Product
AQUA Water quality measuring equipment Total phosphorus/total nitrogen automatic measuring deviceHandling Company
Anatec Yanaco Co., Ltd.Categories
Product Image | Part Number | Price (excluding tax) | Absorption photometry | Control method | Dilution/washing water conditions * | Display | External dimensions | Ground | Installation conditions | Installation space | Mass | Measurement method | Measurement period | Piping diameter | Power consumption | Power supply | Printed content | Printing method | Reaction cell | Reagent replenishment | Sample conditions | Sample water/reagent measurement | Saved data | Thermal decomposition method |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TPN-580 |
Available upon quote | Special interference filter, automatic drift correction with two optical paths | Computer control |
Purified water such as pure water Water temperature: 2~35℃ Pressure: 0.1~0.2MPa Usage amount: Approximately 1L/measurement *Does not contain phosphorus or nitrogen compounds (TP: 0.02mg/L or less, TN: 0.1mg/L or less) |
5.7 inch touch panel LCD display Display: time, measurement status, daily report, settings, light intensity history, alarm history, etc. |
(W) 700 × (D) 600 × (H) 1,600mm (channel base type) | Class D grounding (separate from power grounding) |
Indoor installation (installed in a building as close as possible to the water sampling point, avoiding direct sunlight) Temperature: 2~40℃ Humidity: 85%RH or less Vibration: General factory level Atmosphere: A place free of corrosive gases (H2S/SO2/NH3/CL2, etc.) |
1m required for maintenance space at the front and approximately 0.6m at the rear | Approximately 170kg |
Potassium peroxodisulfate decomposition - autoclave method (heated at 120℃ for 30 minutes) TP: Molybdenum blue (ascorbic acid) spectrophotometry TN: Ultraviolet spectrophotometry |
Schedule setting method (repeat measurement/arbitrary measurement) Measurement can also be started using an external start signal |
Pure water inlet: Rp1/2 (valve socket nominal diameter 13) Drainage outlet: Rp1 (valve socket nominal diameter 25) Sample inlet: Rc1/8 (attached union) |
Approximately 700VA (at maximum load) | AC100V 50/60Hz (built-in earth leakage breaker) |
Setting value, measured value, measured value bar graph, calibration value, daily report, power off, Various alarms/individual mark printing of abnormal locations, etc. (forward/reverse order printing selectable) |
Thermal printer thermal paper (paper width 60mm) (automatic winding mechanism standard equipment) | Direct transmission method | With a measurement cycle of 1 hour, continuous measurement is possible for 14 days without reagent replenishment (1 month specifications can be manufactured upon request) |
Water temperature: 2~40℃ Pressure: 0.02~0.05MPa Flow rate: 1~5L/min |
Negative pressure suction metering method (including metering discharge method) |
Measurement data: Approximately 6 months Light amount history data: Approximately 1 month Alarm history data: Latest 10 items |
Heating with a heater using a special acid-resistant and pressure-resistant container (120℃ 30 minutes) |