Product
Flammable gas and vapor detection PointGard3200Handling Company
DrägerCategories
Product Image | Part Number | Price (excluding tax) | Electrical Data Electrical Specification Certification | Electrical data Analog signal output | Electrical data Power supply AC version | Electrical data Power supply DC model | Electrical data relay specifications | Environmental conditions Humidity | Environmental conditions Temperature Operating | Environmental conditions Temperature Storage | Environmental conditions atmospheric pressure | Function | Housing cable connection | Housing certification | Housing dimensions Height x Width x Depth | Housing installation method | Housing material | Housing protection type | Housing weight | Indicator | LCD display | Measuring range | Operation | Security | Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PointGard3200 |
Available upon quote |
・CE certification ・IEC/EN 61010-1 ・UL 61010-1 compliant |
・Normal operation 4~20mA ・Maintenance Constant current 3.4mA or 4mA ±1mA 1Hz modulation (adjustable) ・Failure<1.2mA |
・Operating voltage 100~240VAC, 50~60Hz ・Normal power 6W ・Operating current (maximum) 0.5A ・Inrush current: max. 40A at 230VAC 50Hz |
・Operating voltage 8~30VDC ・Normal power 6W ・Operating current (maximum) 2.5A |
・2 alarm relays and 1 fault relay ・SPDT contact 5A at 230VAC, 5A at 30VDC, contact resistance ・Use the push button attached to the front to reset the alarm. |
Relative humidity 0~95% non-condensing | -20~+50℃ | -20~+65℃ | 700~1,300hPa |
・Event and data logger that can record up to 35,000 times -Display warning and error messages in plain text - Prevent alarms with passwordless bump test mode ・Auto calibration mode for zero and span |
・3 cable glands ・1/2"NPT |
UL 508A/50/50E:CSA C22.2 94.1/94.2/14-13 | 255x280x120mm | Wall mounting with internal screws or optional SS mounting bracket | Glass fiber reinforced polyester (GRP) | IP66 indoor or outdoor use | 3.9kg | 3 status LEDs (green/yellow/red) |
・75mm/3” backlit graphic LCD display ・Display can be selected from red or green, alphanumeric characters |
Catalytic combustion sensor (CATEx) 0~100%LEL | Uses 3 front mounted push buttons | Separate passwords for maintenance and settings menus | Self-contained gas monitor with alarm device for monitoring flammable gases and vapors in the atmosphere |