Ultrasonic gas detector Polytron®8900 UGLD-Polytron®8900 UGLD
Ultrasonic gas detector Polytron®8900 UGLD-Dräger

Ultrasonic gas detector Polytron®8900 UGLD
Dräger

Dräger's Response Status

Response Rate

100.0%

Response Time

2.8hours

Very Fast Response


About This Product

■Features

The Dräger Polytron 8900 UGLD gas detector is an area monitor for early detection and warning of high-pressure gas leaks in outdoor plant equipment and equipment. By analyzing the sound of gas leaks using an ultrasonic sensor, it is possible to detect gas leaks earlier than with conventional gas detectors that measure the concentration of leaked gas. Additionally, gas leaks within the target area can be detected immediately without being affected by external factors such as wind direction.

■Ultrasonic sensor method - system for early detection of gas leaks

Gas detection systems commonly used to monitor gas leaks in high-pressure gas piping and containers in plants can only detect gas leaks that occur near gas sensors. Additionally, due to the influence of external environments such as wind, general gas sensors may experience a detection delay or may not detect gas clouds. Dräger's Polytron8900 UGLD is able to detect high-pressure gas-related leaks immediately after a gas leak, without being affected by this external environment. Efficient early gas leak detection not only avoids unnecessary shutdowns but also reduces time and costs associated with overall plant operations.

■Achieve safety redundancy for gas detection systems

Dräger Polytron 8900 is the latest ultrasonic gas leak detection in the Polytron 8000 series. All gas detectors in this series have a common design and a common user interface. This common user interface reduces training and maintenance burden for users. The Polytron8900 UGLD's reliable early gas leak detection capabilities make it the ideal instrument for redundant existing flame and gas detection systems.

  • Product

    Ultrasonic gas detector Polytron®8900 UGLD

Share this product


50+ people viewing


Free
Get started with our free quotation service - no cost, no obligation.

No Phone Required
We respect your privacy. You can receive quotes without sharing your phone number.

1 Models of Ultrasonic gas detector Polytron®8900 UGLD

Image Part Number Price (excluding tax) Certification UL Certification IECEx Certification CSA Certification CE mark Housing protection class Housing weight approx. Housing Display housing Housing dimensions Height x Width x Depth Housing Sensor housing Housing cable insertion port Environmental conditions Measuring range Power consumption Target gas Power supply Relay specifications Digital signal output Display Type Sensor performance Detectable range Radius Sensor performance Minimum pressure Sensor performance Response time Sensor performance Frequency band Sensor type Analog signal output
Ultrasonic gas detector Polytron®8900 UGLD-Part Number-Polytron®8900 UGLD

Polytron®8900 UGLD

Available upon quote

・Class I
・Division 1
・Group A, B, C, D
・Class I
・Zone 1
・Group IIC
・Temperature class T4

・Ex db [ia] IIC T4/T4 Gb
・-40℃≤Ta≤+70℃
・Ex db eb [ia] IIC T4 Gb
・-40≤Ta≤+70℃ "Ex e" type

・Class I
・Division 1
・Group A, B, C, D
・Class I
・Zone 1
・Group IIC
・Temperature class T4

・ATEX (European Directive 2014/34/EU)
・Electromagnetic compatibility (European Directive 2014/30/EU)
・Low voltage (European Directive 2014/35/EU)

・NEMA 4X&7
・IP65/66/67

5.0kg

Stainless steel SS 316L

280x150x130mm

Polyamide 6

・3/4”NPT X3 for cable gland
・Or M20 X3

・Temperature -40~+70℃ (with relay)
・Pressure 700~1,300mbar
・Humidity 0~100% R.H.

・0~100% (equivalent to 55~110dB)
- Typical alarm threshold is background noise level + 10% ultrasonic sensor signal

・With relay
・Remote 100mA (24V)

·hydrogen
·methane
·ethylene
·propane
・CO2
·nitrogen
・Flammable and toxic gases such as hydrogen sulfide

・10~30V DC
・3-wire system

・2 alarm relays
・1 point failure relay
・SPDT 5A@230VAC
・5A@30VDC

HART®

Backlit graphic LCD display with 3 status LEDs (green/yellow/red)

・“Ex d” type with flameproof explosion-proof structure
・Or “Ex de” type combined with increased safety explosion-proof construction

・6.5~65 feet (2~20m) Target gas type
・Leak rate
・Due to background noise

>2bar (29psi) Methane

<3 seconds

18kHz~80kHz

PVCC-coated piezoelectric microphone with automatic self-test sound generator

・Normal operation 4~20mA
・Maintenance Constant current 3.4mA or 4mA±1mA 1Hz modulation (adjustable)
・Failure <1.2mA

Customers who viewed this product also viewed

Reviews shown here are reviews of companies.

See More Gas Sensors Products

Other products of Dräger

Reviews shown here are reviews of companies.


View more products of Dräger

About Company Handling This Product

Response Rate

100.0%


Response Time

2.8hrs

Company Overview

Dräger, established in 1889, and headquartered in Lübeck, Germany, is a manufacturer and supplier of advanced ...