AQUA Water Quality Measuring Instrument Organic Pollution Concentration Meter (UV Meter) YUV-308-YUV-308
AQUA Water Quality Measuring Instrument Organic Pollution Concentration Meter (UV Meter) YUV-308-Anatec Yanaco Co., Ltd.

AQUA Water Quality Measuring Instrument Organic Pollution Concentration Meter (UV Meter) YUV-308
Anatec Yanaco Co., Ltd.


About This Product

In wide-area closed bodies of water such as Tokyo Bay, a total water quality control system using COD as an indicator has been introduced, and business establishments within designated areas are required to measure wastewater COD and flow rate as well as pollution load. It is mandatory. The YUV-308 Organic Pollution Density Meter uses a unique detection method (two wavelengths and four optical paths) to compensate for turbidity components in the sample and stains on the measurement cell due to scale, etc., while also measuring changes in the light intensity of the light source lamp. It is constantly corrected, allowing for highly reliable and stable measurements over a long period of time. In terms of maintainability, automatic rubber cleaning of the cell and calibration using a one-touch filter reduce daily maintenance. ■Features ・Long-term stable measurement is possible with 2 wavelengths and 4 optical paths. ・One-touch calibration is possible using a calibration filter. ・Equipped with a COD conversion function using Y=a+bX as standard. ■Display ・Digital display ・UV value, converted COD value (according to linear regression equation Y=a+bX setting) ・Zero and span calibration liquid ・COD conversion factor (a and b) ・Measurement value upper limit alarm level ・Cleaning cycle ・Major checkpoint signals such as U and V signals of UV spectrophotometer ■LED display ・Operating mode [MEAS., CLEAN, CAL. (zero/span)] ・Various alarms (CONC, POWER, SAMPLE, LAMP, TROUBLE, MAINT) ・For selecting digital display ■External output 1) Measured value voltage output DC0.000~1.000V within ±0.005V (non-insulated) 2) Measured value current output DC4.00~20.00mA±0.08mA (isolated)...Optional (during cleaning, hold the signal immediately before cleaning measurement) 3) Alarm contact output No-voltage a contact output (contact capacity 1A or less at 100V AC / 30V DC) (Changing to b contact…optional) 1.Concentration upper limit alarm 2. Power off 3.Sample cutting...option 4. Instrument abnormality 5.Cleaning in progress

  • Product

    AQUA Water Quality Measuring Instrument Organic Pollution Concentration Meter (UV Meter) YUV-308

Share this product


20+ people viewing

Last viewed: 20 hours ago


Free
Since our quotes are free, feel free to use our service.

No Phone Number Required
You won’t have to worry about receiving unnecessary calls.

1 Models of AQUA Water Quality Measuring Instrument Organic Pollution Concentration Meter (UV Meter) YUV-308

Product Image Part Number Price (excluding tax) Cleaning cycle Cleaning method External dimensions Ground Installation conditions Installation space Light source lamp Mass Measurement method Measurement target Measuring range Piping diameter Power consumption Power supply Proofreading Repeatability Responsiveness Sample conditions Stability
AQUA Water Quality Measuring Instrument Organic Pollution Concentration Meter (UV Meter) YUV-308-Part Number-YUV-308

YUV-308

Available upon quote 1H, 2H, 4H, 8H, 12H, 24H, and no cleaning arbitrary settings Piston-driven cleaning with rubber (W) 410 × (D) 515 × (H) 1,400mm (including sample tank) Class D grounding (separate from power grounding) Indoor installation (installed in a building as close as possible to the water sampling point, avoiding direct sunlight)
Temperature: 2~40℃
Humidity: 85%RH or less
Vibration: General factory level
Atmosphere: A place free of corrosive gases (H2S/SO2/NH3/CL2, etc.)
Approximately 1m of maintenance space is required at the front and approximately 0.6m at the rear. Ozone cut low pressure mercury lamp Approximately 50kg 2-wavelength, 4-path absorption photometry (wavelength: ultraviolet 254nm/visible light: 546nm) Organic pollutants capable of absorbing ultraviolet light in wastewater Absorbance 0.0~0.5, 0.0~1.0Abs (Φ20 cell measurement ⇒ Square 10nm cell equivalent absorbance) Sample water inlet: VP16
Cell drainage outlet: VP25
Sample water overflow outlet: VP25
Approximately 100VA (at maximum load) AC100V 50/60Hz (built-in earth leakage breaker) Zero: One-touch setting of indicated value using pure water or 4-digit key setting input
Span: One-touch setting of indicated value using calibration filter or 4-digit key setting input
Within ±2% of full scale (depending on standard solution and calibration solution) 90% response within 30 seconds Water temperature: 2~40℃
Pressure: 0.02~0.05MPa
Flow rate: 2~5L/min
Zero drift and span drift: ±2%/week of full scale