FA Sensor Proximity Sensor Square Proximity Sensor [Built-in Amplifier] GX-F/HHandling Company
Panasonic Industry Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Cable | Cable extension | Output | Operation indicator light | Stable detection range | Hysteresis (hysteresis) | Maximum operating distance | Maximum response frequency | Body mass | Material | Sensing distance variation Temperature characteristics | Variation in detection distance Voltage characteristics | Standard detection object | Current consumption | Repeatability | Environmental resistance Operating ambient temperature | Environmental resistance Ambient humidity | Environmental resistance Protective structure | Environmental resistance Insulation resistance | Environmental resistance Vibration resistance | Environmental resistance Impact resistance | Environmental resistance Voltage resistance | Compliance regulations and certifications | Power supply voltage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
GX-F6A (I) |
Available upon quote |
0.15mm2 3-core oil-resistant, heat-resistant, cold-resistant cabtire cable with 1m |
Can be extended to a total length of 100m with a cable of 0.3mm2 or more |
NPN transistor open collector |
Orange LED (lights up when output is ON) |
0~1.3mm |
20% or less of operating distance (with standard sensing object) |
1.6mm±8% |
400Hz |
Approximately 15g |
Body: PBT, indicator light section: polycarbonate/polyester |
Within ±8% of the sensing distance at +23℃ within the operating ambient temperature range |
Within ±2% with fluctuations of +10%/-15% of the power supply voltage used |
Iron 12×12×t1mm |
15mA or less |
Detection axis direction, direction perpendicular to the detection axis: 0.04mm or less |
-25~+70℃, Storage: -40~+85℃ |
35~85%RH, during storage: 35~95%RH |
IP68 (IEC), IP68G |
50MΩ or more at DC500V megger, between all charging parts and case |
Durability 10~500Hz Double amplitude 3mm (MAX.20G) 2 hours each in XYZ directions |
Durability 10,000m/s2 (approximately 1,000G) 3 times in each direction of XYZ |
AC1,000V for 1 minute, all live parts and between cases |
CE marking (EMC directive, RoHS directive), UKCA marking (EMC regulation, RoHS regulation) |
12~24V DC +10/-15% Ripple P-P 10% or less |