All Categories
History
Product
Power MonitorHandling Company
Profitet Co., Ltd.Image | Part Number | Price (excluding tax) | Weight | Environmental conditions Humidity | Environmental conditions Operating temperature | Measurement parameters Relaxation time | Measurement parameters Accuracy | Measurement parameters Irradiation time | Measurement parameters Wavelength range | Measurement parameters Maximum power density | Measurement parameters Reproducibility | Measurement parameters Entrance aperture | Measurement parameters Power range | Utility power supply | Utility Minimum Air Pressure | Utility Maximum water pressure | Utility Max Air Pressure | Utility compressed air | Utility cooling water flow rate | Utility cooling water stability | Communication interface | L×W×H (including connector) | Mount for FocusMonitor |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
PM+ HP15 |
Available upon quote |
10kg |
10~80% |
10~40℃ |
15 seconds |
±2% |
Continuous irradiation |
800-1,100nm, 10,600nm |
15kW/cm² |
±1% |
48mm |
800W~15kW |
24V DC±5%, max0.5A |
2bar |
6.5bar |
3bar |
For shutter |
5L/min |
<1K/min |
Serial |
354×243×125mm |
Option |