All Categories
History
Relatively Fast Response
Product
Achieving high -efficiency power supply wide range programable switching DC power supply SPS5061XHandling Company
Wave CrestCategories
Click on the part number for more information about each product
Image | Part Number | Price (excluding tax) | Output Channel (CH) | Ratered output voltage (v) | Ratered Output Current (a) | TOTAL RATED OUTPUT POWER (W) | Power Ratio | LINE Regulation (MV) | Load Regulation (MV) | Ripple and Noise | Ripple (PK to PK) (MV) | RMS Ripple (MV) | Voltage Programming Accuracy | Voltage Programming Resolution | VOLTAGE READBACK ACCURACY | Voltage Readback Resolution | Temperature Coofficient | Remote Compensation Voltage | Rise Time | Ratered Load | NO LOAD | Fall Time | Transment Response Time (MS) | LINE Regulation (MA) | Load Regulation (MA) | R.M.S (MA) | Current Setting Accuracy (Ma) | Current Programming Resolution | Current Readback Accuracy (MA) | Current Readback Resolution | OVP Setting Range (V) | OVP Setting Accuracy | OCP Setting Range (A) | OCP Setting Accuracy | OTP | Low AC Input Protection | LPP | RISING/FALLING VOLTAGE SLEW Rate (V/S) | Rising/Falling Current Slew Rate (A/S) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SPS5061X |
Available upon quote |
1 |
160 |
7.5 |
360 |
3.33 |
80 (from 90 ~ 132vac or 170 ~ 265vac, Consant Load) |
80 (from Noload to Full Load, Contant Input Voltage) |
(NOISE BANDWIDTH 20MHz; Ripple Bandwidth 1MHz) |
60 |
12 |
0.1%± 100 (MV) |
1MV |
0.1%± 100 (MV) |
1MV |
100ppm/° C from Ratered Output Voltage Following 30-Minute Warm-UP. |
0.6V |
10% ~ 90% of Ratered Output Voltage, Ratered Resistance Load |
100ms |
100ms |
90% ~ 10% of Ratered Output Voltage, Ratered Resistance Load |
2 (Time for Recovery to within 0.1%+10mv of ITS RATED OUTPUT AGAINST CURRENT OF 50%~ 100%.) |
12 |
12 |
15 |
0.1%± 5 |
1MA |
0.1%± 5 |
1MA |
16-176 |
± (2% of Ratered Output Voltage) |
0.75 ~ 8.25 |
± (2% of Ratered Output Current) |
Over Temperature Alarm and Shut Off Output. |
Shut Off Output. |
THE OVER POWER LIMIT IS APPROXIMATELY 105% of The Ratered Output Power. |
0.1 ~ 320 |
0.01 ~ 15.00 |
|
SPS5062X |
Available upon quote |
1 |
160 |
15 |
720 |
3.33 |
80 (from 90 ~ 132vac or 170 ~ 265vac, Consant Load) |
80 (from Noload to Full Load, Contant Input Voltage) |
(NOISE BANDWIDTH 20MHz; Ripple Bandwidth 1MHz) |
80 |
15 |
0.1%± 100 (MV) |
1MV |
0.1%± 100 (MV) |
1MV |
100ppm/° C from Ratered Output Voltage Following 30-Minute Warm-UP. |
0.6V |
10% ~ 90% of Ratered Output Voltage, Ratered Resistance Load |
100ms |
100ms |
90% ~ 10% of Ratered Output Voltage, Ratered Resistance Load |
2 (Time for Recovery to within 0.1%+10mv of ITS RATED OUTPUT AGAINST CURRENT OF 50%~ 100%.) |
19 |
19 |
30 |
0.1%± 15 |
1MA |
0.1%± 15 |
1MA |
16-176 |
± (2% of Ratered Output Voltage) |
1.5 ~ 16.5 |
± (2% of Ratered Output Current) |
Over Temperature Alarm and Shut Off Output. |
Shut Off Output. |
THE OVER POWER LIMIT IS APPROXIMATELY 105% of The Ratered Output Power. |
0.1 ~ 320 |
0.01 ~ 30.00 |
|
SPS5063X |
Available upon quote |
1 |
160 |
22.5 |
1,080 |
3.33 |
80 (from 90 ~ 132vac or 170 ~ 265vac, Consant Load) |
80 (from Noload to Full Load, Contant Input Voltage) |
(NOISE BANDWIDTH 20MHz; Ripple Bandwidth 1MHz) |
100 |
20 |
0.1%± 100 (MV) |
1MV |
0.1%± 100 (MV) |
1MV |
100ppm/° C from Ratered Output Voltage Following 30-Minute Warm-UP. |
0.6V |
10% ~ 90% of Ratered Output Voltage, Ratered Resistance Load |
100ms |
100ms |
90% ~ 10% of Ratered Output Voltage, Ratered Resistance Load |
2 (Time for Recovery to within 0.1%+10mv of ITS RATED OUTPUT AGAINST CURRENT OF 50%~ 100%.) |
26 |
26 |
45 |
0.1%± 20 |
1MA |
0.1%± 20 |
1MA |
16-176 |
± (2% of Ratered Output Voltage) |
2.25 ~ 24.75 |
± (2% of Ratered Output Current) |
Over Temperature Alarm and Shut Off Output. |
Shut Off Output. |
THE OVER POWER LIMIT IS APPROXIMATELY 105% of The Ratered Output Power. |
0.1 ~ 320 |
0.01 ~ 45.00 |
|
SPS5064X |
Available upon quote |
2 |
160 |
7.5 |
720 |
3.33 |
80 (from 90 ~ 132vac or 170 ~ 265vac, Consant Load) |
80 (from Noload to Full Load, Contant Input Voltage) |
(NOISE BANDWIDTH 20MHz; Ripple Bandwidth 1MHz) |
60 |
12 |
0.1%± 100 (MV) |
1MV |
0.1%± 100 (MV) |
1MV |
100ppm/° C from Ratered Output Voltage Following 30-Minute Warm-UP. |
0.6V |
10% ~ 90% of Ratered Output Voltage, Ratered Resistance Load |
100ms |
100ms |
90% ~ 10% of Ratered Output Voltage, Ratered Resistance Load |
2 (Time for Recovery to within 0.1%+10mv of ITS RATED OUTPUT AGAINST CURRENT OF 50%~ 100%.) |
12 |
12 |
15 |
0.1%± 5 |
1MA |
0.1%± 5 |
1MA |
16-176 |
± (2% of Ratered Output Voltage) |
0.75 ~ 8.25 |
± (2% of Ratered Output Current) |
Over Temperature Alarm and Shut Off Output. |
Shut Off Output. |
THE OVER POWER LIMIT IS APPROXIMATELY 105% of The Ratered Output Power. |
0.1 ~ 320 |
0.01 ~ 15.00 |
|
SPS5065X |
Available upon quote |
3 |
160 |
7.5 |
1,080 |
3.33 |
80 (from 90 ~ 132vac or 170 ~ 265vac, Consant Load) |
80 (from Noload to Full Load, Contant Input Voltage) |
(NOISE BANDWIDTH 20MHz; Ripple Bandwidth 1MHz) |
60 |
12 |
0.1%± 100 (MV) |
1MV |
0.1%± 100 (MV) |
1MV |
100ppm/° C from Ratered Output Voltage Following 30-Minute Warm-UP. |
0.6V |
10% ~ 90% of Ratered Output Voltage, Ratered Resistance Load |
100ms |
100ms |
90% ~ 10% of Ratered Output Voltage, Ratered Resistance Load |
2 (Time for Recovery to within 0.1%+10mv of ITS RATED OUTPUT AGAINST CURRENT OF 50%~ 100%.) |
12 |
12 |
15 |
0.1%± 5 |
1MA |
0.1%± 5 |
1MA |
16-176 |
± (2% of Ratered Output Voltage) |
0.75 ~ 8.25 |
± (2% of Ratered Output Current) |
Over Temperature Alarm and Shut Off Output. |
Shut Off Output. |
THE OVER POWER LIMIT IS APPROXIMATELY 105% of The Ratered Output Power. |
0.1 ~ 320 |
0.01 ~ 15.00 |
Click on the part number for more information about each product
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
21.4hrs
Company Review
4.5