All Categories

History

FA sensor Light curtain/safety equipment Safety light curtain dedicated control unit SF-C10-SF-C11
FA sensor Light curtain/safety equipment Safety light curtain dedicated control unit SF-C10-Panasonic Industry Co., Ltd.

FA sensor Light curtain/safety equipment Safety light curtain dedicated control unit SF-C10
Panasonic Industry Co., Ltd.


About This Product

basic information

■Reduced safety circuit construction time

・Acquired UL/C-UL, CE, TUV, UKCA. (CE: Machinery Directive, EMC Directive UKCA: Machinery Regulation, EMC Regulation UL: Listing Certification) ・Product that has passed the Ministry of Health, Labor and Welfare type examination ・Control category ・PLe SIL3 ・Control category: Supports up to control category 4 (Control category varies depending on contact method and control circuit.) Features

■Connector connection control unit [SF-C11]

・One-touch connection: Wiring with the safety light curtain is a one-touch connector connection. Reduces construction and replacement time. ・Easy installation with no need for torque management: Spring-type terminal blocks are used for wiring other than the safety light curtain. There is no need to manage terminal tightening torque. ・Reduced maintenance work with removable terminal block: Adopts a removable terminal block. There is no need to rewire during maintenance.

■Thin control unit [SF-C13]

・Slim design: 22.5mm thin. It can be installed even in small gaps inside the panel. - PNP/NPN bipolar support [all models]: PNP/NPN input switching is now possible in one model, contributing to the reduction of registered part numbers.

  • Product

    FA sensor Light curtain/safety equipment Safety light curtain dedicated control unit SF-C10

Share this product


40+ people viewing

Last viewed: 1 hour ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of FA sensor Light curtain/safety equipment Safety light curtain dedicated control unit SF-C10

Image Part Number Price (excluding tax) Fuse rating Operating time (auto reset/manual reset) Semiconductor auxiliary output (AUX) output operation External relay monitor function Safety output Safety output usage category Safety output Rated operating voltage Ue/ Rated operating current Ie Safety output contact protection fuse rating Safety output Contact resistance Safety output Contact material/contact Safety output Mechanical life Safety output electrical life Response time (return time) Connectable safety light curtain Polarity switching function Current consumption Falling switching function Environmental resistance Operating ambient temperature Environmental resistance Ambient humidity Environmental resistance Protective structure Indicator light interlock (INTER_LOCK) Indicator light Safety output (OUT) Indicator light error (FAULT) Indicator light Power (Ui) Auxiliary output Auxiliary output Rated operating voltage/current Auxiliary output contact protection fuse rating Overvoltage category/pollution degree Compliance regulations and certifications Power supply voltage
FA sensor Light curtain/safety equipment Safety light curtain dedicated control unit SF-C10-Part Number-SF-C11

SF-C11

Available upon quote

Built-in electronic fuse, breaking current 0.5A or more, reset when power is cut off

80ms or less/90ms or less

Linked to the auxiliary output of the safety light curtain

Equipment

NO contact x 3
(13-14, 23-24, 33-34)

AC-15, DC-13 (IEC 60947-5-1)

30V DC/6A, 230V AC/6A, resistive load
(For inductive loads, when protecting contacts)
Minimum applicable load: 10mA (at 24V DC)

6A (slow blow fuse)

100mΩ or less (initial value)

Silver tin oxide (AgSnO), self-cleaning, forced operation

More than 10 million times (opening/closing frequency 180 times/min)

100,000 times or more (opening/closing frequency 20 times/min, 230V AC/3A resistive load)

10ms or less

SF4D series

Equipment
(Positive/negative grounding can be switched with a slide switch)
Negative ground: Compatible with PNP output safety light curtain
Positive ground: NPN output safety light curtain compatible

100mA or less (excluding current consumption of safety light curtain)

Equipment

-10~+55℃ (However, no condensation or freezing), storage: -25~+70℃

30~85%RH,
Storage: 30~95%RH

Case: IP40, terminal part: IP20

Yellow LED
(Lights up when safety output is "open")

Green LED (lights up when safety output is "closed")

Yellow LED (blinks when an error occurs)

Green LED (lights up when power is applied)

Safety relay contact (NC contact) ×1 (41-42)
(Linked to safety output)

24V DC/2A,
Minimum applicable load: 10mA (at 24V DC)

2A (slow blow fuse)

II/2

CE marking (Machine Directive, EMC Directive, RoHS Directive), UKCA marking (Machine Regulation, EMC Regulation, RoHS Regulation), UL/c-UL Listing Certification, TÜV SÜD Certification

24V DC±10% Ripple P-P10% or less

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Safety Devices Products

Other products of Panasonic Industry Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Panasonic Industry Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree