``The 04 series is a small portable gas monitor that can be worn by individuals.With its extensive sensor lineup and sturdy design, it can be used in a variety of industrial settings. ■Construction Compact and lightweight design that does not interfere with work even in narrow spaces. ■Gas plant The sturdy design can withstand a 7m drop test, making it safe for work at heights. ■Steel A newly developed CO sensor reduces the interference effect of hydrogen. ■Chemical plant Covers all kinds of applications with a rich lineup of toxic gas sensors. Equipped with a new high performance and durable R sensor ■Renewed sensor Excellent durability and performance, with a 3-year sensor warranty (OX-04G, SC-04 (NH3) and SC04 (CL2) have a 1-year sensor warranty). ■Suitable for a wide temperature range Can be used at -40 to 60℃ (depending on sensor specifications). ■Reduce hydrogen interference: CO-04 (C-) Developed a carbon monoxide sensor that is virtually unaffected by hydrogen interference. Compatible with environments where hydrogen coexists, such as in the steel market. ■Domestic manufacturer's first dual sensor: CX-04 Developed carbon monoxide and oxygen dual sensor and realized simultaneous detection and display of two components on a small portal. ・Sensor lineup includes 12 types in total In addition to general oxygen, carbon monoxide, and hydrogen sulfide, we also have a rich lineup of poisonous gases (SO2, NO2, HCN, PH3, NH3, CL2) Full functionality ■Achieves long continuous usage time of 9,000 hours Achieves a long continuous usage time of approximately 9,000 hours (OX-04G/CO-04/HS-04), which is the longest class of small portal gas monitors. ■Power supply specifications can be selected with dry batteries/rechargeable batteries Two power supply specifications are available: a dry battery specification that can be used immediately, and a rechargeable battery specification that can be used repeatedly (please specify when ordering). Safe design ■Cleared 7m fall endurance support Even if you drop it while working at heights, there is little risk of it breaking down, so you can use it with confidence. ■Dustproof and waterproof structure Protection grade: Equivalent to IP66/67, it has a dustproof and waterproof structure that is safe for outdoor work. ■Intrinsically safe explosion-proof structure Intrinsically safe explosion-proof construction (domestic explosion-proof/ATEX/IECEx/INMETRO) allows use in hazardous locations. *Other model numbers are available.

  • Product

    Personally worn gas detector 04 series
  • Usage Scenarios

    Chemical Industry Use / Architecture & Construction Use / Energy Industry Use

Share this product


480+ people viewing

Last viewed: 9 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

10 Models of Personally worn gas detector 04 series

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Accessories Alarm Alarm action Alarm reset operation Alarm setting value Buzzer volume CE marking Continuous use time Detection principle Detection range Display range Explosion-proof structure External dimensions/mass Function Gas to be detected JIS conformity standard Operating humidity range Operating temperature range Power supply Protection class Resolution Response time T90 Sampling method Various certifications
Personally worn gas detector 04 series-Part Number-OX-04G

OX-04G

Available upon quote Protective cover: 1 piece (Part number: 4123 6450 20)
Belt clip: 1 piece (Part number: 4123 6463 30)
AAA alkaline batteries: 2 (part number: 2757 0001 90)
Gas alarm: 3-stage alarm, STEL alarm, integration or TWA alarm, over alarm Failure alarm: Sensor connection/disconnection, battery voltage drop, calibration failure, clock abnormality, system abnormality Flashing lamp, intermittent buzzer, flashing gas concentration value, vibration Automatic return or self-retention L 18.0% LL 18.0% H 25.0% OVER 40.0% 80dB or more (30cm) ATEX Directive, EMC Directive, RoHS Directive Approximately 9,000 hours (dry battery) (Ni-MH battery) 6,000 hours Diaphragm galvanic battery type 0.0-25.0% 0.0-40.0% Intrinsically safe explosion-proof construction (dry battery specification) Explosion-proof construction electrical machinery and equipment type certification: Ex ia IIC T4 Ga ATEX: II1 G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding protrusions) / Approx. 93g Data logger, vibration, STEL alarm, integration or TWA alarm, one-touch calibration, peak value display, temperature display Oxygen JIS T 8201:2010 -20~+50℃ (no sudden changes) 10~90%RH (no condensation) 2 AAA alkaline batteries or 2 AAA Ni-MH batteries (Eneloop) IP66/68 equivalent 0.10% Within 20 seconds (Typical: 9 seconds) Diffusion type Type certification for explosion-proof electrical equipment, ATEX, IECEx, INMETRO
Personally worn gas detector 04 series-Part Number-OX-04

OX-04

Available upon quote Protective cover: 1 piece (Part number: 4123 6450 20) Belt clip: 1 piece (Part number: 4123 6463 30) AAA alkaline battery: 2 pieces (Part number: 2757 0001 90) Gas alarm: 3-stage alarm, STEL alarm, integration or TWA alarm, over alarm Failure alarm: Sensor connection/disconnection, battery voltage drop, calibration failure, clock abnormality, system abnormality Flashing lamp, intermittent buzzer, flashing gas concentration value, vibration Automatic return or self-retention L 18.0% LL 18.0% H 25.0% OVER 40.0% 80dB or more (30cm) ATEX Directive, EMC Directive, RoHS Directive Approximately 3,000 hours (dry battery) (Ni-MH battery) 2,000 hours Constant potential electrolysis type 0.0-25.0% 0.0-40.0% Intrinsically safe explosion-proof construction (dry battery specification) Explosion-proof construction electrical machinery and equipment type certification: Ex ia IIC T4 Ga ATEX: II1 G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding protrusions) / Approx. 93g Data logger, vibration, STEL alarm, integration or TWA alarm, one-touch calibration, peak value display, temperature display Oxygen It has the same performance as JIS compliant products. (We do not make a self-conformity declaration based on JIS O 1000.) -40~+60℃ (no sudden changes) 0~95%RH (no condensation) 2 AAA alkaline batteries or 2 AAA Ni-MH batteries (Eneloop) IP66/68 equivalent 0.10% Within 20 seconds (Typical: 8 seconds) Diffusion type Type certification for explosion-proof electrical equipment, ATEX, IECEx, INMETRO
Personally worn gas detector 04 series-Part Number-CO-04

CO-04

Available upon quote Protective cover: 1 piece (Part number: 4123 6450 20) Belt clip: 1 piece (Part number: 4123 6463 30) AAA alkaline battery: 2 pieces (Part number: 2757 0001 90) Gas alarm: 3-stage alarm, STEL alarm, integration or TWA alarm, over alarm Failure alarm: Sensor connection/disconnection, battery voltage drop, calibration failure, clock abnormality, system abnormality Flashing lamp, intermittent buzzer, flashing gas concentration value, vibration Automatic return or self-retention 1st 50ppm 2nd 150ppm 3rd 150ppm Total 150ppm STEL 200ppm OVER 2000ppm 80dB or more (30cm) ATEX Directive, EMC Directive, RoHS Directive Approximately 9,000 hours (dry battery) (Ni-MH battery) 6,000 hours Constant potential electrolysis type 0-500ppm 0-2000ppm Intrinsically safe explosion-proof construction (dry battery specification) Explosion-proof construction electrical machinery and equipment type certification: Ex ia IIC T4 Ga ATEX: II1 G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding protrusions) / Approx. 93g Data logger, vibration, STEL alarm, integration or TWA alarm, one-touch calibration, peak value display, temperature display Carbon monoxide - -40~+60℃ (no sudden changes) 0~95%RH (no condensation) 2 AAA alkaline batteries or 2 AAA Ni-MH batteries (Eneloop) IP66/68 equivalent 1ppm (0-300ppm) 10ppm (300-2000ppm) Within 30 seconds (Typical: 6 seconds) Diffusion type Type certification for explosion-proof electrical equipment, ATEX, IECEx, INMETRO
Personally worn gas detector 04 series-Part Number-CO-04 (C-)

CO-04 (C-)

Available upon quote Protective cover: 1 piece (Part number: 4123 6450 20) Belt clip: 1 piece (Part number: 4123 6463 30) AAA alkaline battery: 2 pieces (Part number: 2757 0001 90) Gas alarm: 3-stage alarm, STEL alarm, integration or TWA alarm, over alarm Failure alarm: Sensor connection/disconnection, battery voltage drop, calibration failure, clock abnormality, system abnormality Flashing lamp, intermittent buzzer, flashing gas concentration value, vibration Automatic return or self-retention 1st 50ppm 2nd 150ppm 3rd 150ppm Total 150ppm STEL 200ppm OVER 2000ppm 80dB or more (30cm) ATEX Directive, EMC Directive, RoHS Directive Approximately 6,200 hours (dry battery) (Ni-MH battery) 4,200 hours Constant potential electrolysis type 0-500ppm 0-2000ppm Intrinsically safe explosion-proof construction (dry battery specification) Explosion-proof construction electrical machinery and equipment type certification: Ex ia IIC T4 Ga ATEX: II1 G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding protrusions) / Approx. 93g Data logger, vibration, STEL alarm, integration or TWA alarm, one-touch calibration, peak value display, temperature display Carbon monoxide (hydrogen interference reduction) - -40~+60℃ (no sudden changes) 0~95%RH (no condensation) 2 AAA alkaline batteries or 2 AAA Ni-MH batteries (Eneloop) IP66/68 equivalent 1ppm (0-300ppm) 10ppm (300-2000ppm) Within 30 seconds (Typical: 17 seconds) Diffusion type Type certification for explosion-proof electrical equipment, ATEX, IECEx, INMETRO
Personally worn gas detector 04 series-Part Number-CX-04

CX-04

Available upon quote Protective cover: 1 piece (Part number: 4123 6450 20) Belt clip: 1 piece (Part number: 4123 6463 30) AAA alkaline battery: 2 pieces (Part number: 2757 0001 90) Gas alarm: 3-stage alarm, STEL alarm, integration or TWA alarm, over alarm Failure alarm: Sensor connection/disconnection, battery voltage drop, calibration failure, clock abnormality, system abnormality Flashing lamp, intermittent buzzer, flashing gas concentration value, vibration Automatic return or self-retention 1st 50ppm 2nd 150ppm 3rd 150ppm Total 150ppm STEL 200ppm OVER 2000ppm L 18.0% LL 18.0% H 25.0% 80dB or more (30cm) ATEX Directive, EMC Directive, RoHS Directive Approximately 4,600 hours (dry battery) (Ni-MH battery) 3,000 hours Constant potential electrolysis type 0-500ppm 0.0-25.0% 0-2000ppm 0.0-40.0% Intrinsically safe explosion-proof construction (dry battery specification) Explosion-proof construction electrical machinery and equipment type certification: Ex ia IIC T4 Ga ATEX: II1 G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding protrusions) / Approx. 93g Data logger, vibration, STEL alarm, integration or TWA alarm, one-touch calibration, peak value display, temperature display Carbon monoxide oxygen - -40~+60℃ (no sudden changes) 0~95%RH (no condensation) 2 AAA alkaline batteries or 2 AAA Ni-MH batteries (Eneloop) IP66/68 equivalent 1ppm (0-300ppm) 10ppm (300-2000ppm) 0.1% Within 30 seconds (Typical: 7 seconds) Within 30 seconds (Typical: 15 seconds) Diffusion type Type certification for explosion-proof electrical equipment, ATEX, IECEx, INMETRO
Personally worn gas detector 04 series-Part Number-HS-04

HS-04

Available upon quote Protective cover: 1 piece (Part number: 4123 6450 20) Belt clip: 1 piece (Part number: 4123 6463 30) AAA alkaline battery: 2 pieces (Part number: 2757 0001 90) Gas alarm: 3-stage alarm, STEL alarm, integration or TWA alarm, over alarm Failure alarm: Sensor connection/disconnection, battery voltage drop, calibration failure, clock abnormality, system abnormality Flashing lamp, intermittent buzzer, flashing gas concentration value, vibration Automatic return or self-retention 1st 1ppm 2nd 10ppm 3rd 10ppm TWA 1.0ppm STEL 5ppm OVER 200.0ppm 80dB or more (30cm) ATEX Directive, EMC Directive, RoHS Directive Approximately 9,000 hours (dry battery) (Ni-MH battery) 6,000 hours Constant potential electrolysis type 0.0-30.0ppm 0.0-200.0ppm Intrinsically safe explosion-proof construction (dry battery specification) Explosion-proof construction electrical machinery and equipment type certification: Ex ia IIC T4 Ga ATEX: II1 G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding protrusions) / Approx. 93g Data logger, vibration, STEL alarm, integration or TWA alarm, one-touch calibration, peak value display, temperature display Hydrogen sulfide JIS T 8205:2018 -40~+60℃ (no sudden changes) 0~95%RH (no condensation) 2 AAA alkaline batteries or 2 AAA Ni-MH batteries (Eneloop) IP66/68 equivalent 0.1ppm (0-30ppm) 1.0ppm (30-200ppm) Within 30 seconds (Typical: 18 seconds) Diffusion type Type certification for explosion-proof electrical equipment, ATEX, IECEx, INMETRO
Personally worn gas detector 04 series-Part Number-SC-04 (SO2)

SC-04 (SO2)

Available upon quote Protective cover: 1 piece (Part number: 4123 6450 20) Belt clip: 1 piece (Part number: 4123 6463 30) AAA alkaline battery: 2 pieces (Part number: 2757 0001 90) Gas alarm: 3-stage alarm, STEL alarm, integration or TWA alarm, over alarm Failure alarm: Sensor connection/disconnection, battery voltage drop, calibration failure, clock abnormality, system abnormality Flashing lamp, intermittent buzzer, flashing gas concentration value, vibration Automatic return or self-retention 1st 2.00ppm 2nd 5.00ppm 3rd 5.00ppm TWA 2.00ppm STEL 5.00ppm OVER 100.0ppm 80dB or more (30cm) ATEX Directive, EMC Directive, RoHS Directive Approximately 3,000 hours (dry battery) (Ni-MH battery) 2,000 hours Constant potential electrolysis type 0.0-20.0ppm 0.0-100.0ppm Intrinsically safe explosion-proof construction (dry battery specification) Explosion-proof construction electrical machinery and equipment type certification: Ex ia IIC T4 Ga ATEX: II1 G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding protrusions) / Approx. 93g Data logger, vibration, STEL alarm, integration or TWA alarm, one-touch calibration, peak value display, temperature display Sulfur dioxide - -40~+60℃ (no sudden changes) 0~95%RH (no condensation) 2 AAA alkaline batteries or 2 AAA Ni-MH batteries (Eneloop) IP66/68 equivalent 0.05ppm Within 30 seconds (Typical: 9 seconds) Diffusion type Type certification for explosion-proof electrical equipment, ATEX, IECEx, INMETRO
Personally worn gas detector 04 series-Part Number-SC-04 (NO2)

SC-04 (NO2)

Available upon quote Protective cover: 1 piece (Part number: 4123 6450 20) Belt clip: 1 piece (Part number: 4123 6463 30) AAA alkaline battery: 2 pieces (Part number: 2757 0001 90) Gas alarm: 3-stage alarm, STEL alarm, integration or TWA alarm, over alarm Failure alarm: Sensor connection/disconnection, battery voltage drop, calibration failure, clock abnormality, system abnormality Flashing lamp, intermittent buzzer, flashing gas concentration value, vibration Automatic return or self-retention 1st 3.00ppm 2nd 6.00ppm 3rd 6.00ppm TWA 3.00ppm STEL 5.00ppm OVER 20.0ppm 80dB or more (30cm) ATEX Directive, EMC Directive, RoHS Directive Approximately 3,000 hours (dry battery) (Ni-MH battery) 2,000 hours Constant potential electrolysis type 0.0-20.0ppm 0.0-20.0ppm Intrinsically safe explosion-proof construction (dry battery specification) Explosion-proof construction electrical machinery and equipment type certification: Ex ia IIC T4 Ga ATEX: II1 G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding protrusions) / Approx. 93g Data logger, vibration, STEL alarm, integration or TWA alarm, one-touch calibration, peak value display, temperature display Nitrogen dioxide - -40~+60℃ (no sudden changes) 0~95%RH (no condensation) 2 AAA alkaline batteries or 2 AAA Ni-MH batteries (Eneloop) IP66/68 equivalent 0.05ppm Within 30 seconds (Typical: 6 seconds) Diffusion type Type certification for explosion-proof electrical equipment, ATEX, IECEx, INMETRO
Personally worn gas detector 04 series-Part Number-SC-04 (HCN)

SC-04 (HCN)

Available upon quote Protective cover: 1 piece (Part number: 4123 6450 20) Belt clip: 1 piece (Part number: 4123 6463 30) AAA alkaline battery: 2 pieces (Part number: 2757 0001 90) Gas alarm: 3-stage alarm, STEL alarm, integration or TWA alarm, over alarm Failure alarm: Sensor connection/disconnection, battery voltage drop, calibration failure, clock abnormality, system abnormality Flashing lamp, intermittent buzzer, flashing gas concentration value, vibration Automatic return or self-retention 1st 4.7ppm 2nd 9.4ppm 3rd 9.4ppm TWA 0.9ppm STEL 4.5ppm OVER 30.0ppm 80dB or more (30cm) ATEX Directive, EMC Directive, RoHS Directive Approximately 3,000 hours (dry battery) (Ni-MH battery) 2,000 hours Constant potential electrolysis type 0.0-20.0ppm 0.0-30.0ppm Intrinsically safe explosion-proof construction (dry battery specification) Explosion-proof construction electrical machinery and equipment type certification: Ex ia IIC T4 Ga ATEX: II1 G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding protrusions) / Approx. 93g Data logger, vibration, STEL alarm, integration or TWA alarm, one-touch calibration, peak value display, temperature display Hydrogen cyanide - -20~+60℃ (no sudden changes) 0~95%RH (no condensation) 2 AAA alkaline batteries or 2 AAA Ni-MH batteries (Eneloop) IP66/68 equivalent 0.1ppm Within 90 seconds (Typical: 36 seconds) Diffusion type Type certification for explosion-proof electrical equipment, ATEX, IECEx, INMETRO
Personally worn gas detector 04 series-Part Number-SC-04 (PH3)

SC-04 (PH3)

Available upon quote Protective cover: 1 piece (Part number: 4123 6450 20) Belt clip: 1 piece (Part number: 4123 6463 30) AAA alkaline battery: 2 pieces (Part number: 2757 0001 90) Gas alarm: 3-stage alarm, STEL alarm, integration or TWA alarm, over alarm Failure alarm: Sensor connection/disconnection, battery voltage drop, calibration failure, clock abnormality, system abnormality Flashing lamp, intermittent buzzer, flashing gas concentration value, vibration Automatic return or self-retention 1st 0.30ppm 2nd 0.60ppm 3rd 0.60ppm TWA 0.30ppm STEL 1.00ppm OVER 20.0ppm 80dB or more (30cm) ATEX Directive, EMC Directive, RoHS Directive Approximately 3,000 hours (dry battery) (Ni-MH battery) 2,000 hours Constant potential electrolysis type 0.0-30.0ppm 0.0-20.0ppm Intrinsically safe explosion-proof construction (dry battery specification) Explosion-proof construction electrical machinery and equipment type certification: Ex ia IIC T4 Ga ATEX: II1 G Ex ia IIC T4 Ga IECEx: Ex ia IIC T4 Ga Approx. 54 (W) x 67 (H) x 24 (D) mm (excluding protrusions) / Approx. 93g Data logger, vibration, STEL alarm, integration or TWA alarm, one-touch calibration, peak value display, temperature display Phosphine - -40~+60℃ (no sudden changes) 0~95%RH (no condensation) 2 AAA alkaline batteries or 2 AAA Ni-MH batteries (Eneloop) IP66/68 equivalent 0.1ppm Within 30 seconds (Typical: 6 seconds) Diffusion type Type certification for explosion-proof electrical equipment, ATEX, IECEx, INMETRO

Click on the part number for more information about each product