Product
LABO Laboratory Equipment Total Nitrogen Automatic Measuring DeviceHandling Company
Anatec Yanaco Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Air source | Carrier gas | Detector | Display | External dimensions | Ground | Installation space | Mass | Measurement method | Measurement period | Measuring range | Number of measurements | Power consumption | Power supply | Pyrolysis furnace | Repeatability (with standard solution) | Sample injection method | Saved data (internal memory) | USB memory | Washing water | Water removal | Weighing method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TN-3100P (M specification) |
Available upon quote |
Pressure: 0.4~0.9MPa (Do not contain oil or water droplets) Usage amount: Approximately 5L/min *There should be no large dew point changes. 5℃ or more at dew point under atmospheric pressure |
Instrument air (purified in equipment) | Normal pressure chemiluminescence detector | 10.4 inch LCD display | (W) 650× (D) 500× (H) 600mm (excluding top slide valve and rear regulator) | Class D grounding (separate from power grounding) | Approximately 1m of maintenance space is required in the front and approximately 0.6m on the left surface. | Approximately 70kg | Catalytic pyrolysis/chemiluminescence method (normal pressure method) |
For one measurement: Approximately 6 minutes For two measurements: Approximately 9 minutes For 3 measurements: Approximately 12 minutes For 4 measurements: Approximately 15 minutes *The following time will be added due to the addition of settings. Co-washing process: about 6 minutes Cleaning after measurement: Approximately 4 minutes |
0~20, 200mg/L optional selection type | Number of measurements per sample: 1~4 times | Approximately 700VA (at maximum load) | AC100V±10% 50/60Hz (Built-in earth leakage breaker) | Dry combustion furnace (setting 750~800℃) | CV within 3% | Intermittent injection type with slide valve |
As measured 100 times a day, Measurement data: Approximately 30 days (approximately 3000 times) Curve data: Approximately 30 days (approximately 3000 times) Alarm history data: Latest 10 items |
Calibration data, measurement data, and waveform data stored in internal memory can be recorded to USB memory. *Not all USB memory devices can be used. *Please note that the USB memory is the responsibility of the customer. |
Ion exchange water or pure water Usage amount: Approximately 10mL/1 wash (Comes with a 2L tank for cleaning water as standard) |
Dehumidification type using membrane dehumidifier | Syringe pump |