All Categories

History

Equipment sensors Air quality sensors-SN-GCJA5
Equipment sensors Air quality sensors-Panasonic Industry Co., Ltd.

Equipment sensors Air quality sensors
Panasonic Industry Co., Ltd.


About This Product

■Product overview

・The sensor detects PM2.5, which cannot be seen with the naked eye. It uses a high-precision concentration conversion algorithm to numerically output mass concentration (μg/m3), making it possible to "visualize" IAQ (indoor air quality). PM2.5 sensors are also commonly called dust sensors or dust sensors. ・Highly accurate numerical display of mass concentration ・Line up of laser type

■Assumed application

・Visualization of the air purification function of air purifiers and air conditioners ・Air environment monitoring in fields such as HEMS/BEMS

■Application

・“Visualization” of the air purifying function of the air purifier. (Residential air purifier, commercial air purifier) ・“Visualization” of the air purifying function of air conditioners. (Residential air conditioners, commercial air conditioners)

■Application field

・Air environment monitoring in the field of HEMS (Home Energy Management System). ・Air environment monitoring in the BEMS (Building Energy Management System) field.

  • Product

    Equipment sensors Air quality sensors

Share this product


70+ people viewing

Last viewed: 3 hours ago


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Equipment sensors Air quality sensors

Image Part Number Price (excluding tax) Dc fan motor Size (width/depth/height) (mm) Data update interval/averaging processing time Maintenance (lens cleaning) Output Output format Operating temperature (℃) Operating power supply voltage (V) Exterior shield Life (accuracy maintenance period) Method Minimum detectable particle size (µm) Airflow control Current consumption (mA) Measurement target and accuracy: PM1.0 Measurement target and accuracy: PM10 (%) Measurement target and accuracy: PM2.5 Measurement target and accuracy: Pollen Concentration range Power (V)
Equipment sensors Air quality sensors-Part Number-SN-GCJA5

SN-GCJA5

Available upon quote

Can be

37×37×12mm

1 second/20 seconds

Unnecessary

PM1.0/2.5/10 mass concentration value (/)
By particle size (6 ranges) Number of counts (pieces)
Sensor status information

UART, I2C

-10 ~ 60

5.0 (±10%)

With shield function

5 years

Laser type

0.3

Dc fan motor

100 or less

Measurable

±10

35~1,000μg/m3 : ±10%

×

1~1,000μg/m3

5 (data output is 3.3V)

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Duct Sensors Products

Other products of Panasonic Industry Co., Ltd.

Reviews shown here are reviews of companies.


View more products of Panasonic Industry Co., Ltd.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2025 Metoree