Class's best cost performance low noise / high -resolution oscilloscope WAVESURFER 4000HDHandling Company
Teledyne LeCroyCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Analog bandwidth@50Ω (-3db) | Standing time (10-90%) | Input channel | Vertical decomposition ability | Number of valid bits (ENOB) | Vertical noise floor 1mv/Div ~ 1V/Div | sensitivity | DC gain accuracy (DC accuracy gain component) | Channel between isolation | Offset range | Offset accuracy | Maximum input voltage | Input coupling | Input impey dance | Frequency band restriction | Rescaling | Horizontal axis -analog channel capture mode | Time -based | Time base range | Clock accuracy | Capture -Analog Channel sampling speed | Standard memory long option (4ch / 2ch) | Average number | Vertical axis, horizontal axis, capture-Digital channel WS4KHD-MSO Option only input channel | Group division of slesholds | Supreme selection of thresholds | Slateled accuracy | Vertical axis, horizontal axis, capture-Digital channel WS4KHD-MSO option only maximum input voltage | Input dynamic range | Minimum input voltage swing |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4024HD |
Available upon quote |
200 MHz |
1.75 NS |
Four |
12 -bit |
8.7 |
65μV ~ 2.7mv |
50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings) |
Full scale ± 0.5%, offset 0V |
60db |
50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V |
± (1.0% of offset value + 0.5% of full scale + 0.02% + 1 MV of maximum offset) |
50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz) |
1 mΩ: AC, DC, GND; 50 ω: DC, GND |
50 Ω: ± 2.0%; 1 mΩ: ± 2.0%, 15 PF |
20 MHz |
Electric: Bolt, ampere |
Real time, roll, average, sequence (up to 1,000 segments, minimum 1 μs dead time) |
The internal time base is common to 4 input |
500 PS/Div ~ 100 S/Div |
+ 1 ppm/year from ± 2.5ppm calibration |
2.5GS/S (4ch), 5GS/S (2ch) |
12.5 m points/25 M points |
Additional average of 1024 sweep |
16 digital, channel |
POD 2: D15 ~ D8, POD 1: D7 ~ D0 |
TTL (+1.4 V), 5 V CMOS (+2.5 V), ECL (-1.3 V) or user definition |
± (3% + 100 MV of sleshold setting value) |
± 30V peak |
± 20V |
500 MVPP |
|
4034HD |
Available upon quote |
350 MHz |
1NS |
Four |
12 -bit |
8.6 |
70μV ~ 2.9mv |
50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings) |
Full scale ± 0.5%, offset 0V |
60db@DC ~ 200MHz, 50db@200 ~ 350MHz |
50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V |
± (1.0% of offset value + 0.5% of full scale + 0.02% + 1 MV of maximum offset) |
50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz) |
1 mΩ: AC, DC, GND; 50 ω: DC, GND |
50 Ω: ± 2.0%; 1 mΩ: ± 2.0%, 15 PF |
20 MHz, 200 MHz |
Electric: Bolt, ampere |
Real time, roll, average, sequence (up to 1,000 segments, minimum 1 μs dead time) |
The internal time base is common to 4 input |
500 PS/Div ~ 100 S/Div |
+ 1 ppm/year from ± 2.5ppm calibration |
2.5GS/S (4ch), 5GS/S (2ch) |
12.5 m points/25 M points |
Additional average of 1024 sweep |
16 digital, channel |
POD 2: D15 ~ D8, POD 1: D7 ~ D0 |
TTL (+1.4 V), 5 V CMOS (+2.5 V), ECL (-1.3 V) or user definition |
± (3% + 100 MV of sleshold setting value) |
± 30V peak |
± 20V |
500 MVPP |
|
4054HD |
Available upon quote |
500 MHz |
700ps |
Four |
12 -bit |
8.5 |
90μV ~ 3.5mv |
50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings) |
Full scale ± 0.5%, offset 0V |
60db@DC ~ 200MHz, 50db@200 ~ 500MHz |
50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V |
± (1.0% of offset value + 0.5% of full scale + 0.02% + 1 MV of maximum offset) |
50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz) |
1 mΩ: AC, DC, GND; 50 ω: DC, GND |
50 Ω: ± 2.0%; 1 mΩ: ± 2.0%, 15 PF |
20 MHz, 200 MHz |
Electric: Bolt, ampere |
Real time, roll, average, sequence (up to 1,000 segments, minimum 1 μs dead time) |
The internal time base is common to 4 input |
500 PS/Div ~ 100 S/Div |
+ 1 ppm/year from ± 2.5ppm calibration |
2.5GS/S (4ch), 5GS/S (2ch) |
12.5 m points/25 M points |
Additional average of 1024 sweep |
16 digital, channel |
POD 2: D15 ~ D8, POD 1: D7 ~ D0 |
TTL (+1.4 V), 5 V CMOS (+2.5 V), ECL (-1.3 V) or user definition |
± (3% + 100 MV of sleshold setting value) |
± 30V peak |
± 20V |
500 MVPP |
|
4104HD |
Available upon quote |
1GHz |
450ps |
Four |
12 -bit |
8.3 |
125μV ~ 4.7mv |
50 Ω: 1 MV -1 V/DIV (consecutive variable variable settings), Fully Variable; 1 MΩ: 1 MV -10 V/DIV (consecutive variable settings) |
Full scale ± 0.5%, offset 0V |
60db@DC ~ 200MHz, 50db@200 ~ 500MHz, 40db@500MHz ~ 1GHz |
50 Ω: 1 MV ~ 4.95 MV: ± 1.6 V; 5 MV ~ 9.9 MV: ± 4 V, 10 MV ~ 19.8 MV: ± 8 V; 20 MV ~ 1 V: ± 10 V |
± (1.0% of offset value + 0.5% of full scale + 0.02% + 1 MV of maximum offset) |
50 Ω: 5 VRMS, ± 10V peak, 1 mΩ: 400 V Max (DC + Peak AC ≤ 10 kHz) |
1 mΩ: AC, DC, GND; 50 ω: DC, GND |
50 Ω: ± 2.0%; 1 mΩ: ± 2.0%, 15 PF |
20 MHz, 200 MHz |
Electric: Bolt, ampere |
Real time, roll, average, sequence (up to 1,000 segments, minimum 1 μs dead time) |
The internal time base is common to 4 input |
500 PS/Div ~ 100 S/Div |
+ 1 ppm/year from ± 2.5ppm calibration |
2.5GS/S (4ch), 5GS/S (2ch) |
12.5 m points/25 M points |
Additional average of 1024 sweep |
16 digital, channel |
POD 2: D15 ~ D8, POD 1: D7 ~ D0 |
TTL (+1.4 V), 5 V CMOS (+2.5 V), ECL (-1.3 V) or user definition |
± (3% + 100 MV of sleshold setting value) |
± 30V peak |
± 20V |
500 MVPP |