All Categories
History
Response Rate
100.0%
Response Time
108.1hours
Product
Single Phase LED Display Slim Power Regulator SPR1 SeriesHandling Company
Autonics CorporationCategories
Image | Part Number | Price (excluding tax) | Power supply voltage | Applicable load Phase control, ON/OFF control | Applicable load cycle control | Allowable voltage fluctuation range | Setting method | Indicator light Alarm indicator light/Output indicator light/Unit indicator light | Indicator light Operation indicator light/manual control indicator light | Display method | Withstand voltage | Noise resistance | Insulation resistance | Power consumption | Function alarm | Minimum load current (PA) | Rated load current | Rated load voltage | Control phase number | Control method Phase control | Control method Cycle control | Control method | Control input Automatic (Auto) control | Control input Manual control | Output accuracy | Output range (PA) | Output leakage current | Output alarm | Cooling method | Power outage compensation | Digital input | Function |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SPR1-470NNN |
Available upon quote |
100-240VAC~ 50/60Hz |
Resistive load, inductive load |
Resistive load |
90~110% of power supply voltage |
Settings using front keys, settings via communication |
Red LED |
Green LED |
3digit 7 segment LED |
2,000VAC~ 50/60Hz for 1 minute (between input terminal and power terminal) |
Square wave noise by noise simulator (pulse width 1㎲) ±2kV |
200MΩ or more (500VDC megger) |
12 VA or less |
Overcurrent alarm, overvoltage alarm, fuse burnout alarm, SCR or higher alarm, heater burnout alarm, radiator overheat alarm |
1A |
70A |
440VAC~ |
Single phase |
General control mode |
Fixed period cycle control mode, variable period cycle control mode |
ON/OFF control |
DC4-20mA, 1-5VDC, ON/OFF contact (no voltage input), pulse voltage (5-12VDC) |
External volume (10kΩ), internal volume (output limit) |
General control: Within ±10% F.S. of rated load voltage |
Phase control: 0~98%, Cycle control: 0~100%, ON/OFF control: 0~100% |
10mArms or less |
250VAC~ 3A, 30VDC 3A, 1c resistive load |
Forced cooling (with cooling fan) |
Approximately 10 years (non-volatile semiconductor memory method) |
RUN/STOP switching, AUTO/MAN switching, RESET |
Output limit (OUT ADJ), automatic control (AUTO)/manual control (MAN) selection, control method selection, reset, SOFT START, SOFT UP/DOWN, output upper/lower limit limit, input correction, input slope correction, others |
Reviews shown here are reviews of companies.
Reviews shown here are reviews of companies.
Response Rate
100.0%
Response Time
108.1hrs