3 Phase LED Display Slim Power Regulator SPR3 SeriesHandling Company
Autonics CorporationCategories
Product Image | Part Number | Price (excluding tax) | Allowable voltage fluctuation range | Applicable load Phase control, ON/OFF control | Applicable load cycle control | Control input Automatic (Auto) control | Control input Manual control | Control method | Control method Cycle control | Control method Phase control | Control phase number | Cooling method | Digital input | Display method | Function | Function alarm | Indicator light Alarm indicator light/output indicator light/unit (indicator light | Indicator light Operation indicator light/manual control indicator light | Insulation resistance | Minimum load current (PA) | Output accuracy Constant current feedback control | Output accuracy Constant power feedback control | Output accuracy Constant voltage feedback control | Output accuracy General control | Output alarm | Output communication | Output range (PA) | Power consumption | Power supply voltage | Rated load current | Rated load voltage | Setting method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SPR3-270TFF |
Available upon quote | 90~110% of power supply voltage | Resistive load, inductive load | Resistive load | DC4-20mA, 1-5VDC, ON/OFF contact (no voltage input), pulse voltage (5-12VDC) | External volume (10kΩ), internal volume (output limit) | ON/OFF control | Fixed period cycle control mode | General control mode, constant current feedback control mode, constant voltage feedback control mode, constant power feedback control mode | 3 phase | Forced cooling (with cooling fan) | RUN/STOP switching, AUTO/MAN switching, RESET | 3digit 7 segment LED | Output limit (OUT ADJ), automatic control (AUTO)/manual control (MAN) selection, control method selection, reset, SOFT START, SOFT UP/DOWN, output upper/lower limit limit, input correction, input slope correction, others | Overcurrent alarm, overvoltage alarm, fuse burnout alarm, SCR or higher alarm, heater burnout alarm, radiator overheat alarm | Red LED | Green LED | 200MΩ or more (500VDC megger) | 1A | Within ±3% F.S. of rated load current | Within ±3% F.S. of rated load power | Within ±3% F.S. of rated load voltage | Within ±10% F.S. of rated load voltage | 250VAC~ 3A, 30VDC 3A, 1c resistive load | RS485 communication output (Modbus RTU method), maximum number of connectable units: 31 units | Phase control: 0~98%, Cycle control: 0~100%, ON/OFF control: 0~100% | 22VA or less | 100-240VAC~ 50/60Hz | 70A | 220VAC~ | Settings using front keys, settings via communication |