All Categories
History
Response Rate
100.0%
Response Time
1.2hours
Very Fast Response
Product
Easy measurement with wireless function wireless logger L-LOG series/sensorHandling Company
Logical product Co., Ltd.Categories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Aerial line power | Measurement range | Measurement accuracy | Measurement resolution | Sampling frequency | Operating temperature | Wireless frequency | Wireless system | Strain gauge resistance value | Hearm gauge connection method | Measurement CH | Memory capacity | External dimensions | Continuous measurement time | Interval measurement | Sensor connection portion | Power saving function | Wireless communication distance | power supply | Synchronous delay | Maximum number of connections | Frequency response range | thermocouple | weight | Low -pass filter | Sensor power supply supply | Other functions | Acceleration sensor |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
LP-LWS200SG |
Available upon quote |
+5dbm or less |
± 20,000 μst |
Within ± 20μst (after 5Hz LPF processing for data that measured+2,000 μst distortion) |
± 5 μst or less |
0.01, 0.1, 1, 5, 10, 10, 50, 50, 200, 500, 1,000Hz |
0 to 40 ° C (without condensation) |
2,405MHz ~ 2,480MHz, 5MHz interval, 16 waves |
2.4GHz band specified small power (IEEE802.15.4 compliant/proprietary protocol) |
350Ω, 120Ω |
3 -wire/2 -wire type (1 gauge, 2 gauge (vs. side/neighbor), 4 gauge) |
4ch (connected at the screwless terminal stand) |
512MB |
70.4 x 50.4 x 33.2mm, non -waterproof (including fixing flange and sensor connection) |
When using two CR-123A: Approximately 0.19 (at 1Hz sampling), when two TL-5930 are used: 1 year or more (at 1Hz sampling) |
Interval measurement is possible (△ Hz sampling is repeated every hour) |
Screwless type terminal stand |
It has a sleep function (power saving function when waiting) |
View 50m (depending on the mounting state of this unit and the surrounding environment) |
Supply 5V from battery (2 CR-123A or 2 TL-5930) or USB (battery is recommended for noise measures at the time of measurement) |
- | - | - | - | - | - | - | - | - | |
LP-LWS200TC |
Available upon quote |
+5dbm or less |
Each thermal electrician, K type: -200 ~ 1,200 ° C, T type: -200 ~ 350 ° C, E type: -200 ~ 800 ° C, J type: -200 ~ 750 ° C, r type: 0 to 1,600 ° C, N type: -200 ~ 1,250 ° C |
Within ± 2 ° C (specified by calibrator measurement, does not include thermal electricity vs.) |
± 0.05 ℃ |
0.01, 0.1, 1, 5, 10Hz |
0 to 40 ° C |
2,405MHz ~ 2,480MHz, 5MHz interval, 16 waves |
2.4GHz band specified small power (IEEE802.15.4 compliant/proprietary protocol) |
- | - |
4ch (connected at the screwless terminal stand) |
External microSD memory (up to 32GB) |
50.4 x 70.4 x 33mm, non-waterproof (including fixing flanges and sensor connections), battery Box CR123A 2: 63 x 42 x 24mm, battery Box TL-5930 2: 90 x 75 x 32mm |
When using 2 CR-123A: About 50 hours (10Hz sampling continuous measurement), when two TL-5930 are used: TBD time (10Hz sampling) |
Interval measurement is possible (repeated in △ per minute every time) |
- |
It has a sleep function (power saving function when waiting) |
View 50m (depending on the mounting state of this unit and the surrounding environment) |
Supply 5V from battery (2 CR-123A or 2 TL-5930) or USB (battery is recommended for noise measures at the time of measurement) |
± 1 Sample time (for sample frequency 10Hz <± 100ms) |
25 units |
2Hz ~ 10kHz (within ± 0.5db) |
Measured by K/ T type/ E/ E/ J type/ R type/ N type (rose line connection) |
Approximately 50g |
- | - | - | - | |
LP-LWS200PA |
Available upon quote |
+5dbm or less |
Maximum input voltage: Switch to ± 10V/± 5V/± 2V/± 1V |
Within ± 5 % (± 0.5dB) in each range (provisional specification) |
± 15bit resolution (total 16bit) in each range fluorine |
Up to 20kHz (/10kHz/2kHz/1kHz/200Hz/100Hz/50Hz/10Hz), synchronization accuracy should be within each sampling time (± 50US at 20kHz) |
0 to 40 ° C (without condensation) |
2,405MHz ~ 2,480MHz, 5MHz interval, 16 waves |
2.4GHz band specified small power (IEEE802.15.4 compliant/proprietary protocol) |
- | - |
4ch (connected with a standard BNC connector) |
External microSD memory (up to 32GB) |
100 × 150 × 45mm (non -waterproof, connector, SW, etc. are not included) |
When using two CR-123A: about 10 hours (during continuous measurement 20kHz sampling) |
Interval measurement is possible (repeated in △ per minute every time) |
- | - |
View 50m (depending on the mounting state of this unit and the surrounding environment) |
Supply 5V from battery (2 CR-123A) or USB (battery is recommended for noise measures when measuring) |
- | - |
2Hz ~ 10kHz (within ± 0.5db) |
- | - |
10kHz/5kHz/1kHz/500Hz/100Hz/OFF (through) Switch the secondary Vessel analog filter (-12db/Oct) |
24V 2ma (± 5%) |
CH operation display: Displays the operation status of each CH in LED |
Built -in amplifier -type acceleration sensor (compatible with 24V 2MA constant current power supply) |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
1.2hrs