Product
AQUA water quality measuring device cyanide ion automatic measuring device CN-180Handling Company
Anatec Yanaco Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Automatic calibration mechanism | Dilution/washing water conditions | Display | Electrode cleaning | External dimensions | Ground | Installation space | Mass | Measurement method | Measurement period | Measurement target | Measuring range | Number of samples | Piping diameter | Power consumption | Power supply | Printed content | Printing method | Proofreading | Reagent replenishment | Repeatability | Sample conditions | Sample/reagent measurement | Saved data * |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CN-180 |
Available upon quote |
Calibration is performed by introducing CAL-L calibration solution, and CAL-H calibration is confirmed by automatic shift. (Standard equipped: You can choose whether to use it or not) |
Tap water or purified water (for dilution measurements, use ion exchange water or pure water) Water temperature: 2~35℃ Pressure: 0.1~0.2MPa Usage amount: Approximately 1L/measurement |
5.7 inch touch panel LCD display Display: time, measurement status, daily report, settings, cyan recovery curve history, alarm history, etc. |
Introduce cleaning water into the measurement tank and stir for cleaning. | (W) 600 × (D) 600 × (H) 1,600mm (channel base type) | Class D grounding (separate from power grounding) | Approximately 1m of maintenance space is required at the front and approximately 0.6m at the rear. | Approximately 135kg | Alkaline conditions/cyanide ion electrode method |
Shortest measurement cycle: approximately 15 minutes Repeat measurements, arbitrary measurements, and measurement starts using external contact signals are also possible. |
Free cyanide, etc. in water | 0~1 to 0~3mg/L (effective measurement range: 0.03mg/L) *Others can be manufactured | 1 sample (2 or more samples available as an option) |
Tap water inlet: Rp1/2 (valve socket nominal diameter 13) Drainage outlet: Rp1 (valve socket nominal diameter 25) Sample intake port: Rc1/8 (attached union) |
Approximately 100VA (at maximum load) *Excluding use of service outlet | AC100V±10% 50/60Hz (built-in earth leakage breaker) |
Setting value, measured value, measured value bar graph, calibration value, daily report, power off, Various alarms/individual mark printing of abnormal locations, etc. (forward/reverse order printing selectable) |
Thermal printer thermal paper (paper width 60mm) (automatic winding mechanism standard equipment) | Measure the standard solution in the CAL process and key in the printed value for calibration. |
Continuous measurement is possible for 14 days without reagent replenishment with a measurement cycle of 1 hour. (1 month specification also available *Confirmation of installation environment etc. is required) |
±3% of full scale (as equal division of logarithmic output with standard solution) (±4% of full scale for diluted measurements) |
Water temperature: 2~40℃ Pressure: 0.02~0.05MPa Flow rate: 1~5L/min |
Negative pressure suction metering method (including metering discharge method) |
Measurement data: Approximately 6 months Potential history data: Approximately 1 month Alarm history data: Latest 10 items *This is the recordable period when the measurement interval is set to 1 hour. |