All Categories
History
Product
Made of steel plate/no pressure open type Showa SN heater kerosene/A heavy oil/gas firingHandling Company
Showa Iron Works Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | 1 circuit specification For hot water supply only Pressure loss (kPa) | 1-circuit specification Hot water supply only Head loss (m) | 1 circuit specification, hot water supply only, maximum output (5~60℃) | 1 circuit specification Hot water supply only Hot water supply amount (5~60℃) | 1-circuit specification Hot water only Heat collection pump capacity (kW) | 2-circuit specification 2 heating circuits Pressure loss (kPa) | 2 circuit specifications Heating 2 circuits Rated output Δt=20℃ | 2-circuit specification 2 heating circuits Maximum temperature at rated temperature (℃) | 2-circuit specification 2 heating circuits Head loss (m) | 2-circuit specification 2 heating circuits Hot water circulation amount | 2 circuit specifications Heating 2 circuits Heat collection pump capacity (1 unit) | 2-circuit specification Combined heating and hot water supply Heating Pressure loss | 2-circuit specification Combined heating and hot water heating Heating head loss (m) | 2-circuit specification Combined heating and hot water heating Maximum output | 2-circuit specification Combined heating and hot water supply Hot water circulation amount | 2-circuit specification Combined heating and hot water supply Hot water supply Pressure loss | 2-circuit specification Combined heating and hot water supply Hot water head loss (m) | 2-circuit specification Combined heating and hot water supply Hot water supply Maximum output | 2-circuit specification Combined heating and hot water supply Hot water supply amount (5~60℃) | Oil burner Burner motor (2 poles) | Oil burner control method | Oil burner model | Oil burner power supply | Temporary side can water volume (L) | Heat transfer area (m2) | Output | Heat exchanger water capacity (1 bottle) | Heat exchanger material | Fuel consumption A heavy oil (L/h) | Fuel consumption Kerosene (L/h) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SN (S) (W) -1004M |
Available upon quote |
14.7 |
1.5 |
116kW, 100 (10^3kcal/hl) |
1,820 L/h |
0.25 |
27.5 |
116kW, 100 (10^3kcal/hl) |
55~75 |
2.8 |
5,000L/h |
0.25 |
65.7kPa |
6.7 |
107kW, 92 (10^3kcal/hl) |
4,600L/h |
14.7kPa |
1.5 |
116kW, 100 (10^3kcal/hl) |
1,820L/h |
0.25kW |
ON-OFF control |
RL-25D |
3 phase 200V 50/60Hz |
190 |
2.5 |
116kW, 100 (10^3kcal/hl) |
2.5L |
Stainless steel pipe |
13.4 |
14.3 |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
64.1hrs
Company Review
5.0