Sensor products Non-contact oil detection sensor S-Lio H-1 modelHandling Company
Densei Comtech Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Monitor part weight | Monitor section Setting function Normal/test mode setting | Monitor section Setting function Judgment time setting | Monitor section Setting function "Seconds/Minutes" selection | Monitor section Display function Detection level display | Monitor section Display function “Alarm” display | Monitor section Display function "Abnormal" display | Monitor section Display function "In operation" display | Monitor section Display function “Testing in progress” display | Monitor unit power consumption | Monitor section External output function “Alarm” signal | Monitor section External output function "Abnormal" signal | Monitor part external dimensions | Monitor unit power supply | Monitor section Operating conditions Installation environment | Monitor section Sensor section output function Communication distance | Monitor section Sensor section output function Communication method | Sensor part weight | Sensor section setting function Sensitivity detection distance setting | Sensor section Display function Oil detection indicator | Sensor unit power consumption | Sensor part external dimensions | Sensor section Excitation light source | Sensor unit power supply | Sensor section Usage conditions Installation environment | Sensor section Conditions of use Illuminance | Sensor section Operating conditions Humidity | Sensor section Operating conditions Temperature | Sensor unit Monitor connection function Communication distance | Sensor section Monitor connection function Communication method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
H-1 model |
Available upon quote |
Approximately 1kg |
Set it to "Normal" during normal operation, and "Test" during testing. |
Select the continuation judgment time for reaction level "7" from 8 levels, and when this judgment time elapses, an alarm (oil judgment) signal will be output. |
Units of 8-level settings can be switched between "seconds" and "minutes |
Displays the strength of fluorescence reaction in the oil wavelength range in 7 levels |
Detection of oil region wavelength When the fluorescence reaction becomes strong and the reaction level remains at "7" for a certain period of time, it is determined to be oil and the light turns on. |
Lights up when an abnormality is detected by the self-diagnosis function of the monitor unit. |
Lights up when power is supplied to this device |
Lights up when the mode switch switch is set to "Test |
2.4W (12V 200mA) |
Contact output (A contact) in synchronization with the “alarm” display lighting |
Contact output (A contact) when an abnormality is detected by the self-diagnosis function of the monitor unit |
W176×H180×D56 (Unit: mm) |
DC12V |
Indoor |
Maximum 100m (Note: The included cable length is 15m) |
RS485 |
Approximately 1kg |
3-stage switching (30, 50, 80cm) |
[Off: No detection] [On: Oil detected] [Blinking: LED light source abnormality] |
4.2W (12V 350mA) |
W120×H80×D210 (Unit: mm) |
Ultraviolet LED (wavelength band 365nm) |
DC12V |
Indoor |
Illuminance received by the light receiving part: 0~200lx *In the case of insulating oil |
20~85%Rh (relative humidity) |
-10~40℃ (0~40℃ when using the included AC adapter) |
Maximum 100m (Note: The included cable length is 15m) |
RS485 |