Portable gas detector GX-6000 series-GX-6000
Portable gas detector GX-6000 series-Riken Keiki Co., Ltd.

Portable gas detector GX-6000 series
Riken Keiki Co., Ltd.

🧪 Chemical Industry Use ⚡ Energy Industry Use

About This Product

A first for a domestic manufacturer that can detect up to six types of gas simultaneously with one device. VOC detection is also possible with the photo ionization sensor (PID). Features ■Can detect up to 6 types of gases One unit can simultaneously detect up to six types of gases, including flammable gases, oxygen, hydrogen sulfide, carbon monoxide, other toxic gases, and volatile organic solvent gases (VOCs). ■ Voluntary management of harmful chemical substances Ideal for safety management of chemical substances subject to mandatory risk assessment. A single device can measure several types of gas, which is effective in increasing work efficiency. ■Can be displayed in Japanese It can be displayed in multiple languages ​​including Japanese, and operations such as changing settings can be easily performed. The full dot display makes it easy to see both letters and numbers. ■Panic alarm & man-down alarm Panic alarm: A function that manually issues an alarm to notify the surrounding area of ​​an abnormality at the site. Man-down alarm: A function that automatically issues an alarm if no movement is detected for a certain period of time, informing those around you of the wearer's abnormality. Even easier to use and smarter ■Full dot display The full-dot display now enables clearer and more diverse displays than conventional segment displays. ■Multilingual display Japanese/English display possible Other languages ​​also supported ■Panic alarm function The panic alarm function is a function that allows the wearer to manually sound an alarm in the event of a problem, in order to call for help from those around them or to notify them of an abnormality. ■Man-down alarm function ・GX-6000 is equipped with a motion sensor to detect movement. ・Man-down alarm is a function that automatically issues an alarm if the motion sensor does not detect any movement for a certain period of time, alerting those around you that the wearer is abnormal. ■Flip the top and bottom of the screen according to your movements Automatically flips the screen 180 degrees according to your movements. It is an ON/OFF switching type and can also be fixed. ■With LED light to illuminate the front You can feel safe even in dark places by turning on the LED light. The LED light can be easily turned on by pressing and holding the button. The screen is also backlit, increasing work efficiency in dark places.

  • Product

    Portable gas detector GX-6000 series
  • Usage Scenarios

    Chemical Industry Use / Energy Industry Use

Share this product


190+ people viewing

Last viewed: 15 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Portable gas detector GX-6000 series

Product Image Part Number Price (excluding tax) Accessories Alarm display Alarm type Buzzer volume Continuous use time Display Display language Explosion-proof grade Explosion-proof structure External dimensions Function Mass Operating humidity range Operating temperature range Power supply Protection class Sampling method Suction flow rate Various certifications
Portable gas detector GX-6000 series-Part Number-GX-6000

GX-6000

Available upon quote Lithium ion battery unit & charger or dry cell unit & 3 single alkaline batteries
protect cover
belt clip
tapered nozzle
strap
Protective film (for LCD screen)
Various filters
Gas alarm: Lamp flashing, buzzer continuously modulating sound, gas concentration display and alarm content flashing, vibration Malfunction alarm: lamp flashing, buzzer intermittent, fault content display Others: Lamp flashing, buzzer continuously modulating sounding Gas alarm: 2-stage alarm, TWA, STEL, OVER alarm Failure alarm: System abnormality, sensor abnormality, low battery voltage, poor calibration, low flow rate Others: Panic alarm, man-down alarm 95dB (A) or more at 30cm (with protective cover attached) Lithium ion battery unit: Approximately 14 hours (25℃, fully charged, no alarm, no lighting) Dry battery unit: Approximately 8 hours (25℃, new dry battery, no alarm, no lighting) LCD digital (full dot display) Japanese/English/French/Spanish/Portuguese/German/Italian/Russian/Korean Ex ia IIC T4X (Type approval for explosion-proof electrical equipment) /Ex ia IIC/IIB T4/T3 Ga (ATEX) /II 1G Ex ia IIC/IIB T4/T3 Ga (IECEx) Intrinsically safe explosion-proof structure Approximately 70 (W) × 201 (H) × 54 (D) mm (excluding protrusions) LCD backlight, data logger, peak value display, log data display, multilingual display, reverse screen display, LED light Approx. 500g (when using lithium ion battery unit) / Approx. 450g (when using dry battery unit) 95%RH or less (no condensation) -20~+50℃ (no sudden changes) Lithium ion battery unit or dry battery unit <3 AA alkaline batteries> IP67 equivalent Pump suction type 0.45L/min or more (open flow rate) Explosion-proof construction electrical equipment type approval passed product, ATEX explosion-proof inspection passed product, IECEx passed product, JG type approval passed product, CE Marking