AQUA water quality measuring device total nitrogen automatic measuring device TN-310-TN-310
AQUA water quality measuring device total nitrogen automatic measuring device TN-310-Anatec Yanaco Co., Ltd.

AQUA water quality measuring device total nitrogen automatic measuring device TN-310
Anatec Yanaco Co., Ltd.


About This Product

The automatic total nitrogen measurement device is a fully automated version of the total nitrogen measurement method using the "catalytic pyrolysis/chemiluminescence method" adopted in JIS K0102. A measurement cycle of several minutes is possible, and it can be used in a wide range of applications, from nitrogen treatment control measurement to effluent water measurement. ■Features ・Total nitrogen measurement is possible for a wide variety of samples. ・Highly accurate and highly reproducible measurements are possible ・Supports multi-series measurement ・Negative pressure suction method is used for sample water collection. ■External input/output 1) Measured value voltage output DC0.000~1.000V within ±0.005V (non-insulated) 2) Measured value current output DC4.00~20.00mA±0.08mA (isolated) 3) Alarm contact output No-voltage A contact output (1A or less when contact capacity is 30V DC) (Changing to b contact…optional) 1.Concentration upper limit alarm 2.Sample...Option 3.Cleaning water cutoff 4. Instrument abnormality 5. Power off 6. Under maintenance 4) External start input No-voltage A contact input (1 second or more) ■Installation conditions ・Indoor installation (installed in a building as close as possible to the water sampling point, avoiding direct sunlight) ・Temperature: 2~40℃ (below 30℃, temperature control with air conditioner recommended) ・Humidity: 85%RH or less ・Vibration: General factory level ・Atmosphere: A place where there is no risk of corrosive gases (H2S / SO2 / NH3 / CL2, etc.) or sea breeze coming in directly, and where there is little dust. ■Piping diameter ・Tap water inlet: Rp1/2 (valve socket nominal diameter 13) ・Drainage outlet: Rp1 (valve socket nominal diameter 25) ・Sample intake: Rc1/8 (attached union) ・Air inlet: Φ6 (Φ4/Φ6 pipe) ・Exhaust port: Rc1/8 (Φ6/Φ8 pipe)

  • Product

    AQUA water quality measuring device total nitrogen automatic measuring device TN-310

Share this product


20+ people viewing

Last viewed: 20 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of AQUA water quality measuring device total nitrogen automatic measuring device TN-310

Product Image Part Number Price (excluding tax) Air conditions Carrier gas Detector Dilution/washing water conditions Display External dimensions Ground Installation space Mass Measurement method Measurement period Measuring range Number of samples Power consumption Power supply Printed content Printing method Proofreading Pyrolysis furnace Repeatability (with standard solution) Sample conditions Saved data * (internal memory) Washing Water removal Weighing method
AQUA water quality measuring device total nitrogen automatic measuring device TN-310-Part Number-TN-310

TN-310

Available upon quote Pressure: 0.4~0.9MPa (Do not contain oil or water droplets)
Usage amount: Approximately 5L/min
Instrument air (purified in equipment) Normal pressure chemiluminescence detector Tap water or purified water (for dilution measurements, use ion exchange water or pure water)
Water temperature: 2~35℃
Pressure: 0.1~0.7MPa
Usage amount: Approximately 500mL/measurement (when set to perform cleaning after each measurement)
7 inch touch panel LCD display
Display: time, measurement status, daily report, settings, light intensity history, alarm history, etc.
(W) 700 × (D) 600 × (H) 1,600mm (channel base type) Class D grounding (separate from power grounding) Approximately 1m of maintenance space is required at the front and approximately 0.6m at the rear.
Approximately 160kg Catalytic pyrolysis/chemiluminescence method Shortest measurement cycle: Approx. 10 minutes (excluding cleaning time)
Repeat measurements, arbitrary measurements, and measurement starts using external contact signals are also possible.
Range specified from 0 to 20 to 1,000mg/L *Others can be manufactured 1 sample (2 or more samples available as an option) Approximately 1KVA (at maximum load) AC100V±10% 50/60Hz (built-in earth leakage breaker) Setting value, measured value, measured value bar graph, calibration value, daily report, power off,
Various alarms/individual mark printing of abnormal locations, etc. (forward/reverse order printing selectable)
Thermal printer thermal paper (paper width 58mm) (automatic winding mechanism standard equipment) Set the operation mode to calibration, measure the standard solution, and set the calibration result by key input. Dry combustion furnace (setting 850℃) Full scale ±4%
(0~20mg/L or less or in case of diluted measurement, ±5% of full scale)
Water temperature: 2~40℃
Pressure: 0.02~0.05MPa
Flow rate: 1~5L/min
Measurement data: Approximately 6 months
Light amount history data: Approximately 1 month
Alarm history data: Latest 10 items
*This is the recordable period when the measurement interval is set to 1 hour.
A method of cleaning the inside of the flow path, drip pipe, catalyst, etc. using cleaning water. Electronic cooling dehumidifier Negative pressure suction metering and slide valve metering method