buffering |
32 MB flash memory |
Two 10/100 Base-T Ethernet ports with RJ45 Ethernet connectors |
RS232 CTS, DSR, RXD, GND, DCD, TXD, DTR, RTS |
DTR/DSR and RTS/CTS |
Hardware RTS/CTS |
Up to 115.2Kbps between two ports |
RJ45 EIA-232×16 |
RJ45 EIA-232×1 |
Male DB-25F to Female RJ45 |
Two RJ45 modular jacks for connecting NTI temperature/humidity sensors and liquid detection sensors |
108,371 hours |
|
SERIMUX-S-24 |
Available upon quote |
CE, RoHS |
0 to 40℃ |
17~90%, non-condensing |
-30~60℃ |
15W |
17.40 x 10.00 x 1.75 (without included rack mount kit) |
Input voltage: AC 100~240 V, 50~60 Hz (country-specific power cable included) |
0~40℃ application |
Ability to monitor internal fan speed |
Compliant with 2 year manufacturer warranty |
Supports most devices with RS232 serial port |
System logs, user activity event logs, online data buffering |
32 MB flash memory |
Two 10/100 Base-T Ethernet ports with RJ45 Ethernet connectors |
RS232 CTS, DSR, RXD, GND, DCD, TXD, DTR, RTS |
DTR/DSR and RTS/CTS |
Hardware RTS/CTS |
Up to 115.2Kbps between two ports |
RJ45 EIA-232×24 |
RJ45 EIA-232×1 |
Male DB-25F to Female RJ45 |
Two RJ45 modular jacks for connecting NTI temperature/humidity sensors and liquid detection sensors |
44,783 hours |
|
SERIMUX-S-32 |
Available upon quote |
CE, RoHS |
0 to 40℃ |
17~90%, non-condensing |
-30~60℃ |
15W |
17.40 x 10.00 x 1.75 (without included rack mount kit) |
Input voltage: AC 100~240 V, 50~60 Hz (country-specific power cable included) |
0~40℃ application |
Ability to monitor internal fan speed |
Compliant with 2 year manufacturer warranty |
Supports most devices with RS232 serial port |
System logs, user activity event logs, online data buffering |
32 MB flash memory |
Two 10/100 Base-T Ethernet ports with RJ45 Ethernet connectors |
RS232 CTS, DSR, RXD, GND, DCD, TXD, DTR, RTS |
DTR/DSR and RTS/CTS |
Hardware RTS/CTS |
Up to 115.2Kbps between two ports |
RJ45 EIA-232×32 |
RJ45 EIA-232×1 |
Male DB-25F to Female RJ45 |
Two RJ45 modular jacks for connecting NTI temperature/humidity sensors and liquid detection sensors |
100,384 hours |
|
SERIMUX-S-8DP |
Available upon quote |
CE, RoHS |
0 to 40℃ |
17~90%, non-condensing |
-30~60℃ |
10W |
16.20 x 9.00 x 1.75 (without included rack mount kit) |
Input voltage: AC 100~240 V, 50~60 Hz (country-specific power cable included) |
0~40℃ application |
- |
Compliant with 2 year manufacturer warranty |
Supports most devices with RS232 serial port |
System logs, user activity event logs, online data buffering |
32 MB flash memory |
Two 10/100 Base-T Ethernet ports with RJ45 Ethernet connectors |
RS232 CTS, DSR, RXD, GND, DCD, TXD, DTR, RTS |
DTR/DSR and RTS/CTS |
Hardware RTS/CTS |
Up to 115.2Kbps between two ports |
RJ45 EIA-232×8 |
RJ45 EIA-232×1 |
Male DB-25F to Female RJ45 |
Two RJ45 modular jacks for connecting NTI temperature/humidity sensors and liquid detection sensors |
42,980 hours |
|
SERIMUX-S-16DP |
Available upon quote |
CE, RoHS |
0 to 40℃ |
17~90%, non-condensing |
-30~60℃ |
15W |
16.20 x 9.00 x 1.75 (without included rack mount kit) |
Input voltage: AC 100~240 V, 50~60 Hz (country-specific power cable included) |
0~40℃ application |
- |
Compliant with 2 year manufacturer warranty |
Supports most devices with RS232 serial port |
System logs, user activity event logs, online data buffering |
32 MB flash memory |
Two 10/100 Base-T Ethernet ports with RJ45 Ethernet connectors |
RS232 CTS, DSR, RXD, GND, DCD, TXD, DTR, RTS |
DTR/DSR and RTS/CTS |
Hardware RTS/CTS |
Up to 115.2Kbps between two ports |
RJ45 EIA-232×16 |
RJ45 EIA-232×1 |
Male DB-25F to Female RJ45 |
Two RJ45 modular jacks for connecting NTI temperature/humidity sensors and liquid detection sensors |
91,754 hours |
|
SERIMUX-S-24DP |
Available upon quote |
CE, RoHS |
0 to 40℃ |
17~90%, non-condensing |
-30~60℃ |
15W |
17.40 x 10.00 x 1.75 (without included rack mount kit) |
Input voltage: AC 100~240 V, 50~60 Hz (country-specific power cable included) |
0~40℃ application |
Ability to monitor internal fan speed |
Compliant with 2 year manufacturer warranty |
Supports most devices with RS232 serial port |
System logs, user activity event logs, online data buffering |
32 MB flash memory |
Two 10/100 Base-T Ethernet ports with RJ45 Ethernet connectors |
RS232 CTS, DSR, RXD, GND, DCD, TXD, DTR, RTS |
DTR/DSR and RTS/CTS |
Hardware RTS/CTS |
Up to 115.2Kbps between two ports |
RJ45 EIA-232×24 |
RJ45 EIA-232×1 |
Male DB-25F to Female RJ45 |
Two RJ45 modular jacks for connecting NTI temperature/humidity sensors and liquid detection sensors |
42,004 hours |
|
SERIMUX-S-32DP |
Available upon quote |
CE, RoHS |
0 to 40℃ |
17~90%, non-condensing |
-30~60℃ |
15W |
17.40 x 10.00 x 1.75 (without included rack mount kit) |
Input voltage: AC 100~240 V, 50~60 Hz (country-specific power cable included) |
0~40℃ application |
Ability to monitor internal fan speed |
Compliant with 2 year manufacturer warranty |
Supports most devices with RS232 serial port |
System logs, user activity event logs, online data buffering |
32 MB flash memory |
Two 10/100 Base-T Ethernet ports with RJ45 Ethernet connectors |
RS232 CTS, DSR, RXD, GND, DCD, TXD, DTR, RTS |
DTR/DSR and RTS/CTS |
Hardware RTS/CTS |
Up to 115.2Kbps between two ports |
RJ45 EIA-232×32 |
RJ45 EIA-232×1 |
Male DB-25F to Female RJ45 |
Two RJ45 modular jacks for connecting NTI temperature/humidity sensors and liquid detection sensors |
87,420 hours |