All Categories
History
Product
FA device, laser marker/welding machine Static electricity countermeasure equipment (ionizer) Fan type ionizer ER-FHandling Company
Panasonic Industry Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Earthing method | Ion balance | Ozone generation amount | Main features | Operating ambient temperature | Ambient humidity | Discharge output voltage | Discharge method | Material | Current consumption | Indicator light | Mass | Compliance regulations | Static neutralization time (±1,000V→±100V) | Power supply voltage | Accessories |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
ER-F12A |
Available upon quote |
C (capacitor) ground |
±10V or less |
0.04ppm or less |
Error output, discharge stop input |
0~+50℃ (no condensation), -10~+65℃ during storage |
35~65% RH (no condensation), 35~65% RH during storage |
±about 2kV |
High frequency AC method |
Case: ABS, Louver: ABS, Discharge needle unit: PBT, |
700mA or less |
Discharge error (red), fan error (red), power supply (green), discharge (green) |
Body mass: Approx. 790g |
CE marking (EMC directive, RoHS directive), UKCA marking (EMC regulation, RoHS regulation) |
Approximately 1 second |
24V DC ±10% |
Straight louver: 1 piece, wide-angle louver: 1 piece, |