All Categories
History
Product
Relay/Coupler Power Relay (Over 2A) DK RelayHandling Company
Panasonic Industry Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Coil rated voltage | Coil resistance (±10%) (at 20℃) | Protective structure | Operating time (initial) (at 20℃) | Operating function | Rated excitation current (±10%) (at 20℃) | Rated power consumption | Recovery time (initial) (at 20℃) | Touching voltage (at20℃) | Contact capacity (resistive load) | Contact shape | Maximum allowable contact power (resistive load) | Maximum allowable contact voltage | Maximum allowable contact current | Contact material | Contact configuration | Contact resistance (initial) | Maximum applied voltage (at20℃) | Minimum applicable load (reference value) | Terminal shape | Quantity in box Inner box (pieces) | Quantity in box Outer box (pieces) | Insulation resistance (initial) | Surge withstand voltage (initial): between contact and coil | Withstand voltage (initial): between contact and coil | Withstand voltage (initial): Between contacts | Malfunction shock | Open circuit voltage (at20℃) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
AW3011F |
Available upon quote |
3V DC |
45Ω |
Plastic seal |
10 ms or less at coil rated voltage (not including contact bounce) |
Single stable type |
66.6mA |
200mW |
8 ms or less at coil rated voltage (excluding contact bounce, no diode) |
70% V or less of coil rated voltage (initial) |
10A 250V AC, 10A 30V DC |
Single |
2,500 VA (AC), 300 W (DC) |
250V AC, 125V DC (0.2A) |
10A (AC, DC) |
Au flash on AgSnO2 system |
1a |
30 mΩ or less (6 V DC 1 A voltage drop method) |
130% V of coil rated voltage |
10mA 5V DC |
Printed board terminal |
50 |
500 |
1,000 MΩ or more (measured using a 500 V DC insulation resistance tester at the same location as in the withstand voltage section) |
10,000V |
4,000 V AC for 1 minute (detection current: 10 mA) |
1,000 V AC for 1 minute (detection current: 10 mA) |
98 m/s2 (half-sine pulse: 11 ms, detection time: 10 μs) |
10% V or more of coil rated voltage (initial) |
Reviews shown here are reviews of companies.