Product
Sensor life is semi-permanent Compact 6-component gas detection alarm X-am®5600Handling Company
DrägerCategories
Product Image | Part Number | Price (excluding tax) | Alarm | Built-in memory | CE mark | Certification Japanese explosion-proof certification obtained CSA | Certification Japanese explosion-proof certification obtained IECEx | Certification Japanese explosion-proof certified ATEX | Charging time | Dimensions width x height x depth | Environmental conditions | Japanese domestic explosion proof certification | MED | Measurement performance certification | Operating time | Protection class | Pump operation | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
X-am®5600 |
Available upon quote |
・Lamp 360° ・Buzzer multi-tone (more than 90dB at a distance of 30cm) |
Can be acquired via infrared communication, over 1,000 hours (when data is recorded at 1 minute intervals for 6 component gases) | Electromagnetic compatibility (Directive 2014/30/EU) |
・Class I Division 1 Group A, B, C, D, E, F, G T.-Code T4/T3 ・A/Ex da ia IIC T4/T3 /Ga |
・IECExEx da ia I Ma ・Ex da ia IIC T4/T3 Ga |
・I M1 Ex da ia I Ma ・II 1G Ex da ia IIC T4/T3 Ga |
Less than 4 hours | 48x130x44mm |
・Temperature -20~+50℃ (-40~+50℃ for up to 15 minutes) ・Pressure 700~1,300mbar ・Relative humidity 10~95% r.h. |
Ex da ia IIC T4/T3 Ga | European Maritime Directive (Directive 2014/90/EU) |
・EN50104 O2 ・EN45544-1, EN45544-2 CO&H2S ・EN60079-29-1 Methane ~ Nonane, XXS H2 H |
~12 hours Operating time without Ex sensor is over 250 hours | IP67 | Maximum hose length 45m | 220~250g |