All Categories
History
Product
AC/DC power supply for battery charging AK300W-SV-13.5Handling Company
Acon Co., Ltd.Image | Part Number | Price (excluding tax) | Overcurrent protection | Overvoltage protection | Withstand voltage | Rise time | Inrush current | Short circuit protection | Dimensions (mm) | Capacity | Constant current operation adjustment range | Safety standards | Operating temperature | Output voltage variable range | Output voltage/current | Number of outputs | Cooling method | Input voltage | Input fluctuation | Input frequency | Input leakage current | Warranty period | Retention time | Storage temperature | EMC standard |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
AK300W-SV-13.5 |
Available upon quote |
Yes (cut off, restart required) |
Yes (115~130%, cutoff, restart required) |
AC3.0kV1min (all inputs) and (all outputs) |
50mstyp. (at 100% load) |
At 115V input: 20A or less |
Yes (cut off, restart required) |
215 (width) x115 (vertical) x50 (height) |
300W |
±10% |
DesignmeetGB4943,UL60950,EN60950 |
-20~+70℃ (humidity 20~93%) |
±10% |
DC13.5V/20A |
1 |
Cooling fan |
AC85~132/170~264V selected by switch |
±0.5% or less (at 100% load) |
47~63Hz |
At 230V input: 1.0mA or less |
3 years |
20mstyp. (at 100% load) |
-20~+85℃ (humidity 20~95%) |
DesignmeetGB9254,EN55022classA |