Water quality control device HJ Automatic residual chlorine concentration control device with data log Hyper Pure-HJ-P-2
Water quality control device HJ Automatic residual chlorine concentration control device with data log Hyper Pure-Shoei Co., Ltd.

Water quality control device HJ Automatic residual chlorine concentration control device with data log Hyper Pure
Shoei Co., Ltd.


About This Product

■Applications It can be used to measure and control the residual chlorine concentration in bath water, pool water, etc. (tap water, hot spring water, well water). ■Adoption of automatic sensitivity adjustment control method Enables more precise control in place of the conventional time-division control method. ■Intermittent timer operation function When automatic control is difficult, the built-in intermittent timer allows for injecting chemical liquid. ■RS485 communication remote monitoring system The status of the device can be monitored from the outside, and it is possible to calibrate concentrations, change parameter values, and not only generate but also cancel alarms when errors occur. ■Automatic backup function in case of error When an error occurs, it automatically switches to intermittent operation to ensure the safety of the bathtub. ■Expansion of concentration control range Can be set up to 3.0ppm. This makes it possible to accommodate foreign-affiliated facilities. ■Automatic high concentration control operation High concentration operation is possible at the value automatically set by key operation. The difference between the current concentration and the high concentration setting value is automatically calculated, and the optimal chlorine injection amount is controlled while increasing to the high concentration setting value. After reaching the set value, control will stop until the value drops to the normal set value. It is also possible to set the start time and concentration value for each day of the week using the weekly timer (can be set from 2.0 to 5.0ppm) ■SD memory card type data logger system Traditionally, recording paper needed to be replaced once every 1 to 2 months, but if a 2GB SD card is used as the recording medium, recording at 5-minute intervals can be saved for over 10 years. ■Weekly timer function Equipped with weekly timer function, it is possible to set operating time and high concentration operating time. Data logger automatically records date and time for easy management. ■Temperature measurement function Equipped with a temperature measurement function, it is possible to display the temperature. (Separate temperature display must be installed) Reduces costs such as wiring costs and equipment costs for measuring instruments. ■Control parameter setting auxiliary function When you enter the bathtub capacity and chemical pump discharge amount, a trial run is automatically performed and assistance is provided for setting control parameters. ■Summary This is an automatic residual chlorine concentration control device that has many functions to protect the safety of pools and hot bath facilities. Highly accurate residual chlorine concentration measurements and optimal control methods maintain safe residual chlorine concentrations. Please use it to prevent Legionnaires' disease. ■Standard delivery date 20 days

  • Product

    Water quality control device HJ Automatic residual chlorine concentration control device with data log Hyper Pure

Share this product


310+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

4 Models of Water quality control device HJ Automatic residual chlorine concentration control device with data log Hyper Pure

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Concentration display range Concentration sensor Control range Data logger Display Electrode cleaning method Measurement method Measurement water conditions Power (V) Power consumption (W) / (VA) 50Hz Power consumption (W) / (VA) 60Hz Residual chlorine meter Sampling pump Standard dimensions (mm) Usage environment Weekly timer Weight (kg)
Water quality control device HJ Automatic residual chlorine concentration control device with data log Hyper Pure-Part Number-HJ-P-2

HJ-P-2

Available upon quote 0.00~4.09ppm (high concentration 6.09ppm) HJ-01 concentration sensor, cable length 1.8m can be extended up to 5m with option 0.00~3.00ppm (high concentration 5.00ppm) Recording target: Year, month, date, time, measured value, concentration setting, alarm error number, operating status, etc. Recording medium: SD memory card 1 time/10 minutes (53,060 minutes), Recommended card capacity: 512MB LED (green) Chlorine concentration: 0.00~6.09ppm (more than 6.10ppm is displayed as “⁻⁻,⁻⁻”), LED (red) Concentration setting value (Max. 3.0ppm) High concentration setting value (Max. 5.0ppm) Glass bead cleaning and electric cleaning Polarographic method Temperature: 0~45℃, Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 AC200V 113.40/113.40 13.40/13.40 HJ-01 Can be W355×L238×H900 Ambient temperature: 0~50℃ (no freezing), ambient humidity: 35~85%RH (no condensation) Setting target: automatic operation time, high concentration operation start time, intermittent timer ON/OFF time, storage period: 10 years or more, setting method: Depends on internal parameters 14
Water quality control device HJ Automatic residual chlorine concentration control device with data log Hyper Pure-Part Number-HJ-2

HJ-2

Available upon quote 0.00~4.09ppm (high concentration 6.09ppm) HJ-01 concentration sensor, cable length 1.8m can be extended up to 5m with option 0.00~3.00ppm (high concentration 5.00ppm) Recording target: Year, month, date, time, measured value, concentration setting, alarm error number, operating status, etc. Recording medium: SD memory card 1 time/10 minutes (53,060 minutes), Recommended card capacity: 512MB LED (green) Chlorine concentration: 0.00~6.09ppm (more than 6.10ppm is displayed as “⁻⁻,⁻⁻”), LED (red) Concentration setting value (Max. 3.0ppm) High concentration setting value (Max. 5.0ppm) Glass bead cleaning and electric cleaning Polarographic method Temperature: 0~45℃, Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 AC200V 148.40/148.40 13.40/13.40 HJ-01 - W355×L238×H900 Ambient temperature: 0~50℃ (no freezing), ambient humidity: 35~85%RH (no condensation) Setting target: automatic operation time, high concentration operation start time, intermittent timer ON/OFF time, storage period: 10 years or more, setting method: Depends on internal parameters 12
Water quality control device HJ Automatic residual chlorine concentration control device with data log Hyper Pure-Part Number-HJ-P-1

HJ-P-1

Available upon quote 0.00~4.09ppm (high concentration 6.09ppm) HJ-01 concentration sensor, cable length 1.8m can be extended up to 5m with option 0.00~3.00ppm (high concentration 5.00ppm) Recording target: Year, month, date, time, measured value, concentration setting, alarm error number, operating status, etc. Recording medium: SD memory card 1 time/10 minutes (53,060 minutes), Recommended card capacity: 512MB LED (green) Chlorine concentration: 0.00~6.09ppm (more than 6.10ppm is displayed as “⁻⁻,⁻⁻”), LED (red) Concentration setting value (Max. 3.0ppm) High concentration setting value (Max. 5.0ppm) Glass bead cleaning and electric cleaning Polarographic method Temperature: 0~45℃, Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 AC100V 109.87/109.87 144.87/144.87 HJ-01 Can be W355×L238×H900 Ambient temperature: 0~50℃ (no freezing), ambient humidity: 35~85%RH (no condensation) Setting target: automatic operation time, high concentration operation start time, intermittent timer ON/OFF time, storage period: 10 years or more, setting method: Depends on internal parameters 14
Water quality control device HJ Automatic residual chlorine concentration control device with data log Hyper Pure-Part Number-HJ-1

HJ-1

Available upon quote 0.00~4.09ppm (high concentration 6.09ppm) HJ-01 concentration sensor, cable length 1.8m can be extended up to 5m with option 0.00~3.00ppm (high concentration 5.00ppm) Recording target: Year, month, date, time, measured value, concentration setting, alarm error number, operating status, etc. Recording medium: SD memory card 1 time/10 minutes (53,060 minutes), Recommended card capacity: 512MB LED (green) Chlorine concentration: 0.00~6.09ppm (more than 6.10ppm is displayed as “⁻⁻,⁻⁻”), LED (red) Concentration setting value (Max. 3.0ppm) High concentration setting value (Max. 5.0ppm) Glass bead cleaning and electric cleaning Polarographic method Temperature: 0~45℃, Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 AC100V 9.87/9.87 9.87/9.87 HJ-01 - W355×L238×H900 Ambient temperature: 0~50℃ (no freezing), ambient humidity: 35~85%RH (no condensation) Setting target: automatic operation time, high concentration operation start time, intermittent timer ON/OFF time, storage period: 10 years or more, setting method: Depends on internal parameters 12

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Shoei Co., Ltd.


View more products of Shoei Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree