Various tests for tests, which are indispensable for product development and scale -up data, are available. You can choose from 3L, 5L, 7L. You can select two types from 3,5,7L and make a combination type. ■ Features ・ Because it has a structure similar to a production machine, you can get the optimal scale up data for production. ・ With a built -in vacuum pump, it is easy to perform emulsification and stirring tests and foam under reduced pressure. ・ Various replacement feathers can be easily replaced, and various stirring tests can be performed. (High viscosity homo mixer/low -viscosity homo mixer/disposal mixer/ultramixxer) ・ The overall height is low, and it can be easily operated, such as input of raw materials. ・ Because the stirring tank is easy to remove, it can be washed with a sink (sink). ・ The temperature control of the heated water tank is possible ・ It is also possible to make 3L-5L combined device and 3L-7L combined device. (By replacing the glass container and the stirring blades) ・ The stirring tank and the jacket are made of enhanced glass, and it is possible to work while checking the stirring state. -The liquid portion is made of glass and stainless steel, has excellent touch resistance and is hygienic. ・ You can freely change the rotation speed of homo mixer and scratching mixer, and you can know the accurate rotation speed with the digital speedometer. -The switching valve can easily heat and cool the product in the emulsifier tank. ・ Disassembly and assembly of the glid part can be easily cleaned. ・ The stirring tank can be rolled over by operating the lever to easily extract the product. ■ Use ・ Cosmetics: Cosmetic cream, lotion, lotion, shampoo -rinse, gel product, toothpaste, hair color ・ Pharmaceuticals: ointment ・ Food: Cream products, mayonnaise, dressing ・ Chemicals: Silicone oil, wax, metal paste

  • Product

    Acquisition of optimal scale updata with a structure close to a production machine PVQ-A for tests PVQ-A

Share this product


490+ people viewing

Last viewed: 1 hour ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

6 Models of Acquisition of optimal scale updata with a structure close to a production machine PVQ-A for tests PVQ-A

Items marked with have different values depending on the model number.

Click on the part number for more information about each product

Product Image Part Number Price (excluding tax) Cosmetic (L) Director Mixer Motor (KW) Equipment dimensions (mm) Equipment weight (kg) Homo Mixer Motor (KW) Homomixer rotation speed (min-1) Power (V) Scattering mixer rotation speed (min-1) Standard preparation amount (L) accessories option
Acquisition of optimal scale updata with a structure close to a production machine PVQ-A for tests PVQ-A-Part Number-PVQ-A-1UN

PVQ-A-1UN

Available upon quote 1 0.2 828 (W) x 1,030 (L) x 1,568 (H) 246 0.45 1,000-10,000 AC100 25 ~ 250 0.7 Vacuum pump, heated water tank (temperature control possible) P.I.T. Kencer (electrical conduction rate) can be attached
Acquisition of optimal scale updata with a structure close to a production machine PVQ-A for tests PVQ-A-Part Number-PVQ-A-3UN

PVQ-A-3UN

Available upon quote 3 0.2 828 (W) x 1,030 (L) x 1,568 (H) 246 0.45 1,000-10,000 AC100 25 ~ 250 2 Vacuum pump, heated water tank (temperature control possible) P.I.T. Kencer (electrical conduction rate) can be attached
Acquisition of optimal scale updata with a structure close to a production machine PVQ-A for tests PVQ-A-Part Number-PVQ-A-5UN

PVQ-A-5UN

Available upon quote Five 0.2 828 (W) x 1,030 (L) x 1,568 (H) 246 0.45 1,000-10,000 AC100 25 ~ 250 3.5 Vacuum pump, heated water tank (temperature control possible) P.I.T. Kencer (electrical conduction rate) can be attached
Acquisition of optimal scale updata with a structure close to a production machine PVQ-A for tests PVQ-A-Part Number-PVQ-A-7UN

PVQ-A-7UN

Available upon quote 7 0.2 828 (W) x 1,030 (L) x 1,568 (H) 246 0.45 1,000-10,000 AC100 25 ~ 250 Five Vacuum pump, heated water tank (temperature control possible) P.I.T. Kencer (electrical conduction rate) can be attached
Acquisition of optimal scale updata with a structure close to a production machine PVQ-A for tests PVQ-A-Part Number-PVQ-A-3/5UN

PVQ-A-3/5UN

Available upon quote 3/5 0.2 828 (W) x 1,030 (L) x 1,568 (H) 246 0.45 1,000-10,000 AC100 25 ~ 250 2/3.5 Vacuum pump, heated water tank (temperature control possible) P.I.T. Kencer (electrical conduction rate) can be attached
Acquisition of optimal scale updata with a structure close to a production machine PVQ-A for tests PVQ-A-Part Number-PVQ-A-3/7UN

PVQ-A-3/7UN

Available upon quote 3/7 0.2 828 (W) x 1,030 (L) x 1,568 (H) 246 0.45 1,000-10,000 AC100 25 ~ 250 2/5 Vacuum pump, heated water tank (temperature control possible) P.I.T. Kencer (electrical conduction rate) can be attached

Click on the part number for more information about each product

Customers who viewed this product also viewed

Other products of Mizuho Kogyo Co., Ltd.


View more products of Mizuho Kogyo Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree