Product
3T00Series for ultra-low currentHandling Company
SGM Co., Ltd.Categories
Items marked with have different values depending on the model number.
Click on the part number for more information about each product
Product Image | Part Number | Price (excluding tax) | B/M terminal | Circuit | Electrical life | Initial contact resistance | Initial insulation resistance | Mechanical life | Operating temperature range | P/C terminal | R/A terminal | Rating | V/M terminal | W/W terminal | Withstand voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3T100DG |
Available upon quote | 3T100DG-B/M | Monopolar | Capable of opening and closing operations 100,000 times. | 50mΩ or less at DC2V~4V1A. | DC500V 1,000MΩ or more. | Capable of opening and closing operations 100,000 times. | -20℃~+80℃ | 3T100DG-P/C | 3T100DG-R/A | 50mA 28V DC | 3T100DG-V/M | 3T100DG-W/W | 1,000V AC for 1 minute (between terminals and terminals), 1,500V AC for 1 minute (between terminals and ground) | |
3T100EG |
Available upon quote | 3T100EG-B/M | Monopolar | Capable of opening and closing operations 100,000 times. | 50mΩ or less at DC2V~4V1A. | DC500V 1,000MΩ or more. | Capable of opening and closing operations 100,000 times. | -20℃~+80℃ | 3T100EG-P/C | 3T100EG-R/A | 50mA 28V DC | 3T100EG-V/M | 3T100EG-W/W | 1,000V AC for 1 minute (between terminals and terminals), 1,500V AC for 1 minute (between terminals and ground) | |
3T100FG |
Available upon quote | 3T100FG-B/M | Monopolar | Capable of opening and closing operations 100,000 times. | 50mΩ or less at DC2V~4V1A. | DC500V 1,000MΩ or more. | Capable of opening and closing operations 100,000 times. | -20℃~+80℃ | 3T100FG-P/C | 3T100FG-R/A | 50mA 28V DC | 3T100FG-V/M | 3T100FG-W/W | 1,000V AC for 1 minute (between terminals and terminals), 1,500V AC for 1 minute (between terminals and ground) | |
3T100GG |
Available upon quote | 3T100GG-B/M | Monopolar | Capable of opening and closing operations 100,000 times. | 50mΩ or less at DC2V~4V1A. | DC500V 1,000MΩ or more. | Capable of opening and closing operations 100,000 times. | -20℃~+80℃ | 3T100GG-P/C | 3T100GG-R/A | 50mA 28V DC | 3T100GG-V/M | 3T100GG-W/W | 1,000V AC for 1 minute (between terminals and terminals), 1,500V AC for 1 minute (between terminals and ground) | |
3T100HG |
Available upon quote | 3T100HG-B/M | Monopolar | Capable of opening and closing operations 100,000 times. | 50mΩ or less at DC2V~4V1A. | DC500V 1,000MΩ or more. | Capable of opening and closing operations 100,000 times. | -20℃~+80℃ | 3T100HG-P/C | 3T100HG-R/A | 50mA 28V DC | 3T100HG-V/M | 3T100HG-W/W | 1,000V AC for 1 minute (between terminals and terminals), 1,500V AC for 1 minute (between terminals and ground) | |
3T200NG |
Available upon quote | 3T200NG-B/M | 2 poles | Capable of opening and closing operations 100,000 times. | 50mΩ or less at DC2V~4V1A. | DC500V 1,000MΩ or more. | Capable of opening and closing operations 100,000 times. | -20℃~+80℃ | 3T200NG-P/C | 3T200NG-R/A | 50mA 28V DC | 3T200NG-V/M | 3T200NG-W/W | 1,000V AC for 1 minute (between terminals and terminals), 1,500V AC for 1 minute (between terminals and ground) | |
3T200PG |
Available upon quote | 3T200PG-B/M | 2 poles | Capable of opening and closing operations 100,000 times. | 50mΩ or less at DC2V~4V1A. | DC500V 1,000MΩ or more. | Capable of opening and closing operations 100,000 times. | -20℃~+80℃ | 3T200PG-P/C | 3T200PG-R/A | 50mA 28V DC | 3T200PG-V/M | 3T200PG-W/W | 1,000V AC for 1 minute (between terminals and terminals), 1,500V AC for 1 minute (between terminals and ground) | |
3T200RG |
Available upon quote | 3T200RG-B/M | 2 poles | Capable of opening and closing operations 100,000 times. | 50mΩ or less at DC2V~4V1A. | DC500V 1,000MΩ or more. | Capable of opening and closing operations 100,000 times. | -20℃~+80℃ | 3T200RG-P/C | 3T200RG-R/A | 50mA 28V DC | 3T200RG-V/M | 3T200RG-W/W | 1,000V AC for 1 minute (between terminals and terminals), 1,500V AC for 1 minute (between terminals and ground) | |
3T200SG |
Available upon quote | 3T200SG-B/M | 2 poles | Capable of opening and closing operations 100,000 times. | 50mΩ or less at DC2V~4V1A. | DC500V 1,000MΩ or more. | Capable of opening and closing operations 100,000 times. | -20℃~+80℃ | 3T200SG-P/C | 3T200SG-R/A | 50mA 28V DC | 3T200SG-V/M | 3T200SG-W/W | 1,000V AC for 1 minute (between terminals and terminals), 1,500V AC for 1 minute (between terminals and ground) | |
3T200TG |
Available upon quote | 3T200TG-B/M | 2 poles | Capable of opening and closing operations 100,000 times. | 50mΩ or less at DC2V~4V1A. | DC500V 1,000MΩ or more. | Capable of opening and closing operations 100,000 times. | -20℃~+80℃ | 3T200TG-P/C | 3T200TG-R/A | 50mA 28V DC | 3T200TG-V/M | 3T200TG-W/W | 1,000V AC for 1 minute (between terminals and terminals), 1,500V AC for 1 minute (between terminals and ground) |