AQUA water quality measuring device cyanide ion automatic measuring device CN-180Handling Company
Anatec Yanaco Co., Ltd.Categories
Image | Part Number | Price (excluding tax) | Power supply | Electrode cleaning | Piping diameter | Mass | Reagent replenishment | Sample conditions | Sample/reagent measurement | Installation space | Automatic calibration mechanism | Repeatability | Measuring range | Measurement method | Measurement target | Measurement period | Power consumption | Number of samples | Proofreading | Ground | Dilution/washing water conditions | External dimensions | Printing method | Printed content | Saved data * | Display |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CN-180 |
Available upon quote |
AC100V±10% 50/60Hz (built-in earth leakage breaker) |
Introduce cleaning water into the measurement tank and stir for cleaning. |
Tap water inlet: Rp1/2 (valve socket nominal diameter 13) |
Approximately 135kg |
Continuous measurement is possible for 14 days without reagent replenishment with a measurement cycle of 1 hour. |
Water temperature: 2~40℃ |
Negative pressure suction metering method (including metering discharge method) |
Approximately 1m of maintenance space is required at the front and approximately 0.6m at the rear. |
Calibration is performed by introducing CAL-L calibration solution, and CAL-H calibration is confirmed by automatic shift. |
±3% of full scale (as equal division of logarithmic output with standard solution) |
0~1 to 0~3mg/L (effective measurement range: 0.03mg/L) *Others can be manufactured |
Alkaline conditions/cyanide ion electrode method |
Free cyanide, etc. in water |
Shortest measurement cycle: approximately 15 minutes |
Approximately 100VA (at maximum load) *Excluding use of service outlet |
1 sample (2 or more samples available as an option) |
Measure the standard solution in the CAL process and key in the printed value for calibration. |
Class D grounding (separate from power grounding) |
Tap water or purified water (for dilution measurements, use ion exchange water or pure water) |
(W) 600 × (D) 600 × (H) 1,600mm (channel base type) |
Thermal printer thermal paper (paper width 60mm) (automatic winding mechanism standard equipment) |
Setting value, measured value, measured value bar graph, calibration value, daily report, power off, |
Measurement data: Approximately 6 months |
5.7 inch touch panel LCD display |