Product Image | Part Number | Price (excluding tax) | Efficiency (typical value) | Electric shock protection | Frequency (typical value) | Frequency range | Holdup time (typical) | IEC safety class | Impulse current (typical value) | Input current (max) | Leakage current (typical value) | Line regulation | Load regulation | MTBF | Maximum capacitive load | Medical safety | Operating temperature | Output current | Output voltage | Overcurrent | Overvoltage | Power derating | Rated power (maximum) | Ripple & Noise | Short circuit | Soldering temperature | Standby power consumption | Storage humidity (maximum) | Storage temperature | Temperature counting | Voltage range | Voltage tolerance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ADM360K240S001A |
Available upon quote | 90% | 2 x MOPP @ primary to secondary | 65kHz | 50~60Hz |
15ms @ 115VAC 80ms @ 230VAC |
Class II | 10A@115VAC, 23A@230VAC | 0.7A@115VAC, 0.5A@230VAC | 0.1mA @ 264VAC, 60Hz | ±0.5% at full load | ±1% | ≥300,000H @ 25℃ | 2,000uF | EN60601-1 | -40~+70℃ | 1,500mA | DC24V | ≥130%IO automatic recovery | ≤27VDC @ 12V output, ≤40VDC @ 24V output |
2.7%/℃ @ -40 ~ -25℃ 2.4%/℃ @ +50 ~ +70℃, 12VDC 2.7%/℃ @ +55 ~ +70℃ |
36W | 50mV (typical), 100mV (max) @20MHz | Long-term short circuit, automatic recovery. |
260±5℃ @ wave soldering, 5~10 seconds 360±10℃ @ manual soldering, 3-5 seconds |
0.075W | 95%RH (max) | -40~+85℃ | ±0.02%/℃ | AC100~240V | ±5% | |
ADM450K150S001A |
Available upon quote | 88% | 2 x MOPP @ primary to secondary | 65kHz | 47~63Hz |
15ms @ 100VAC 80ms @ 240VAC |
Class II | 30A@100VAC, 40A@240VAC | 1.1A@100VAC, 0.9A@240VAC | 0.1mA @ 264VAC, 60Hz | ±3% at full load | ±3% | ≥300,000H @ 25℃ | 7,000uF | EN60601-1 | -40~+70℃ | 3,000mA | DC15V | ≥140%IO automatic recovery | ≤23VDC @ 15V output |
3.6%/℃ @ -40 ~ -25℃ 2.4%/℃ @ +50 ~ +70℃, 15VDC 2.7%/℃ @ +55 ~ +70℃ |
45W | 90mV (typical), 150mV (max) @20MHz | Long-term short circuit, automatic recovery. |
260±5℃ @ wave soldering, 5~10 seconds 360±10℃ @ manual soldering, 3-5 seconds |
0.1W | 95%RH (max) | -40~+85℃ | ±0.02%/℃ | AC100~240V, DC100~370V | ±5% | |
ADM360K120S001A |
Available upon quote | 89% | 2 x MOPP @ primary to secondary | 65kHz | 50~60Hz |
15ms @ 115VAC 80ms @ 230VAC |
Class II | 10A@115VAC, 23A@230VAC | 0.7A@115VAC, 0.5A@230VAC | 0.1mA @ 264VAC, 60Hz | ±0.5% at full load | ±1% | ≥300,000H @ 25℃ | 5,000uF | EN60601-1 | -40~+70℃ | 3,000mA | DC12V | ≥130%IO automatic recovery | ≤27VDC @ 12V output, ≤40VDC @ 24V output |
2.7%/℃ @ -40 ~ -25℃ 2.4%/℃ @ +50 ~ +70℃, 12VDC 2.7%/℃ @ +55 ~ +70℃ |
36W | 50mV (typical), 100mV (max) @20MHz | Long-term short circuit, automatic recovery. |
260±5℃ @ wave soldering, 5~10 seconds 360±10℃ @ manual soldering, 3-5 seconds |
0.075W | 95%RH (max) | -40~+85℃ | ±0.02%/℃ | AC100~240V | ±5% |