SPD (Thunder Defense Product) LAN Thunder Guard Series that protects LAN from lightningHandling Company
NISSHIN ELECTRIC CO.,LTDCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Operating environment | Signal Part (LINE) Rated current | Power supply part (Power) rated current | Signal Part (LINE) Transmission loss | Applicable line | Signal Part (LINE) Voltage protection level | Power supply part (Power) Voltage protection level | Power supply part (Power) Maximum continuous voltage | Signal Part (LINE) Maximum continuous voltage | Poe | Port configuration | Transmission characteristics | Impulse durability | Main accessories | Used line distance | ROHS2 Directive | mass | External dimensions | Impulse -resistant voltage | Voltage protection level | power consumption | Surge clamp voltage | power supply | Rated voltage | Test class / discharge current IMAX | Insulation resistance | cable length |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
NPL-4002 |
Available upon quote |
-10 ° C ~+50 ℃ Humidity 15-85 % (without condensation) |
0.5A |
1.5A |
1.8db or less (DC ~ 500MHz) |
10GBASE-T, 1,000BASE-T, 100BASE-TX, 10BASE-T |
60V or less (between lines), 700V or less (between ground) |
90V or less (between lines), 700V or less (between ground) |
DC58V |
DC8.5V |
IEEE802.3BT (PoE ++), IEEE802.3AT (PoE+), IEEE802.3AF (PoE) compatible DC58V 1.5A |
RJ45 port x 2 |
Compatible with category 6A |
Category C2: 8/20μs 10ka category D1: 10/350μs 2kA |
Fixed metal fittings x 1, ground pressed terminal (used line diameter 2 ~ 3.5SQ) x 3, cropping terminal for ground branching * with tube (used wire diameter 2SQ) x 1 piece, DIN rail mounting part (35mm) For DIN rails, others |
Up to 100m. Depending on the condition of the connected device or line, the maximum distance that can be communicated may be shorter. |
correspondence |
Approximately 135g |
Approximately 25 mm (W) x 47 mm (H) x 90 mm (d) (excluding protrusion) |
- | - | - | - | - | - | - | - | - | |
NPL-2002 |
Available upon quote |
-10 ° C ~+50 ℃ Humidity 35-85 % (without condensation) |
- | - | - |
1,000BASE-T, 100BASE-TX, 10BASE-T |
- | - | - | - |
IEEE802.3BT (PoE ++), IEEE802.3AT (PoE Plus) compliant, DC60V 600MA |
RJ45 port x 2 |
Compatible with category 5E |
Category C2: 8/20μs 5kA (10 times) Category D1: 10/350 μS 2.5kA (2 times) |
GND connection line (line from 1.25SQ IV) Approximately 0.5m x 1, GND connection line (line from 1.25SQ IV) about 50mm x 1, others |
Up to 100m. Depending on the condition of the connected device or line, the maximum distance that can be communicated may be shorter. |
correspondence |
Approximately 60g |
Approximately 40 mm (W) x 23 mm (H) x 82 mm (d) (excluding protrusion) |
- | - | - | - | - | - | - | - | - | |
NPL-1001 |
Available upon quote |
-20 ° C ~+60 ℃ Humidity 35-85 % (without condensation) |
- | - | - |
1,000BASE-T, 100BASE-TX, 10BASE-T |
- | - | - | - | - |
RJ45 port x 2 |
Compatible with category 5E |
- |
none |
Up to 100m. Depending on the condition of the connected device or line, the maximum distance that can be communicated may be shorter. |
correspondence |
Approximately 20g |
Approximately 24 mm (W) x 22 mm (H) x 51 mm (d) (excluding protrusion) |
10kV on the cable side and the device side 10/700μs or 1.2/50 μs |
- | - | - | - | - | - | - | - | |
NPL-2001 |
Available upon quote |
-10 ° C ~+50 ℃ Humidity 35-85 % (without condensation) |
- | - | - |
1,000BASE-T, 100BASE-TX, 10BASE-T |
- | - | - | - | - |
RJ45 port x 2 |
Compatible with category 5E |
Category C2: 8/20μs 5kA (10 times) Category D1: 10/350 μS 2.5kA (2 times) |
GND connection line (line from 1.25SQ IV) Approximately 0.5m x 1, GND connection line (line from 1.25SQ IV) about 50mm x 1, others |
Up to 100m. Depending on the condition of the connected device or line, the maximum distance that can be communicated may be shorter. |
correspondence |
Approximately 60g |
Approximately 40 mm (W) x 23 mm (H) x 82 mm (d) (excluding protrusion) |
- |
Voltage protection level: 500V or less |
- | - | - | - | - | - | - | |
NPL-3001 |
Available upon quote |
-10 ° C ~+50 ℃ Humidity 35-85 % (without condensation) |
- | - | - | - | - | - | - | - | - | - | - | - |
GND connection line (line from 1.25SQ IV) Approximately 0.5m x 1, GND connection line (line from 1.25SQ IV) about 50mm x 1, others |
- |
correspondence |
Approximately 100g (including code) |
Approximately 40 mm (W) x 23 mm (H) x 82 mm (d) (excluding protrusion) |
- | - |
0.5W or less (LED for operation confirmation only) |
(1) Power line -G terminal between terminals: 1,500V or less (combination waveform 4KV) (2) Power lines: 1,500V or less (at combination waveform 4KV) |
AC100V 50/60Hz |
AC125V 50/60Hz |
Class II / 5kA (between ground) |
Power line -G.G terminal DC500V 50mΩ or more |
About 1m (excluding connector) |