Product
Steam boiler Latent heat recovery once-through boiler ComboGas seriesHandling Company
Hirakawa Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | LPG (m3N/h) | LPG boiler efficiency | Boiler type | Heat transfer area (m2) | Power supply used (50/60Hz) | Handler qualification | Safety valve outlet | Normal working pressure (MPa) | Water capacity during regular use (ℓ) | Required power (kW) | Exhaust gas outlet | Drainage outlet | Converted evaporation amount (kg/h) | Maximum working pressure (MPa) | Water capacity when full (ℓ) | Thermal power (kW) | Fuel supply pressure (kPa) | Fuel inlet | Combustion control method | Water supply inlet | Steam outlet | Product dry weight (kg) | City gas 13A (m3N/h) | City gas 13A boiler efficiency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CG-1500 |
Available upon quote |
36.7 |
102 |
Small boiler |
8.42 |
AC200V 3 phase |
Attendance at “special education” provided by business owner or above |
40 |
0.49 or more |
200 |
8.7 |
300 |
Twenty five |
1,500 |
0.98 |
380 |
940 |
98.1~294 (medium pressure B) |
40 |
Proportional combustion |
Twenty five |
65 |
3,200 |
81.7 |
102 |