All Categories

History

Various vibration switches PRO-PRO440
Various vibration switches PRO-PRO6000
Various vibration switches PRO-PRO450
Various vibration switches PRO-BATROSS Co., Ltd.

Various vibration switches PRO
BATROSS Co., Ltd.


About This Product

■Features

The "PRO™" series includes "PRO440", "PRO450", and "PRO6000". The ``PRO'' series has almost the same functions, the only difference being the shape of the housing and the size of the connections. It can also be installed on or near equipment in typical industrial plant explosion-proof areas and environmental conditions. Each vibration switch in the PRO series can be configured using the PRO setting software connected to the USB port or the switch's built-in keypad and display. The ``PRO'' series has a built-in anti-vibration function that allows adjustment of alarm settings in 1 step (up to 2 steps as an option) and is also compatible with electronic/mechanical relays. Alarm settings and start-up delays can be programmed independently, and in addition to resetting the unit, switching routes and resetting can be performed using the remote control. The 4-20mA output signal and the output signal from the output terminal of the converter allow connection to plant control systems and setting display instruments. The standard display with status LED lamp and two-line alphanumeric display allows you to check vibration levels, alarm settings, and sensor status on-site. Enclosure cannot be used with display window. To use the display window, you need to remove the housing. It is mainly lined up as an application for upgrading "PRO450". By replacing the housing rather than just the internal unit, the nameplate affixed to the housing includes the serial number, part number, and detailed information for the PRO450 being replaced. If both the display window and the explosion-proof area (Div1/Zone 1) are required, the PRO6000 is used instead of the PRO450. "PRO6000" is smaller than "PRO450" and can be installed with fixing screws. The optional mounting bracket can be used with "Flat Base Plate 7084-001", but the mounting hole positions are different from "PRO450", so new holes must be drilled on the mounting surface.

  • Product

    Various vibration switches PRO

Share this product


280+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

3 Models of Various vibration switches PRO

Click on the part number for more information about each product

Image Part Number Price (excluding tax) Weight Certification Housing material Coating Operating environment Waterproof standard Operating environment Humidity Operating environment Vibration Operating environment Operating temperature Output converter power supply Output relay Output buffered converter Output display Output keypad Output LED display “Alarm” lamp Output LED display “OK” lamp Output LED display “BYPASS” lamp Output DC4~20mA Input power terminal rating Input power Input power consumption Input Maximum signal amplitude Input Corresponding input value Input reset Input Full scale range External speed sensor Input Full-scale range External accelerometer Input Full Scale Range Internal Accelerometer Input Full scale range DC4~20mA converter Input bypass Input impedance Number of input channels
Various vibration switches PRO-Part Number-PRO440

PRO440

Available upon quote

Approximately 1.8kg

EMC:FCC47CFR, 15-B, classA, ANSIC63.4, CSA:CLASSⅠ, DIV2, (B-D), T4, CLASSⅡ, DIV2, (F, G), T4

Copper-free aluminum casting

Epoxy powder coating (blue)

NEMA4X/IP65

100%

≦10G (If the vibration exceeds 10G when measured on-site, install the PRO Switch remotely using an external sensor.)

-40~+70℃

DC24V@25mA (4-20mA-type), DC24V@4mA (rated current & piezo speed), DC12V bias voltage (moving coil speed)

1 unit (2 units optional), SPDT (C type), minimum switching capacity DC100mA@DC5V, maximum capacity AC2,500VA/10A@AV250V, DC5A@DC100V, normally open/closed mutual use

Connection terminal: Inside the PRO housing, BNC terminal: Inside the PRO450 housing, Impedance: 1kΩ, Short protection circuit included, Accuracy: ±5% (measured value), 3dB bandwidth: 20kHz, Cable movable: Maximum length 305m

8 characters x 2 lines, 4 x 7 green dot character display, Resolution: 5 pixels, Displays instantaneous values ​​and their units, You can access the settings menu to change the display and settings, and reset them on the spot.

4 membrane keypad, ``→'' ``↓'' ``MENU'' ``ENTER''

Yellow: In alarm, Red: Shutdown (dual relay only), Off: Not in alarm

Green: Sensor connection OK, Red: Sensor connection NG, Off: SW is not powered on.

Red: SW is in bypass mode, off: SW is in non-bypass mode

Number of outputs: 1, Accuracy: ±1%/full scale, 4mA±0.25mA@minimum, Power supply: DC24V, Short protection circuit included, Dead band current: 3.8mA, Maximum output DC20mA (100%F.S.)

Nominal current 17.5A, maximum load current 22A, nominal voltage AC250V, rated voltage AC320V, insulation polyimide, flame retardant (UL94) V0

AC85~230V/50~60Hz, DC24V (The input power supply must be specified at the time of ordering, and the power supply specifications cannot be changed after installation.)

6W or less

AC5V (p-p): All mV sensor input, DC20mA: All converter input

Acceleration, velocity, integrated acceleration, impact force, DC4~20mA

Reset retention alarm. Use the alarm reset feature to reset in the field via keypad or display. Remote reset is possible if there is not enough RST terminal temporarily.

20~127mm/sec

50~500m/sec^2, 20~117mm/sec

50~100m/sec^2, 20~76mm/sec

-999.9~+999.9

It is energized by shorting the BYP terminal. Bypass status is maintained as long as the terminals continue to be shorted. Monitoring will resume when the short is removed.

Moving coil speed (configurable): 10kΩ, 100kΩ, constant current sensor: 4mA bias (automatically adjusted to maintain current), DC4~20mA converter: 100Ω

1

Various vibration switches PRO-Part Number-PRO6000

PRO6000

Available upon quote

Approximately 1.8kg

EMC:FCC47CFR, 15-B, classA, ANSIC63.4, CSA:CLASSⅠ, DIV1, (B-D), T4A, CLASSⅡ, DIV1, (E-G), T4A

Copper-free aluminum casting

Epoxy powder coating (blue)

NEMA4, explosion-proof

100%

≦10G (If the vibration exceeds 10G when measured on-site, install the PRO Switch remotely using an external sensor.)

-40~+70℃

DC24V@25mA (4-20mA-type), DC24V@4mA (rated current & piezo speed), DC12V bias voltage (moving coil speed)

1 unit (2 units optional), SPDT (C type), minimum switching capacity DC100mA@DC5V, maximum capacity AC2,500VA/10A@AV250V, DC5A@DC100V, normally open/closed mutual use

Connection terminal: Inside the PRO housing, BNC terminal: Inside the PRO450 housing, Impedance: 1kΩ, Short protection circuit included, Accuracy: ±5% (measured value), 3dB bandwidth: 20kHz, Cable movable: Maximum length 305m

8 characters x 2 lines, 4 x 7 green dot character display, Resolution: 5 pixels, Displays instantaneous values ​​and their units, You can access the settings menu to change the display and settings, and reset them on the spot.

4 membrane keypad, ``→'' ``↓'' ``MENU'' ``ENTER''

Yellow: In alarm, Red: Shutdown (dual relay only), Off: Not in alarm

Green: Sensor connection OK, Red: Sensor connection NG, Off: SW is not powered on.

Red: SW is in bypass mode, off: SW is in non-bypass mode

Number of outputs: 1, Accuracy: ±1%/full scale, 4mA±0.25mA@minimum, Power supply: DC24V, Short protection circuit included, Dead band current: 3.8mA, Maximum output DC20mA (100%F.S.)

Nominal current 17.5A, maximum load current 22A, nominal voltage AC250V, rated voltage AC320V, insulation polyimide, flame retardant (UL94) V0

AC85~230V/50~60Hz, DC24V (The input power supply must be specified at the time of ordering, and the power supply specifications cannot be changed after installation.)

6W or less

AC5V (p-p): All mV sensor input, DC20mA: All converter input

Acceleration, velocity, integrated acceleration, impact force, DC4~20mA

Reset retention alarm. Use the alarm reset feature to reset in the field via keypad or display. Remote reset is possible if there is not enough RST terminal temporarily.

20~127mm/sec

50~500m/sec^2, 20~117mm/sec

50~100m/sec^2, 20~76mm/sec

-999.9~+999.9

It is energized by shorting the BYP terminal. Bypass status is maintained as long as the terminals continue to be shorted. Monitoring will resume when the short is removed.

Moving coil speed (configurable): 10kΩ, 100kΩ, constant current sensor: 4mA bias (automatically adjusted to maintain current), DC4~20mA converter: 100Ω

1

Various vibration switches PRO-Part Number-PRO450

PRO450

Available upon quote

Approximately 1.8kg

EMC:FCC47CFR, 15-B, classA, ANSIC63.4, CSA/UL:CLASSⅠ, DIV1, (GROUP:B-D) , CLASSⅡ, DIV1, (GROUP:E-G)

Copper-free aluminum casting

Painted (gray) (Optionally, colored epoxy resin coating is also available. The housing is NEMA4 level regardless of whether or not it is coated with epoxy resin.)

NEMA4X/IP65, explosion-proof

100%

≦10G (If the vibration exceeds 10G when measured on-site, install the PRO Switch remotely using an external sensor.)

-40~+70℃

DC24V@25mA (4-20mA-type), DC24V@4mA (rated current & piezo speed), DC12V bias voltage (moving coil speed)

1 unit (2 units optional), SPDT (C type), minimum switching capacity DC100mA@DC5V, maximum capacity AC2,500VA/10A@AV250V, DC5A@DC100V, normally open/closed mutual use

Connection terminal: Inside the PRO housing, BNC terminal: Inside the PRO450 housing, Impedance: 1kΩ, Short protection circuit included, Accuracy: ±5% (measured value), 3dB bandwidth: 20kHz, Cable movable: Maximum length 305m

8 characters x 2 lines, 4 x 7 green dot character display, Resolution: 5 pixels, Displays instantaneous values ​​and their units, You can access the settings menu to change the display and settings, and reset them on the spot.

4 membrane keypad, ``→'' ``↓'' ``MENU'' ``ENTER''

Yellow: In alarm, Red: Shutdown (dual relay only), Off: Not in alarm

Green: Sensor connection OK, Red: Sensor connection NG, Off: SW is not powered on.

Red: SW is in bypass mode, off: SW is in non-bypass mode

Number of outputs: 1, Accuracy: ±1%/full scale, 4mA±0.25mA@minimum, Power supply: DC24V, Short protection circuit included, Dead band current: 3.8mA, Maximum output DC20mA (100%F.S.)

Nominal current 17.5A, maximum load current 22A, nominal voltage AC250V, rated voltage AC320V, insulation polyimide, flame retardant (UL94) V0

AC85~230V/50~60Hz, DC24V (The input power supply must be specified at the time of ordering, and the power supply specifications cannot be changed after installation.)

6W or less

AC5V (p-p): All mV sensor input, DC20mA: All converter input

Acceleration, velocity, integrated acceleration, impact force, DC4~20mA

Reset retention alarm. Use the alarm reset feature to reset in the field via keypad or display. Remote reset is possible if there is not enough RST terminal temporarily.

20~127mm/sec

50~500m/sec^2, 20~117mm/sec

50~100m/sec^2, 20~76mm/sec

-999.9~+999.9

It is energized by shorting the BYP terminal. Bypass status is maintained as long as the terminals continue to be shorted. Monitoring will resume when the short is removed.

Moving coil speed (configurable): 10kΩ, 100kΩ, constant current sensor: 4mA bias (automatically adjusted to maintain current), DC4~20mA converter: 100Ω

1

Click on the part number for more information about each product

Other products of BATROSS Co., Ltd.

Reviews shown here are reviews of companies.


View more products of BATROSS Co., Ltd.

About Company Handling This Product