Product
Water quality control device WHJ Mutual diagnosis type automatic residual chlorine concentration control deviceHandling Company
Shoei Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | Communication function | Communication protocol | Concentration display range | Concentration sensor | Control range | Electrode cleaning method | Measurement method | Measurement target | Measurement water conditions | Minimum resolution | Power consumption 50Hz | Power consumption 60Hz | Power supply | Standard dimensions (mm) | Storage environment for unused items | Usage environment | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
WHJ-P-1 |
Available upon quote | RS485 communication port 1 channel | Shoei protocol, (communication data: current concentration, status, concentration calibration, parameter change, control error) | 0.00~5.00ppm (high concentration 5.00ppm) | WHJ-01 concentration sensor, cable length 1.8m can be extended up to 5m with option | 0.00~3.00ppm (high concentration 5.00ppm) | Glass bead cleaning and electric cleaning | Polarographic method | Free residual chlorine in bathtub and pool water | Temperature: 0~50℃, Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 | 0.01ppm | 0.11kW/0.11kVA | 0.15kW/0.15kVA | AC100V 50/60Hz | W397×L297×H1,000 | Ambient temperature: 0~50℃ (no freezing), ambient humidity: 35~85%RH (no condensation) | Ambient temperature: 0~50℃ (no freezing), ambient humidity: 35~85%RH (no condensation) | 23kg | |
WHJ-P-2 |
Available upon quote | RS485 communication port 1 channel | Shoei protocol, (communication data: current concentration, status, concentration calibration, parameter change, control error) | 0.00~5.00ppm (high concentration 5.00ppm) | WHJ-01 concentration sensor, cable length 1.8m can be extended up to 5m with option | 0.00~3.00ppm (high concentration 5.00ppm) | Glass bead cleaning and electric cleaning | Polarographic method | Free residual chlorine in bathtub and pool water | Temperature: 0~50℃, Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 | 0.01ppm | 0.11kW/0.11kVA | 0.15kW/0.15kVA | AC200V 50/60Hz | W397×L297×H1,000 | Ambient temperature: 0~50℃ (no freezing), ambient humidity: 35~85%RH (no condensation) | Ambient temperature: 0~50℃ (no freezing), ambient humidity: 35~85%RH (no condensation) | 23kg |
Click on the part number for more information about each product