All Categories

History

Simulation of multi-air conditioner for buildings Enepro21 Multi-Enepro21 Multi
Simulation of multi-air conditioner for buildings Enepro21 Multi-E.I.Engineering Co.,Ltd

Simulation of multi-air conditioner for buildings Enepro21 Multi
E.I.Engineering Co.,Ltd


About This Product

■Enepro21Multi Multi-air conditioner simulation for buildings

We have developed software that can accurately simulate the energy consumption, system COP, CO2 emissions, and operating costs of a multi-air conditioner system for buildings in the same way as Enepro21 Regular. Features of Enepro21 Multi

■ About simulation calculations

- A division that includes heat load and multiple air conditioning systems (outdoor unit + indoor unit) corresponding to it is called a "block", and energy and cost calculations can be performed on a block basis. - Even for tenant buildings and complex buildings that contain multiple facilities, the system can be accurately evaluated by dividing them into blocks. - If the heat load of the entire building is known and it is not possible to separate the heat load for each facility, the whole can be treated as one block and processed.

■Setting the heat load and pattern

- It is assumed that the cooling load and heating load have been created. The heat load to be set is a 24-hour value "averaged" by month and pattern, for example, in an office, it is set in two patterns, weekdays and holidays. - It is also possible to set a 365-day load pattern like a restaurant. ・The load pattern can be set arbitrarily for each block according to the characteristics of each block.

■Enepro21 Multi Utilization Data Collection can be used

・For ease of use, the following data is published on a dedicated website, just like Enepro21Regular ・Equipment data: Outdoor unit performance data and indoor unit performance data are prepared ・Environmental load data ・Electricity rate data ・Gas rate data ・Temperature data*・Performance data for outdoor units (EHP, GHP) includes partial load characteristics, outdoor temperature characteristics, etc.

■Fine-grained settings can be made

・Easily correct capacity corrections due to the equivalent length of refrigerant piping and the difference in height between indoor and outdoor air using internal data ・Set heat loss in refrigerant piping ・Evaluate the effect of water sprinkling on the outdoor unit ・Correct the suction temperature of the outdoor unit, taking into account the circulation of exhaust gas from the indoor unit ・Set the aging deterioration of the COP of the outdoor unit ・Finely set the operating status of the indoor unit ・All output reports can be exported as Excel files, and output graphs can be exported as image files (JPG).

  • Product

    Simulation of multi-air conditioner for buildings Enepro21 Multi

Share this product


20+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.