Water quality control device NJ Automatic residual chlorine concentration control device New JunHandling Company
Shoei Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Power supply | Electrode cleaning method | Display range | Display | Concentration sensor | Measurement water conditions | Measurement method | Power consumption (W) / (VA) | Residual chlorine meter | Control range | Usage environment | Sampling pump | Recorder | Format |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NJ-PD-1 50Hz |
Available upon quote |
AC100V |
Glass bead cleaning and electric cleaning |
0.00~3.09ppm |
LED (green) Chlorine concentration: 0.00~3.09ppm (“⁻⁻,⁻⁻” is displayed for 3.10ppm or more), LED (red) Displays the set concentration, and displays an alarm when an abnormality occurs (alarm number for concentration abnormality or control abnormality is displayed) display) |
CS-05 concentration sensor, cable length 1.8m, can be extended up to 5m with option, separated from power line by 300mm or more |
Temperature: 0~45℃, Flow rate: 2.0~3.0L/min (proper flow rate is 2.5L/min), Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 |
Polarographic method, accuracy ±5% (0.00~2.00ppm) |
108.40/108.40 |
CS-05 |
0.00~2.00ppm |
Ambient temperature: 0~50℃ (no condensation), ambient humidity: 35~85%RH (no condensation) |
Can be |
Can be |
- | |
NJ-PD-1 60Hz |
Available upon quote |
AC100V |
Glass bead cleaning and electric cleaning |
0.00~3.09ppm |
LED (green) Chlorine concentration: 0.00~3.09ppm (“⁻⁻,⁻⁻” is displayed for 3.10ppm or more), LED (red) Displays the set concentration, and displays an alarm when an abnormality occurs (alarm number for concentration abnormality or control abnormality is displayed) display) |
CS-05 concentration sensor, cable length 1.8m, can be extended up to 5m with option, separated from power line by 300mm or more |
Temperature: 0~45℃, Flow rate: 2.0~3.0L/min (proper flow rate is 2.5L/min), Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 |
Polarographic method, accuracy ±5% (0.00~2.00ppm) |
143.40/143.40 |
CS-05 |
0.00~2.00ppm |
Ambient temperature: 0~50℃ (no condensation), ambient humidity: 35~85%RH (no condensation) |
Can be |
Can be |
- | |
NJ-PD-1L 50Hz |
Available upon quote |
AC100V |
Glass bead cleaning and electric cleaning |
0.00~3.09ppm |
LED (green) Chlorine concentration: 0.00~3.09ppm (“⁻⁻,⁻⁻” is displayed for 3.10ppm or more), LED (red) Displays the set concentration, and displays an alarm when an abnormality occurs (alarm number for concentration abnormality or control abnormality is displayed) display) |
CS-05 concentration sensor, cable length 1.8m, can be extended up to 5m with option, separated from power line by 300mm or more |
Temperature: 0~45℃, Flow rate: 2.0~3.0L/min (proper flow rate is 2.5L/min), Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 |
Polarographic method, accuracy ±5% (0.00~2.00ppm) |
108.40/108.40 |
CS-05 |
0.00~2.00ppm |
Ambient temperature: 0~50℃ (no condensation), ambient humidity: 35~85%RH (no condensation) |
Can be |
Can be |
Integrated type |
|
NJ-PD-1L 60Hz |
Available upon quote |
AC100V |
Glass bead cleaning and electric cleaning |
0.00~3.09ppm |
LED (green) Chlorine concentration: 0.00~3.09ppm (“⁻⁻,⁻⁻” is displayed for 3.10ppm or more), LED (red) Displays the set concentration, and displays an alarm when an abnormality occurs (alarm number for concentration abnormality or control abnormality is displayed) display) |
CS-05 concentration sensor, cable length 1.8m, can be extended up to 5m with option, separated from power line by 300mm or more |
Temperature: 0~45℃, Flow rate: 2.0~3.0L/min (proper flow rate is 2.5L/min), Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 |
Polarographic method, accuracy ±5% (0.00~2.00ppm) |
143.40/143.40 |
CS-05 |
0.00~2.00ppm |
Ambient temperature: 0~50℃ (no condensation), ambient humidity: 35~85%RH (no condensation) |
Can be |
Can be |
Integrated type |
|
NJ-D-1 50Hz |
Available upon quote |
AC100V |
Glass bead cleaning and electric cleaning |
0.00~3.09ppm |
LED (green) Chlorine concentration: 0.00~3.09ppm (“⁻⁻,⁻⁻” is displayed for 3.10ppm or more), LED (red) Displays the set concentration, and displays an alarm when an abnormality occurs (alarm number for concentration abnormality or control abnormality is displayed) display) |
CS-05 concentration sensor, cable length 1.8m, can be extended up to 5m with option, separated from power line by 300mm or more |
Temperature: 0~45℃, Flow rate: 2.0~3.0L/min (proper flow rate is 2.5L/min), Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 |
Polarographic method, accuracy ±5% (0.00~2.00ppm) |
8.40/8.40 |
CS-05 |
0.00~2.00ppm |
Ambient temperature: 0~50℃ (no condensation), ambient humidity: 35~85%RH (no condensation) |
- |
Can be |
- | |
NJ-D-1 60Hz |
Available upon quote |
AC100V |
Glass bead cleaning and electric cleaning |
0.00~3.09ppm |
LED (green) Chlorine concentration: 0.00~3.09ppm (“⁻⁻,⁻⁻” is displayed for 3.10ppm or more), LED (red) Displays the set concentration, and displays an alarm when an abnormality occurs (alarm number for concentration abnormality or control abnormality is displayed) display) |
CS-05 concentration sensor, cable length 1.8m, can be extended up to 5m with option, separated from power line by 300mm or more |
Temperature: 0~45℃, Flow rate: 2.0~3.0L/min (proper flow rate is 2.5L/min), Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 |
Polarographic method, accuracy ±5% (0.00~2.00ppm) |
8.40/8.40 |
CS-05 |
0.00~2.00ppm |
Ambient temperature: 0~50℃ (no condensation), ambient humidity: 35~85%RH (no condensation) |
- |
Can be |
- | |
NJ-D-1L 50Hz |
Available upon quote |
AC100V |
Glass bead cleaning and electric cleaning |
0.00~3.09ppm |
LED (green) Chlorine concentration: 0.00~3.09ppm (“⁻⁻,⁻⁻” is displayed for 3.10ppm or more), LED (red) Displays the set concentration, and displays an alarm when an abnormality occurs (alarm number for concentration abnormality or control abnormality is displayed) display) |
CS-05 concentration sensor, cable length 1.8m, can be extended up to 5m with option, separated from power line by 300mm or more |
Temperature: 0~45℃, Flow rate: 2.0~3.0L/min (proper flow rate is 2.5L/min), Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 |
Polarographic method, accuracy ±5% (0.00~2.00ppm) |
8.40/8.40 |
CS-05 |
0.00~2.00ppm |
Ambient temperature: 0~50℃ (no condensation), ambient humidity: 35~85%RH (no condensation) |
- |
Can be |
Integrated type |
|
NJ-D-1L 60Hz |
Available upon quote |
AC100V |
Glass bead cleaning and electric cleaning |
0.00~3.09ppm |
LED (green) Chlorine concentration: 0.00~3.09ppm (“⁻⁻,⁻⁻” is displayed for 3.10ppm or more), LED (red) Displays the set concentration, and displays an alarm when an abnormality occurs (alarm number for concentration abnormality or control abnormality is displayed) display) |
CS-05 concentration sensor, cable length 1.8m, can be extended up to 5m with option, separated from power line by 300mm or more |
Temperature: 0~45℃, Flow rate: 2.0~3.0L/min (proper flow rate is 2.5L/min), Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 |
Polarographic method, accuracy ±5% (0.00~2.00ppm) |
8.40/8.40 |
CS-05 |
0.00~2.00ppm |
Ambient temperature: 0~50℃ (no condensation), ambient humidity: 35~85%RH (no condensation) |
- |
Can be |
Integrated type |
|
NJ-P-1 50Hz |
Available upon quote |
AC100V |
Glass bead cleaning and electric cleaning |
0.00~3.09ppm |
LED (green) Chlorine concentration: 0.00~3.09ppm (“⁻⁻,⁻⁻” is displayed for 3.10ppm or more), LED (red) Displays the set concentration, and displays an alarm when an abnormality occurs (alarm number for concentration abnormality or control abnormality is displayed) display) |
CS-05 concentration sensor, cable length 1.8m, can be extended up to 5m with option, separated from power line by 300mm or more |
Temperature: 0~45℃, Flow rate: 2.0~3.0L/min (proper flow rate is 2.5L/min), Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 |
Polarographic method, accuracy ±5% (0.00~2.00ppm) |
104.90/104.90 |
CS-05 |
0.00~2.00ppm |
Ambient temperature: 0~50℃ (no condensation), ambient humidity: 35~85%RH (no condensation) |
Can be |
- | - | |
NJ-P-1 60Hz |
Available upon quote |
AC100V |
Glass bead cleaning and electric cleaning |
0.00~3.09ppm |
LED (green) Chlorine concentration: 0.00~3.09ppm (“⁻⁻,⁻⁻” is displayed for 3.10ppm or more), LED (red) Displays the set concentration, and displays an alarm when an abnormality occurs (alarm number for concentration abnormality or control abnormality is displayed) display) |
CS-05 concentration sensor, cable length 1.8m, can be extended up to 5m with option, separated from power line by 300mm or more |
Temperature: 0~45℃, Flow rate: 2.0~3.0L/min (proper flow rate is 2.5L/min), Pressure: 0.01~0.30MPa, pH value: 5.8~9.0 |
Polarographic method, accuracy ±5% (0.00~2.00ppm) |
139.90/139.90 |
CS-05 |
0.00~2.00ppm |
Ambient temperature: 0~50℃ (no condensation), ambient humidity: 35~85%RH (no condensation) |
Can be |
- | - |
Click on the part number for more information about each product