Flow Standard / Calibrator Flow Standard (medium pressure to high pressure compatible) FFM-400 series-FFM-200-0.80~4.00-0.10~200
Flow Standard / Calibrator Flow Standard (medium pressure to high pressure compatible) FFM-400 series-FUKUDA CO., LTD.

Flow Standard / Calibrator Flow Standard (medium pressure to high pressure compatible) FFM-400 series
FUKUDA CO., LTD.


About This Product

■What is a flow standard/calibrator? Used for daily inspection of leak testers, sensitivity confirmation, and workpiece volume measurement. ■General inspection of “leakage amount” using flow standards ・Sensitivity confirmation/periodic inspection Does the sensor show normal sensitivity when a specified leak occurs? ・Function confirmation/Daily inspection Is the air leak tester accurately determining NG products? ・Condition selection/standard determination Are the air leak tester setting conditions determined so that the specified leakage amount can be determined? Convenient for setting air leak tester conditions, checking sensor sensitivity and flow rate, and for daily inspection. This is a standard leak that is connected to the front of the tester or to a pneumatic circuit such as piping. ■What is Flow Standard? Air leak tests measure the amount of leakage by looking at changes in pressure, but pressure is greatly affected by changes in air volume, temperature, atmospheric pressure, etc. Therefore, by using the flow rate generated by the flow standard as the "leakage standard", we can connect the different physical quantities of leakage amount and pressure, give reliability to the reproducibility of pressure sensor sensitivity, and realize correct air leak testing. . There is little material deterioration due to aging, making it possible to perform safe and stable air leak tests over long periods of time, and can be used as a "standard leak" for sensor sensitivity confirmation and inspection. Manufactured based on the standard test location conditions (23℃1atm) listed in JISZ8703:1983. ■A reference device that produces a constant flow rate. - Convenient for setting air leak tester conditions, checking sensor sensitivity and flow rate, and for daily inspection. ・This is a standard leak that is used by connecting to the pneumatic circuit such as the front of the tester or piping.

  • Product

    Flow Standard / Calibrator Flow Standard (medium pressure to high pressure compatible) FFM-400 series

Share this product


20+ people viewing


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of Flow Standard / Calibrator Flow Standard (medium pressure to high pressure compatible) FFM-400 series

Product Image Part Number Price (excluding tax) Accessories External dimensions (mm) Medium used Model type Operating temperature Reproducibility Specified flow rate (mL/min) Specified pressure (kPaG) Traceability report
Flow Standard / Calibrator Flow Standard (medium pressure to high pressure compatible) FFM-400 series-Part Number-FFM-200-0.80~4.00-0.10~200

FFM-200-0.80~4.00-0.10~200

Available upon quote Sealing plug, cap, instruction manual, storage box, inspection report, 2 couplings (1 each for inlet and outlet sides) Hex17×L100 Clean air (equivalent to JISB8392-1:2012 compressed air cleanliness class 1, 3, 1) For high pressure (0.8~5.00MPaG) 23℃±3℃ ±10% of the measured flow rate (at an ambient temperature of 23°C and 1 atm) However, if the measured flow rate is 1.0 mL/min or less, the measured flow rate is within ±0.1 mL/min. 0.10~200 0.80~4.00 Traceability system diagram

Customers who viewed this product also viewed

Other products of FUKUDA CO., LTD.


View more products of FUKUDA CO., LTD.

About Company Handling This Product

This is the version of our website addressed to speakers of English in the United States. If you are a resident of another country, please select the appropriate version of Metoree for your country in the drop-down menu.

Copyright © 2024 Metoree